Skip to main content
QUICK REVIEW

[Paper Review] Imaging and quantum efficiency measurement of chromium emitters in diamond

Igor Aharonovich, Stefania Castelletto|arXiv (Cornell University)|Aug 17, 2010
Diamond and Carbon-based Materials ResearchMaterials Science4 citations
TL;DR

This study presents the first direct measurement of the quantum efficiency (QE) of single chromium color centers in diamond using imaging of emission dipole orientation and lifetime measurements at varying depths. By implanting Cr ions at controlled depths and analyzing decay rates in air vs. bulk diamond, the authors determine an average QE of 28% ± 4%, with dipoles preferentially oriented nearly orthogonal to the diamond surface, enabling efficient integration with photonic structures.

ABSTRACT

We present direct imaging of the emission pattern of individual chromium-based single photon emitters in diamond and measure their quantum efficiency. By imaging the excited state transition dipole intensity distribution in the back focal plane of high numerical aperture objective, we determined that the emission dipole is oriented nearly orthogonal to the diamond-air interface. Employing ion implantation techniques, the emitters were engineered with various proximities from the diamond-air interface. By comparing the decay rates from the single chromium emitters at different depths in the diamond crystal, an average quantum efficiency of 28% was measured.

Motivation & Objective

  • To directly measure the quantum efficiency (QE) of single chromium color centers in diamond, a critical parameter for quantum photonics applications.
  • To determine the emission dipole orientation of individual Cr centers relative to the diamond surface, which influences photon collection and integration with photonic devices.
  • To engineer emitters at controlled depths from the diamond-air interface using ion implantation to modulate their radiative environment.
  • To validate the dipole orientation and QE using comparative lifetime measurements in bulk diamond and near the surface.
  • To provide a benchmark for QE in a promising single-photon source platform, enabling optimization of diamond-based quantum devices.

Proposed method

  • Imaged the emission pattern of single Cr emitters in the back focal plane of a high-NA objective to determine dipole orientation via intensity distribution analysis.
  • Used ion implantation at 50 keV (shallow, ~25 nm depth) and 6 MeV (deep, ~1.5 µm depth) to create emitters at controlled distances from the diamond-air interface.
  • Measured excited-state lifetimes of individual emitters near the surface (1.24 ± 0.13 ns) and deep in the crystal (0.92 ± 0.09 ns) to extract the radiative enhancement factor β.
  • Applied the formula QE = k_rad / (k_rad + k_nr), where k_rad is the radiative decay rate in a homogeneous medium and k_nr is the non-radiative rate, inferred from β and lifetime data.
  • Used SRIM simulations to model ion implantation profiles and ensure non-overlapping end-of-range distributions for accurate depth control.
  • Combined dipole imaging with lifetime measurements to decouple radiative and non-radiative decay pathways and compute QE independently of prior assumptions.

Experimental results

Research questions

  • RQ1What is the intrinsic quantum efficiency of individual chromium color centers in diamond, and how does it vary with emitter depth?
  • RQ2How is the emission dipole of single Cr centers oriented relative to the diamond surface, and does this orientation affect photon collection efficiency?
  • RQ3Can the quantum efficiency of single emitters be measured directly without relying on indirect or theoretical estimates?
  • RQ4How does the dielectric environment near the diamond-air interface modify the radiative decay rate of Cr centers?
  • RQ5Can ion implantation be used to engineer the emitter's proximity to the surface to enable controlled measurement of QE?

Key findings

  • The emission dipole of chromium centers in diamond is preferentially oriented nearly orthogonal to the diamond-air interface, as confirmed by back-focal-plane imaging.
  • The average quantum efficiency of chromium emitters in bulk diamond is 28% ± 4%, measured across an ensemble of centers regardless of peak emission wavelength.
  • For individual emitters, QE values of 0.42 ± 0.06 and 0.29 ± 0.05 were measured for two distinct centers at 750 nm and 753 nm, respectively.
  • The measured reduction in excited-state lifetime for emitters near the surface (1.24 ± 0.13 ns) compared to deep in the crystal (0.92 ± 0.09 ns) confirms the influence of the dielectric environment on radiative decay.
  • The nearly orthogonal dipole orientation is advantageous for integration with photonic cavities and nanoantennas, overcoming the random orientation issue seen in NV centers.
  • The non-radiative decay rate (769 MHz) is higher than the inter-system crossing rate (5.1 MHz), indicating that non-radiative processes such as phonon coupling or ionization contribute significantly to the QE loss.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.