[Paper Review] High-Frequency radar measurements with CODARs in the region of Nice: improved calibration and performance
This paper presents a novel self-calibration technique for CODAR high-frequency radar systems that improves radial surface current accuracy by 2–3 cm/s over standard ideal or measured antenna patterns, using only recorded Doppler spectra without external calibration campaigns. The method enhances performance in the North-West Mediterranean Sea near Nice, validated with 40 drifter deployments, and enables continuous, low-cost calibration updates for coastal ocean monitoring networks.
We report on the installation and first results of one compact oceanographic radar in the region of Nice for a long-term observation of the coastal surface currents in the North-West Mediterranean Sea. We describe the specific processing and calibration techniques which were developed at the laboratory to produce high-quality radial surface current maps. In particular, we propose an original self-calibration technique of the antenna patterns, which is based on the sole analysis of the databasis and does not require any shipborne transponder or other external transmitters. The relevance of the self-calibration technique and the accuracy of inverted surface currents have been assessed with the launch of 40 drifters that remained under the radar coverage for about 10 days.
Motivation & Objective
- To improve the accuracy of high-frequency radar (HFR) surface current measurements in the coastal region of Nice, France.
- To address the challenge of antenna pattern calibration in compact HFR systems with limited azimuthal resolution and sensitivity to installation-induced distortions.
- To develop a self-calibration method that eliminates the need for external transponders or dedicated ship campaigns.
- To validate the performance of the self-calibrated radar system against in situ drifter measurements.
Proposed method
- A self-calibration technique is developed that analyzes recorded Doppler spectra to estimate and correct for deviations in antenna gain patterns from ideal responses.
- The method uses the Friedlander and Weiss array self-calibration approach, adapted to HFR data, to iteratively refine antenna pattern estimates from time-series radar data.
- The technique avoids reliance on external transmitters or shipborne transponders, enabling autonomous, periodic recalibration.
- The method is applied to CODAR SeaSonde data collected at Saint-Jean Cap Ferrat, using a 13.5 MHz frequency and 100 kHz bandwidth.
- Three antenna pattern types are compared: ideal (theoretical), measured (from a dedicated ship experiment), and self-calibrated (from data analysis).
- Radial current maps are generated using the MUSIC algorithm for direction-of-arrival estimation, with performance assessed via statistical comparison to drifter data.
Experimental results
Research questions
- RQ1Can a self-calibration technique based solely on recorded radar spectra improve HFR radial current accuracy without external calibration sources?
- RQ2How does the self-calibrated antenna pattern compare to ideal and measured patterns in terms of radial current estimation accuracy?
- RQ3What is the impact of antenna pattern calibration on the agreement between HFR-derived currents and in situ drifter measurements?
- RQ4Does the self-calibration method reduce RMSE and increase correlation coefficient (CC) relative to standard calibration approaches?
Key findings
- The self-calibrated antenna pattern reduced the root mean square error (RMSE) of radial surface current estimates by 2.3 cm/s compared to the ideal pattern, with a 13.5 cm/s RMSE versus 15.8 cm/s for the ideal pattern.
- The correlation coefficient (CC) between HFR and drifter data improved to 0.90 with the self-calibrated pattern, compared to 0.85 for the ideal pattern.
- The self-calibrated method achieved a 3 cm/s lower RMSE in the central radar coverage zone (7.3–7.9° longitude, 43.3–43.7° latitude) than both ideal and measured patterns.
- The optimal performance was achieved with the self-calibrated pattern, showing a small bearing offset (≤5°), while the measured pattern required a 10° correction.
- The self-calibration method outperformed both ideal and measured patterns in terms of RMSE and CC, demonstrating its robustness and practical value.
- The method enables continuous, low-cost recalibration without additional ship campaigns, making it ideal for long-term HFR monitoring networks.
Read this paper