[Paper Review] Hot prominence detected in the core of a Coronal Mass Ejection: III. Plasma filling factor from UVCS Lyman-$α$ and Lyman-$β$ observations
This study proposes a method to estimate the line-of-sight plasma filling factor in erupting prominences using simultaneous SOHO/LASCO-C2 (visible light) and SOHO/UVCS (ultraviolet) observations of Lyman-α and Lyman-β emissions. By combining resonant scattering and collisional excitation models with thermodynamic parameters from a 1D non-LTE radiative transfer model, the authors derive filling factors consistent with the model, showing weak sensitivity to flow velocity but stronger dependence on kinetic temperature, validating the technique for optically thin emission conditions.
This work deals with the study of an erupting prominence embedded in the core of a CME and focuses on the derivation of the prominence plasma filling factor. We explore two methods to measure the prominence plasma filling factor that are based on the combination of visible-light and ultraviolet spectroscopic observations. Theoretical relationships for resonant scattering and collisional excitation are used to evaluate the intensity of the H I Lyman-α and Lyman-β lines, in two prominence points where simultaneous and cospatial LASCO-C2 and UVCS data were available. Thermodynamic and geometrical parameters assumed for the calculation are provided by both observations and the results of a detailed 1D non-LTE radiative-transfer model of the prominence, developed in our previous work (Heinzel 2016). The filling factor is derived from the comparison between the calculated and the measured intensities of the two lines. The results are then checked against the non-LTE model in order to verify the reliability of the methods. The resulting filling factors are consistent with the model in both the prominence points when the separation of the radiative and collisional components of the total intensity, required to estimate the filling factor, is performed using both the line intensities. An exploration of the parameter space shows that the results are weakly sensitive to the plasma velocity, but they depends more strongly on the assumed kinetic temperatures. The combination of visible-light and ultraviolet Lyman-α and Lyman-β data can be used to approximately estimate the geometrical filling factor in erupting prominences, but the proposed techniques are reliable only for emission that is optically thin in the lines considered, condition that is not in general representative of prominence plasma.
Motivation & Objective
- To develop a model-dependent method for estimating the line-of-sight geometrical filling factor in erupting prominences using UV and visible-light observations.
- To test the reliability of combining Lyman-α and Lyman-β intensities with visible-light polarized brightness (pB) to infer filling factors.
- To assess the sensitivity of the method to key plasma parameters such as flow velocity and kinetic temperature.
- To validate the approach against a detailed 1D non-LTE radiative transfer model of the prominence structure.
- To provide a practical, initial-estimate tool for plasma parameters in prominences, useful for guiding more detailed modeling.
Proposed method
- Utilizes theoretical relationships for resonant scattering and collisional excitation of neutral hydrogen Lyman-α and Lyman-β lines.
- Employs observed and modeled thermodynamic and geometrical parameters: electron column density, kinetic temperature, flow velocity, chromospheric line intensities, and prominence thickness along the line of sight.
- Compares calculated Lyman-line intensities with measured UVCS and LASCO-C2 intensities to derive the filling factor via intensity ratio analysis.
- Applies two methods: one based on separating radiative and collisional line components using both Lyα and Lyβ intensities.
- Validates results against a 1D non-LTE radiative transfer model from prior work (Heinzel et al. 2016), ensuring consistency.
- Performs parameter space exploration to assess sensitivity to flow velocity and kinetic temperature, using Doppler-dimming factors and line profile assumptions.
Experimental results
Research questions
- RQ1Can the combination of UVCS Lyman-α and Lyman-β intensities with LASCO-C2 pB observations reliably estimate the prominence plasma filling factor?
- RQ2How sensitive is the derived filling factor to uncertainties in plasma flow velocity and kinetic temperature?
- RQ3To what extent do the assumptions about chromospheric line profiles and non-thermal motions affect the filling factor estimate?
- RQ4Is the method robust for optically thin emission conditions typical of prominence plasma?
- RQ5Can this approach provide a reliable initial estimate for plasma parameters to guide more detailed modeling?
Key findings
- The derived filling factors are consistent with the non-LTE model results in both prominence points when the radiative and collisional components of the Lyman-line intensities are separated using both Lyα and Lyβ data.
- The method shows only weak dependence on the assumed plasma flow velocity, with the intensity ratio F(α)/F(β) varying by less than 30% across the 100–300 km s⁻¹ velocity range.
- The filling factor estimates are more strongly dependent on the assumed kinetic temperature, which affects both collisional coefficients and ionization fractions.
- Variations in the effective temperature (related to line profile width) cause less than 15% change in filling factor, indicating low sensitivity to this parameter.
- The method is reliable only for optically thin emission, a condition not generally representative of prominence plasma, limiting its general applicability.
- The technique provides a viable first-order estimate of the filling factor and can serve as an initial guess for more detailed modeling of prominence parameters.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.