TL;DR

This paper proposes the GRN-Transformer, a novel deep learning model that integrates Gated Residual Networks (GRN) into the Transformer architecture to enhance motion artifact detection in pediatric intensive care unit (PICU) photoplethysmogram (PPG) signals. By improving feature extraction and mitigating overfitting in small, imbalanced datasets, the GRN-Transformer achieves 98% accuracy, 90% precision, 97% recall, and 93% F1-score—surpassing the standard Transformer and outperforming semi-supervised and supervised baselines.

ABSTRACT

This study investigates artifact detection in clinical photoplethysmogram signals using Transformer-based models. Recent findings have shown that in detecting artifacts from the Pediatric Critical Care Unit at CHU Sainte-Justine (CHUSJ), semi-supervised learning label propagation and conventional supervised machine learning (K-nearest neighbors) outperform the Transformer-based attention mechanism, particularly in limited data scenarios. However, these methods exhibit sensitivity to data volume and limited improvement with increased data availability. We propose the GRN-Transformer, an innovative model that integrates the Gated Residual Network (GRN) into the Transformer architecture to overcome these limitations. The GRN-Transformer demonstrates superior performance, achieving remarkable metrics of 98% accuracy, 90% precision, 97% recall, and 93% F1 score, clearly surpassing the Transformer's results of 95% accuracy, 85% precision, 86% recall, and 85% F1 score. By integrating the GRN, which excels at feature extraction, with the Transformer's attention mechanism, the proposed GRN-Transformer overcomes the limitations of previous methods. It achieves smoother training and validation loss, effectively mitigating overfitting and demonstrating enhanced performance in small datasets with imbalanced classes. The GRN-Transformer's potential impact on artifact detection can significantly improve the reliability and accuracy of the clinical decision support system at CHUSJ, ultimately leading to improved patient outcomes and safety. Remarkably, the proposed model stands as the pioneer in its domain, being the first of its kind to detect artifacts from PPG signals. Further research could explore its applicability to other medical domains and datasets with similar constraints.

Motivation & Objective

  • To address the challenge of poor performance by standard Transformers in detecting motion artifacts from PPG signals when training data is limited and class-imbalanced.
  • To improve model robustness and generalization in small-data scenarios common in clinical PPG signal analysis.
  • To integrate the Gated Residual Network (GRN) into the Transformer architecture to enhance feature learning and reduce overfitting.
  • To establish a new state-of-the-art model for binary artifact detection in PPG signals, particularly in clinical settings with constrained data availability.
  • To pioneer a novel deep learning architecture specifically designed for artifact detection in PPG signals, setting a foundation for future clinical applications.

Proposed method

  • The GRN-Transformer combines the self-attention mechanism of the Transformer with the Gated Residual Network (GRN) to improve feature representation and gradient flow.
  • GRN is inserted between the multi-head attention and feed-forward layers in the Transformer encoder blocks to refine input representations before attention computation.
  • The GRN uses learnable gates to selectively emphasize or suppress features, enhancing model expressiveness and reducing overfitting in low-data regimes.
  • The model is trained using supervised learning on a binary classification task: distinguishing 'artifact' from 'normal' PPG waveforms in a clinical PICU dataset from CHU Sainte-Justine.
  • Training includes data augmentation and class balancing techniques to address the inherent class imbalance in the PPG signal dataset.
  • Performance is evaluated using standard metrics: accuracy, precision, recall, and F1-score across varying training data percentages.

Experimental results

Research questions

  • RQ1Can the integration of Gated Residual Networks (GRN) into the Transformer architecture improve performance on motion artifact detection in PPG signals with limited and imbalanced data?
  • RQ2How does the GRN-Transformer compare to standard Transformers, semi-supervised label propagation, and KNN in terms of accuracy, precision, recall, and F1-score under low-data conditions?
  • RQ3Does the GRN-Transformer achieve smoother training and validation loss curves, indicating better generalization and reduced overfitting?
  • RQ4Is the GRN-Transformer the first model specifically designed for artifact detection in PPG signals, and does it set a new benchmark in this domain?
  • RQ5To what extent does GRN enhance the learning capacity of different neural network architectures (e.g., Transformer, BiLSTM, FCNN) in low-data scenarios?

Key findings

  • The GRN-Transformer achieves 98% accuracy, 90% precision, 97% recall, and 93% F1-score in detecting motion artifacts from PICU PPG signals, significantly outperforming the standard Transformer (95% accuracy, 85% precision, 86% recall, 85% F1-score).
  • The GRN-Transformer demonstrates smoother training and validation loss curves, indicating reduced overfitting and improved generalization, especially in low-data regimes.
  • The GRN-Transformer consistently outperforms semi-supervised label propagation and KNN-based methods across all evaluation metrics, even with limited labeled data.
  • The integration of GRN significantly enhances the performance of all evaluated models—especially the Transformer—under data scarcity and class imbalance, confirming its role in improving model robustness.
  • The GRN-Transformer is the first model of its kind to be specifically designed and validated for artifact detection in PPG signals, marking a novel contribution to clinical signal processing.
  • The GRN-FCNN model shows improved recall at low data percentages, while the GRN-BiLSTM achieves competitive precision and recall, indicating that GRN integration enhances diverse architectures.