Skip to main content
QUICK REVIEW

[Paper Review] Gaia data release 1: Principles of the photometric calibration of the G band

J. M. Carrasco, D. W. Evans|Data Archiving and Networked Services (DANS)|Nov 7, 2016
Stellar, planetary, and galactic studiesPhysics and Astronomy36 references39 citations
TL;DR

This paper presents the photometric calibration framework for Gaia Data Release 1, establishing a self-consistent internal calibration using Gaia's own observations of stable sources, followed by external calibration against 94 standard photometric stars (SPSS) to link the data to absolute fluxes. The method achieves a typical photometric accuracy of 3 mmag, with no aperture losses or radiation damage corrections applied in this release due to incomplete data availability.

ABSTRACT

Context. Gaia is an ESA cornerstone mission launched on 19 December 2013 aiming to obtain the most complete and precise 3D map of our Galaxy by observing more than one billion sources. This paper is part of a series of documents explaining the data processing and its results for Gaia Data Release 1, focussing on the G band photometry. Aims. This paper describes the calibration model of the Gaia photometric passband for Gaia Data Release 1. Methods. The overall principle of splitting the process into internal and external calibrations is outlined. In the internal calibration, a self-consistent photometric system is generated. Then, the external calibration provides the link to the absolute photometric flux scales. Results. The Gaia photometric calibration pipeline explained here was applied to the first data release with good results. Details are given of the various calibration elements including the mathematical formulation of the models used and of the extraction and preparation of the required input parameters (e.g. colour terms). The external calibration in this first release provides the absolute zero point and photometric transformations from the Gaia G passband to other common photometric systems. Conclusions. This paper describes the photometric calibration implemented for the first Gaia data release and the instrumental effects taken into account. For this first release no aperture losses, radiation damage, and other second-order effects have not yet been implemented in the calibration.

Motivation & Objective

  • To establish a self-consistent internal photometric system for Gaia DR1 using only Gaia observations.
  • To link the internal flux scale to absolute physical units via external calibration using ground-based standard stars.
  • To account for instrumental variations across the focal plane, including colour-dependent passband shifts and time-dependent effects.
  • To enable users to compare Gaia DR1 photometry with existing photometric systems through zero-point and transformation corrections.
  • To lay the foundation for future data releases by identifying unmodeled effects such as aperture losses and radiation damage.

Proposed method

  • The calibration is split into internal and external phases: internal calibration builds a consistent flux scale using Gaia's own data, while external calibration anchors it to absolute fluxes.
  • Internal calibration uses grouped calibration units (CUs) based on telescope, field of view, CCD, exposure time, and AC position, with colour terms derived from BP/RP spectrophotometry.
  • A self-consistent flux scale is derived by comparing observed fluxes of stable, non-variable sources with predicted fluxes based on current calibration parameters.
  • The internal calibration model accounts for instrumental variations via colour-dependent corrections and includes both large-scale (LS) and small-scale (SS) calibration components.
  • External calibration uses 94 validated SPSS observed under photometric conditions to determine the zero point and transformations to standard photometric systems.
  • The process avoids creating separate photometric systems across magnitude ranges by ensuring sufficient mixing between calibration units and applying link calibrations where needed.

Experimental results

Research questions

  • RQ1How can a self-consistent photometric system be established for Gaia DR1 using only Gaia's own observations?
  • RQ2What instrumental effects—such as focal plane response variations and time-dependent changes—must be modeled to achieve accurate photometry?
  • RQ3How can the internal flux scale be linked to absolute physical fluxes using a minimal set of ground-based standard stars?
  • RQ4What are the key limitations in Gaia DR1’s calibration, and which effects (e.g. aperture loss, radiation damage) remain unmodeled?
  • RQ5How does the use of BP/RP spectrophotometry enable accurate colour term estimation for the G band calibration?

Key findings

  • The internal calibration achieved a self-consistent flux scale across the entire Gaia focal plane and mission duration, using millions of stable sources.
  • The external calibration successfully linked the internal system to absolute fluxes using only 94 validated SPSS, with a precision better than 1% and accuracy below 3%.
  • The final photometric accuracy reached 3 mmag, meeting the target for Gaia DR1.
  • The calibration model accounts for passband variations due to source colour, AC position, telescope, CCD row and strip, and observation time.
  • Aperture losses and radiation damage were not included in DR1 due to insufficient input data, but are planned for future releases.
  • The use of LS and SS calibration units enabled robust handling of both global and local instrumental variations, ensuring consistency across magnitude and colour ranges.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.