[Paper Review] Hadron energy response of the ICAL detector at INO
This study investigates the hadron energy response of the ICAL detector at INO using GEANT4-based Monte Carlo simulations. It finds that the hadron energy resolution ranges from 85% at 1 GeV to 36% at 15 GeV, with hit multiplicity well described by a Vavilov distribution that approaches Gaussian at high energies.
The results of a Monte Carlo simulation study of the hadron energy response for the magnetized Iron CALorimeter detector, ICAL, proposed to be located at the India-based Neutrino Observatory (INO) is presented. Using a GEANT4 modeling of the detector ICAL, interactions of atmospheric neutrinos with target nuclei are simulated. The detector response to hadrons propagating through it is investigated using the hadron hit multiplicity in the active detector elements. The detector response to charged pions of fixed energy is studied first, followed by the average response to the hadrons produced in atmospheric neutrino interactions using events simulated with the NUANCE event generator. The shape of the hit distribution is observed to fit the Vavilov distribution, which reduces to a Gaussian at high energies. In terms of the parameters of this distribution, we present the hadron energy resolution as a function of hadron energy, and the calibration of hadron energy as a function of the hit multiplicity. The energy resolution for hadrons is found to be in the range 85% (for 1GeV) -- 36% (for 15 GeV).
Motivation & Objective
- To evaluate the hadron energy response of the ICAL detector in the context of atmospheric neutrino interactions at the India-based Neutrino Observatory.
- To characterize the detector's response to charged pions of fixed energy as a baseline for hadronic energy calibration.
- To assess the average response to hadrons produced in atmospheric neutrino interactions using the NUANCE event generator.
- To model the relationship between hadron energy and hit multiplicity in the active detector elements.
- To determine the energy resolution and calibration performance of ICAL for hadronic showers using simulated data.
Proposed method
- Simulation of atmospheric neutrino interactions with target nuclei using the NUANCE event generator.
- GEANT4-based full detector simulation of the ICAL magnetized iron calorimeter to model particle propagation and energy deposition.
- Analysis of hadron-induced hits in active detector elements to quantify hit multiplicity as a function of hadron energy.
- Fitting the hit multiplicity distribution to the Vavilov distribution to model energy response characteristics.
- Derivation of energy resolution and calibration curves from the Vavilov distribution parameters.
- Extrapolation of results to hadrons from neutrino interactions, including both charged and neutral current events.
Experimental results
Research questions
- RQ1How does the ICAL detector respond to hadrons of varying energies, particularly in the context of atmospheric neutrino interactions?
- RQ2To what extent does the hit multiplicity in ICAL's active elements correlate with the incident hadron energy?
- RQ3What is the energy resolution of ICAL for hadrons across the 1–15 GeV energy range?
- RQ4How well does the Vavilov distribution describe the hadron shower development and energy deposition in ICAL?
- RQ5Can the detector's hadron energy calibration be reliably established using hit multiplicity and Vavilov-based parametrization?
Key findings
- The hit multiplicity distribution for hadrons in ICAL is well described by the Vavilov distribution, which converges to a Gaussian at high energies.
- The hadron energy resolution in ICAL ranges from 85% at 1 GeV to 36% at 15 GeV, indicating improved performance at higher energies.
- The calibration of hadron energy based on hit multiplicity is feasible and consistent with the Vavilov distribution parameters.
- Charged pions of fixed energy show a predictable and measurable response, validating the simulation framework.
- The average response to hadrons from atmospheric neutrino interactions is accurately modeled using the NUANCE generator and GEANT4 simulation.
- The energy resolution improves significantly with increasing hadron energy, reflecting better shower containment and measurement precision at higher energies.