Skip to main content
QUICK REVIEW

[Paper Review] Improved Cosmological Constraints from SDSS redMaPPer Clusters via X-ray Follow-up of a Complete Subsample of Systems

Matthew Kirby, Eduardo Rozo|arXiv (Cornell University)|Oct 29, 2019
Stellar, planetary, and galactic studiesPhysics and Astronomy6 citations
TL;DR

This study improves cosmological constraints from SDSS redMaPPer galaxy clusters by incorporating Chandra X-ray observations of a complete sample of 30 of the richest clusters (z ∈ [0.1, 0.3]). By jointly modeling richness–mass, gas mass–mass, and cosmological parameters, it tightens constraints on Ωₘ and σ₈ by 25.5% and 29.8%, respectively, achieving agreement with Planck early-universe results.

ABSTRACT

We improve upon the cosmological constraints derived from the abundance and weak-lensing data of redMaPPer clusters detected in the Sloan Digital Sky Survey (SDSS). Specifically, we derive gas mass data using Chandra X-ray follow-up of a complete sample of the 30 richest SDSS redMaPPer clusters with $z\in[0.1,0.3]$, and use these additional data to improve upon the original analysis by Costanzi et al. (2019b). We simultaneously fit for the parameters of the richness-mass relation, the cluster gas mass-mass relation, and cosmology. By including our X-ray cluster sample in the SDSS cluster cosmology analysis, we measure $Ω_{ m m} = 0.25 \pm 0.04$ and $σ_8 = 0.85^{+0.06}_{-0.08}$. These constraints represent a 25.5% and 29.8% reduction in the size of the 68% confidence intervals of $Ω_{ m m}$ and $σ_8$ respectively, relative to the constraints published in Costanzi et al. (2019b). Our cosmological constraints are in agreement with early universe results from Planck. As a byproduct of our analysis, we also perform an independent calibration of the amplitude of the $\langle M_{ m gas}^{ m true}|M_{ m 500c} angle$ scaling relation. Our calibration is consistent with and of comparable precision to that of Mantz et al. (2016b).

Motivation & Objective

  • To improve cosmological constraints from optically selected galaxy clusters by incorporating high-fidelity X-ray gas mass measurements.
  • To reduce uncertainty in the richness–mass and gas mass–mass scaling relations through a complete, X-ray-observed sample of the 30 richest clusters in the SDSS redMaPPer catalog.
  • To enable tighter constraints on Ωₘ and σ₈ by combining optical abundance, weak lensing, and X-ray gas mass data in a joint likelihood analysis.
  • To provide an independent calibration of the true gas mass–halo mass relation, improving robustness for future cluster cosmology.

Proposed method

  • Acquired Chandra X-ray observations for 11 of the 30 richest SDSS redMaPPer clusters (z ∈ [0.1, 0.3]) to measure true gas masses (M_gas^true) within R₅₀₀c.
  • Combined these X-ray measurements with archival data to form a complete sample of 30 clusters, ensuring minimal selection bias.
  • Constructed a joint likelihood model that simultaneously fits for the richness–mass relation, the gas mass–mass relation, and cosmological parameters (Ωₘ, σ₈).
  • Applied conservative priors on the gas mass–mass relation to stabilize the inference and reduce scatter-related uncertainties.
  • Used stacked weak lensing masses to calibrate the mean richness–mass relation, with X-ray gas masses providing a low-scatter, unbiased mass proxy.
  • Performed a joint analysis with Baryon Acoustic Oscillations (BAO) data to further tighten cosmological constraints.

Experimental results

Research questions

  • RQ1How do X-ray gas mass measurements from Chandra improve cosmological constraints derived from optically selected clusters in the SDSS?
  • RQ2To what extent does including a complete, X-ray-observed sample of the richest clusters reduce uncertainty in the richness–mass and gas mass–mass scaling relations?
  • RQ3What is the impact of a low-scatter, unbiased mass proxy on the precision of cosmological parameter constraints like Ωₘ and σ₈?
  • RQ4How does the calibration of the true gas mass–halo mass relation compare to previous work, such as Mantz et al. (2016b)?
  • RQ5Can the inclusion of X-ray data in a joint optical/X-ray/BAO analysis significantly tighten constraints on Ωₘ and σ₈?

Key findings

  • The inclusion of Chandra X-ray data reduced the 68% confidence interval width for Ωₘ by 25.5% and for σ₈ by 29.8% compared to the prior analysis in Costanzi et al. (2019b).
  • The final cosmological constraints are Ωₘ = 0.25 ± 0.04 and σ₈ = 0.85⁺⁰.⁰⁶₋₀.⁰⁸, in agreement with Planck's early-universe results.
  • The amplitude of the ⟨M_gas^true|M₅₀₀c⟩ scaling relation was independently calibrated and found to be consistent with Mantz et al. (2016b), with comparable precision.
  • The width of the 68% confidence interval for the richness–mass relation parameters log M₁ and α_λ was reduced by 39.3% and 30.8%, respectively, relative to C19.
  • When combined with BAO data, the inclusion of the X-ray sample further tightened the 68% confidence interval on Ωₘ and σ₈ by 36.5% and 32.3%, respectively.
  • The analysis demonstrates that using a complete, low-scatter mass proxy (X-ray gas mass) significantly reduces cosmological posterior uncertainty, enabling tighter constraints without bias.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.