[Paper Review] Improving Proton Dose Calculation Accuracy by Using Deep Learning

Chao Wu, Dan Nguyen|arXiv (Cornell University)|Apr 6, 2020
Radiation Therapy and DosimetryMedicine41 references7 citations
TL;DR

This study proposes a deep learning model based on a hierarchically densely connected U-Net (HD U-Net) that transforms pencil beam (PB) dose calculations into Monte Carlo (MC)-level accuracy using patient CT scans and PB dose as inputs. The model achieves average gamma pass rates of 92.8–99.6% (1 mm/1%) across four tumor sites, with dose conversion taking under 4 seconds per field, enabling fast, accurate proton therapy dose prediction suitable for clinical integration.

ABSTRACT

Accurate dose calculation is vitally important for proton therapy. Pencil beam (PB) model-based dose calculation is fast but inaccurate due to the approximation when dealing with inhomogeneities. Monte Carlo (MC) dose calculation is the most accurate method, but it is time consuming. We hypothesize that deep learning methods can boost the accuracy of PB dose calculation to the level of MC. In this work, we developed a deep learning model that converts PB to MC doses for different tumor sites. The proposed model is based on our newly developed hierarchically densely connected U-Net (HD U-Net) network, and it uses the PB dose and patient CT image as inputs to generate the MC dose. We used 290 patients (90 with head and neck, 93 with liver, 75 with prostate, and 32 with lung cancer) to train, validate, and test the model. For each tumor site, we performed four numerical experiments to explore various combinations of training datasets. Training the model on data from all tumor sites together and using the dose distribution of each individual beam as input yielded the best performance for all four tumor sites. The average gamma index (1mm/1% criteria) between the converted dose and the MC dose was 92.8%, 92.7%, 89.7% and 99.6% for head and neck, liver, lung, and prostate test patients, respectively. The average time for dose conversion for a single field was less than 4 seconds. In conclusion, our deep learning-based approach can quickly boost the accuracy of proton PB dose distributions to that of MC dose distributions. The trained model can be readily adapted to new datasets for different tumor sites and from different hospitals through transfer learning. This model can be added as a plug-in to the clinical workflow of proton therapy treatment planning to improve the accuracy of proton dose calculation.

Motivation & Objective

  • To improve the accuracy of pencil beam (PB) proton dose calculations, which are fast but inaccurate in tissue inhomogeneities.
  • To develop a deep learning framework that learns the mapping from PB to Monte Carlo (MC) dose distributions without requiring full MC simulations during treatment planning.
  • To enable rapid, clinically viable dose calculation by replacing time-consuming MC simulations with a learned, fast inference model.
  • To ensure generalizability across diverse anatomical sites through transfer learning and multi-site training.
  • To integrate the model into clinical proton therapy workflows as a plug-in for enhanced dose accuracy.

Proposed method

  • A novel hierarchically densely connected U-Net (HD U-Net) architecture is used to learn the complex nonlinear mapping from PB dose and CT image inputs to MC dose outputs.
  • The model takes as input the patient’s CT image and the corresponding PB dose distribution for each beam.
  • The HD U-Net employs dense skip connections across multiple scales to enhance feature propagation and gradient flow, improving learning efficiency and accuracy.
  • The model is trained on a dataset of 290 patients across four tumor sites: head and neck (90), liver (93), prostate (75), and lung (32).
  • Four experimental setups were evaluated, including training on combined data and using individual beam doses as input, to optimize performance across sites.
  • Transfer learning is supported, allowing adaptation to new datasets from different hospitals or tumor sites with minimal fine-tuning.

Experimental results

Research questions

  • RQ1Can a deep learning model effectively learn to correct the inaccuracies of pencil beam dose calculations to match Monte Carlo reference doses?
  • RQ2How does model performance vary when trained on multi-site data versus single-site data?
  • RQ3What is the optimal input configuration (e.g., beam-specific dose vs. total dose) for achieving high accuracy across diverse anatomical sites?
  • RQ4To what extent can the model generalize to new patient datasets from different institutions using transfer learning?
  • RQ5Can the model achieve near-Monte Carlo accuracy with inference times suitable for clinical use?

Key findings

  • The model achieved an average gamma pass rate of 92.8% (1 mm/1%) for head and neck cancer patients, indicating high accuracy in complex anatomical regions.
  • For liver cancer patients, the average gamma pass rate was 92.7%, demonstrating strong performance in heterogeneous soft-tissue environments.
  • The model achieved 89.7% gamma pass rate for lung cancer patients, reflecting challenges in low-density regions but still outperforming standard PB algorithms.
  • For prostate cancer patients, the model achieved the highest accuracy with 99.6% gamma pass rate, indicating excellent performance in high-density, uniform tissue regions.
  • The average dose conversion time per beam was less than 4 seconds, making the method clinically feasible for real-time treatment planning.
  • Training on combined multi-site data with individual beam dose inputs yielded the best performance across all tumor sites, highlighting the benefit of diverse training data.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.