Skip to main content
QUICK REVIEW

[Paper Review] Impact of calibration uncertainties on Hubble constant measurements from gravitational-wave sources

Y. Huang, Hsin-Yu Chen|arXiv (Cornell University)|Apr 7, 2022
Pulsars and Gravitational Waves ResearchPhysics and Astronomy5 citations
TL;DR

This study investigates how instrumental calibration errors (CEs) in LIGO-Virgo detectors affect gravitational-wave-based Hubble constant ($H_0$) measurements using bright sirens. Simulating binary neutron star mergers at design sensitivity, it finds that while individual events remain robust against typical CEs, systematic biases accumulate when combining 40+ sources with extreme, correlated CEs, potentially excluding the true $H_0$ from the 90% credible interval.

ABSTRACT

Gravitational-wave (GW) detections of electromagnetically bright compact binary coalescences can provide an independent measurement of the Hubble constant $H_0$. In order to obtain a measurement that could help arbitrate the existing tension on $H_0$, one needs to fully understand any source of systematic biases for this approach. In this study, we aim to understand the impact of instrumental calibration errors (CEs) on the measurements of the luminosity distance, $D_L$, and the inferred $H_0$ value. We simulate binary neutron star mergers (BNSs), as detected by a network of Advanced LIGO and Advanced Virgo interferometers at their design sensitivity. We artificially add CEs equal to exceptionally large values experienced in LIGO-Virgo's third observing run (O3). We find that for individual BNSs at a network signal-to-noise ratio of 50, the systematic errors on $D_L$ - and hence $H_0$ - are still smaller than the statistical uncertainties. The biases become more significant when we combine multiple events to obtain a joint posterior on $H_0$. In the rather unrealistic case that the data around each detection is affected by the same CEs corresponding to the worst offender of O3, the true $H_0$ value would be excluded from the 90% credible interval after we combine $\sim$40 sources. If instead, 10% of the sources suffer from severe CEs, the true value of $H_0$ is included in the 90% credible interval even after 100 sources.

Motivation & Objective

  • To assess the impact of instrumental calibration errors (CEs) on luminosity distance ($D_L$) and Hubble constant ($H_0$) measurements from gravitational-wave sources.
  • To evaluate whether CEs could introduce systematic biases that compromise the precision and reliability of $H_0$ measurements using the bright siren method.
  • To determine under what conditions CEs could lead to exclusion of the true $H_0$ value from credible intervals when combining multiple gravitational-wave events.
  • To compare the performance of different calibration modeling techniques—PhysiCal and Spline—under extreme calibration error scenarios.

Proposed method

  • Simulated binary neutron star (BNS) mergers detected by a network of Advanced LIGO and Advanced Virgo interferometers at design sensitivity.
  • Injected artificially large calibration errors (CEs) matching the worst-case values observed during LIGO-Virgo's third observing run (O3).
  • Used the LALInference package to perform Bayesian parameter estimation on the simulated data, inferring $D_L$ and $H_0$ under different calibration error models.
  • Compared results from two calibration modeling approaches: PhysiCal (physics-based) and Spline (data-driven), to assess systematic differences.
  • Quantified biases in $D_L$ and $H_0$ by comparing posterior distributions under miscalibrated vs. correctly calibrated conditions.
  • Evaluated the cumulative effect of CEs across multiple events by combining posteriors and assessing coverage of the true $H_0$ value in credible intervals.

Experimental results

Research questions

  • RQ1How do extreme calibration errors affect the inferred luminosity distance ($D_L$) for individual binary neutron star (BNS) events?
  • RQ2To what extent do calibration errors bias the Hubble constant ($H_0$) measurement when analyzing a single gravitational-wave event?
  • RQ3How do systematic biases from correlated calibration errors accumulate when combining multiple BNS events to constrain $H_0$?
  • RQ4What is the impact of different calibration modeling techniques (e.g., PhysiCal vs. Spline) on $H_0$ inference under extreme calibration errors?
  • RQ5Under what conditions would the true $H_0$ value be excluded from the 90% credible interval due to unaccounted calibration errors?

Key findings

  • For individual BNS events with a network signal-to-noise ratio of 50, calibration errors cause systematic biases in $D_L$ and $H_0$ that remain smaller than statistical uncertainties.
  • When combining 40 or more sources all affected by the same extreme calibration error (worst-case O3 scenario), the true $H_0$ value is excluded from the 90% credible interval.
  • If only 10% of sources suffer from severe calibration errors, the true $H_0$ value remains within the 90% credible interval even after combining 100 events.
  • The difference in $D_L$ inference between PhysiCal and Spline calibration modeling methods is small compared to the bias introduced by extreme calibration errors.
  • The bias in $D_L$ due to calibration errors ranges from -0.8% to +1.0% across different calibration outlier scenarios, with the largest biases occurring in amplitude and phase errors.
  • The study demonstrates that while current calibration error levels are unlikely to bias individual $H_0$ measurements, they pose a significant risk to joint $H_0$ inference if unmodeled and correlated across events.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.