TL;DR

This paper proposes a hybrid ring design using fixed 8T superconducting magnets and rapidly cycling ±2T iron magnets to accelerate muons in a muon collider. By leveraging 200 Hz and 330 Hz ramping rates across two 2200 m rings, the system achieves 86 orbits of acceleration from 250 GeV/c to 2400 GeV/c with 82% muon survival, consuming only 4 megawatts average power through optimized stranded copper conductors and thin Metglas laminations to minimize losses.

ABSTRACT

Two 2200m radius hybrid rings of fixed superconducting magnets and iron magnets ramping at 200 Hz and 330 Hz are used to accelerate muons. Muons are given 25 GeV of RF energy per orbit. Acceleration is from 250 GeV/c to 2400 GeV/c and requires a total of 86 orbits in both rings; 82% of the muons survive. The total power consumption of the iron dipoles is 4 megawatts. Stranded copper conductors and thin Metglas laminations are used to reduce power losses.

Motivation & Objective

  • To design a cost-effective, high-efficiency muon acceleration system for a future muon collider with minimal RF cavity and magnet bore requirements.
  • To address the challenge of rapid muon acceleration while minimizing power consumption and technical complexity.
  • To achieve high muon survival rates (over 80%) despite the short muon lifetime of 2.2 μs.
  • To demonstrate feasibility of rapidly cycling iron magnets at 200–330 Hz with low eddy current and resistive losses.
  • To optimize magnet geometry and materials (e.g., Metglas, stranded copper) to reduce power dissipation in high-frequency cycling systems.

Proposed method

  • Uses two 2200 m radius hybrid rings with alternating 8T superconducting magnets and ±2T iron magnets, cycling between -2T and +2T at 200 Hz and 330 Hz respectively.
  • Employs a 25 GeV RF energy gain per orbit to accelerate muons from 250 GeV/c to 2400 GeV/c over 86 orbits.
  • Applies the sagitta formula $ S = R - \sqrt{R^2 - (\ell/2)^2} $, with $ R = p/(0.3B) $, to determine magnet bore size constraints based on field and momentum.
  • Calculates power losses using $ W = B^2/(2\mu_0) \times \text{volume} $, resistive losses via $ P = I^2R \int \cos^2(\theta) d\theta $, and eddy current losses via $ P \propto f^{1.51} B^{1.87} $ for core materials.
  • Uses stranded copper conductors and thin Metglas laminations to reduce eddy current and resistive losses in rapidly cycling iron magnets.
  • Applies the survival probability formula $ \prod_{N=1}^{86} \exp\left[ -2\pi R m / ( (250 + 25N) c \tau ) \right] $ to estimate muon survival over 86 orbits.

Experimental results

Research questions

  • RQ1Can a hybrid ring design using fixed 8T superconducting magnets and rapidly cycling ±2T iron magnets achieve efficient muon acceleration at high repetition rates?
  • RQ2What is the maximum achievable muon survival rate when accelerating from 250 GeV/c to 2400 GeV/c using 25 GeV per orbit in a 2200 m ring?
  • RQ3What power consumption levels can be achieved with rapidly cycling iron magnets using stranded copper conductors and low-hysteresis laminations like Metglas?
  • RQ4How do eddy current and resistive losses scale with frequency and field strength in iron magnet systems operating at 200–330 Hz?
  • RQ5Can the average power consumption be reduced to 4 megawatts through duty cycle optimization, even with high peak power demands?

Key findings

  • The hybrid ring design achieves 82% muon survival over 86 orbits of acceleration from 250 GeV/c to 2400 GeV/c, with 25 GeV RF gain per orbit.
  • The 250 → 1600 GeV/c ring operates at 200 Hz with 1200 magnets, while the 1600 → 2400 GeV/c ring runs at 330 Hz with 725 magnets, yielding a weighted average ramping rate of 250 Hz.
  • Total resistive and eddy current losses in the iron magnets are reduced to 9.5 kW per magnet using Metglas laminations, compared to 50.6 kW with 3% Si-Fe, enabling a total power consumption of only 4 megawatts on average.
  • Eddy current losses in Metglas are reduced to 7.9 kW per magnet, compared to 49 kW for 3% Si-Fe, due to its low coercivity and high resistivity.
  • The system consumes only 4 megawatts average power due to a 6% duty cycle, despite a peak power demand of 56 megawatts, making it feasible for continuous operation.
  • The design demonstrates that stranded copper conductors and thin Metglas laminations can reduce total losses to twice the I²R loss in copper alone, enabling high-frequency cycling with manageable thermal loads.