[Paper Review] High-rate Generation and State Tomography of Non-Gaussian Quantum States for Ultra-fast Clock Frequency Quantum Processors
This paper demonstrates high-rate generation and quantum state tomography of broadband non-Gaussian states using an optical parametric amplifier (OPA) as both a squeezed-light source and phase-sensitive amplifier (PSA), achieving a record 0.9 MHz state generation rate—nearly three orders of magnitude faster than prior work—limited only by superconducting detector jitter, not optical or electronic bandwidth.
Quantum information processors greatly benefit from high clock frequency to fully harnessing the quantum advantages before they get washed out by the decoherence. In this pursuit, all-optical systems offer unique advantages due to their inherent 100 THz carrier frequency, permitting one to develop THz clock frequency processors. In practice, the bandwidth of the quantum light sources and the measurement devices has been limited to the MHz range and the generation rate of nonclassical states to kHz order -- a tiny fraction of what can be achieved. In this work, we go beyond this limitation by utilizing optical parametric amplifier (OPA) as a squeezed-light source and optical phase-sensitive amplifiers (PSA) to realize high-rate generation of broadband non-Gaussian states and their quantum tomography. Our state generation and measurement system consists of a 6-THz squeezed-light source, a 6-THz PSA, and a 66-GHz homodyne detector. With this system, we have successfully demonstrated non-Gaussian state generation at a 0.9 MHz rate -- almost three orders of magnitude higher than the current state-of-the-art experiments -- with a sub-nanosecond wave packet using continuous-wave laser. The performance is constrained only by the superconducting detector's jitter which currently limits the usable bandwidth of the squeezed light to 1 GHz, rather than the optical and electronic systems. Therefore, if we can overcome the limitation of the timing jitter of superconducting detector, non-Gaussian state generation and detection at GHz rate, or even THz rate, for optical quantum processors might be possible with OPAs.
Motivation & Objective
- Overcome the bottleneck in optical quantum processors caused by low generation rates and limited measurement bandwidth of non-Gaussian quantum states.
- Address the fundamental limitation imposed by superconducting detector timing jitter, which restricts usable bandwidth despite high optical system potential.
- Demonstrate a scalable, all-optical approach using OPA for both state generation and high-bandwidth measurement to enable THz clock frequency operation.
- Achieve high-fidelity quantum state tomography of non-Gaussian states under realistic loss conditions using optical preamplification via PSA.
- Pave the way for room-temperature, high-speed optical quantum computing by replacing conventional detectors with OPA-based photon number-resolving detectors.
Proposed method
- Employed a 6-THz optical parametric amplifier (OPA) as a broadband squeezed-light source to generate non-Gaussian quantum states.
- Utilized a second 6-THz OPA as a phase-sensitive amplifier (PSA) to pre-amplify the signal before detection, enabling high-bandwidth measurement.
- Integrated a 66-GHz homodyne detector to sample the amplified quadrature signal with high temporal resolution.
- Applied maximum likelihood estimation for quantum state tomography to reconstruct the density matrix and quantify Wigner function negativity.
- Used principal component analysis on quadrature data to extract the temporal wave packet shape and confirm a 1-GHz bandwidth.
- Systematically varied the pump power of the squeezer OPA to control squeezing levels and measure generation rate scaling.
Experimental results
Research questions
- RQ1Can OPA-based systems achieve non-Gaussian state generation rates significantly exceeding the current kHz-level benchmark?
- RQ2To what extent does optical preamplification via PSA improve the fidelity and robustness of quantum state tomography under high loss?
- RQ3Is the performance bottleneck in high-rate non-Gaussian state generation due to optical system bandwidth or detector timing jitter?
- RQ4Can OPA-based systems enable the generation and detection of non-Gaussian states at GHz or THz rates, approaching the theoretical limits of optical carrier frequencies?
- RQ5Can OPA-based optical preamplification preserve nonclassical features such as Wigner function negativity under realistic experimental loss conditions?
Key findings
- The system achieved a non-Gaussian state generation rate of 0.9 MHz, representing a nearly three-order-of-magnitude improvement over the current state-of-the-art.
- The temporal wave packet of the generated state had a bandwidth of 1 GHz, confirmed by spectral analysis and principal component decomposition of quadrature data.
- Wigner function negativity was observed at all pump powers, with values of −0.090 ± 0.004, −0.097 ± 0.005, −0.088 ± 0.005, and −0.066 ± 0.006 for 1 mW to 25 mW pump powers, respectively.
- Even with up to 15 dB additional loss after the PSA, Wigner function negativity persisted, and fidelity to the original state remained above 0.95 for losses up to 10 dB.
- The PSA-enabled measurement system showed significantly improved resilience to loss compared to conventional detection, with reconstructed states maintaining non-Gaussian features even at 20 dB loss.
- The results indicate that detector timing jitter—not optical or electronic bandwidth—is the primary limiting factor, suggesting that replacing superconducting detectors with OPA-based photon number-resolving detectors could enable GHz or THz rate operation.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.