[Paper Review] In silico high-resolution whole lung model to predict the locally delivered dose of inhaled drugs
This study presents a high-resolution in silico whole-lung model that accurately predicts inhaled drug deposition by simulating airflow and particle transport in patient-specific airway geometries derived from HRCT scans. The model achieves strong correlation (ρ = 0.91) with in vivo SPECT/CT data across 10 clinical cases, enabling precise prediction of regional and lobar deposition fractions, including conducting airways vs. respiratory zone, with volume-normalized metrics for disease comparison.
The big crux with drug delivery to human lungs is that the delivered dose at the local site of action is unpredictable and very difficult to measure, even a posteriori. It is highly subject-specific as it depends on lung morphology, disease, breathing, and aerosol characteristics. Given these challenges, computational approaches have shown potential, but have so far failed due to fundamental methodical limitations. We present and validate a novel in silico model that enables the subject-specific prediction of local aerosol deposition throughout the entire lung. Its unprecedented spatiotemporal resolution allows to track each aerosol particle anytime during the breathing cycle, anywhere in the complete system of conducting airways and the alveolar region. Predictions are shown to be in excellent agreement with in vivo SPECT/CT data for a healthy human cohort. We further showcase the model's capabilities to represent strong heterogeneities in diseased lungs by studying an IPF patient. Finally, high computational efficiency and automated model generation and calibration ensure readiness to be applied at scale. We envision our method not only to improve inhalation therapies by informing and accelerating all stages of (pre-)clinical drug and device development, but also as a more-than-equivalent alternative to nuclear imaging of the lungs.
Motivation & Objective
- To develop a patient-specific, high-resolution computational model of the entire human lung for accurate prediction of inhaled drug deposition.
- To validate the model against high-quality in vivo SPECT/CT data from a controlled clinical study with parametric variation in particle size, breathing pattern, and carrier gas.
- To quantify deposition in anatomically distinct regions, including conducting airways and respiratory zones, using volume-normalized metrics for disease modeling.
- To enable simulation-based prediction of regional drug delivery patterns to support personalized inhaled therapy design.
Proposed method
- Patient-specific lung and airway geometries were reconstructed from high-resolution CT scans using segmentation masks from prior clinical studies.
- A recursive space-filling tree growth algorithm extended the airway tree beyond CT resolution to generate hybrid patient-specific/morphometric airway models.
- Physics-based simulations solved reduced-dimensional Navier-Stokes equations for transient airflow, incorporating lung tissue deformation via coupling with rib cage and diaphragm mechanics.
- A Lagrangian particle tracking method simulated aerosol transport and deposition, accounting for inertial impaction, sedimentation, and interception.
- Material properties of airways, alveoli, and chest wall were calibrated using in vivo imaging and spirometry data from the validation cohort.
- Deposition was quantified per lobe, airway generation, and sub-regions (conducting vs. respiratory zone), with volume-normalized deposition fractions used for comparative analysis.
Experimental results
Research questions
- RQ1Can a high-resolution, patient-specific in silico lung model accurately predict regional inhaled drug deposition across diverse breathing patterns and particle sizes?
- RQ2How well does the simulated deposition correlate with in vivo SPECT/CT measurements in healthy subjects?
- RQ3To what extent can the model distinguish between deposition in conducting airways versus respiratory zones, given the resolution limits of clinical imaging?
- RQ4How do volume-normalized deposition fractions enable meaningful comparison of drug delivery in healthy versus diseased lung regions?
- RQ5What is the predictive accuracy of the model in terms of mass fraction misattribution across different anatomical sub-domains?
Key findings
- The model achieved a Pearson correlation coefficient of ρ = 0.91 between predicted and in vivo measured deposition fractions across all 10 validation cases and 20 lung regions (left and right).
- The model predicted lobar deposition fractions with a median error of 0.025 (IQR: 0.015–0.040), indicating high precision in regional drug delivery prediction.
- Volume-normalized deposition fractions enabled reliable comparison of aerosol deposition patterns between healthy and diseased lung sub-regions, overcoming size-difference biases.
- The model successfully distinguished between conducting airway and respiratory zone deposition, with simulated CADF (conducting airway deposition fraction) showing strong correlation (ρ = 0.85) with 24-hour clearance data from scintigraphy.
- Particle deposition was quantified per airway generation, revealing that the majority of deposition occurred in the first 6–8 generations, with significant variation based on particle size and breathing pattern.
- The model demonstrated robustness across different particle sizes (MMAD: 3.1–5.7 µm) and tidal volumes (600–1000 mL), with consistent predictive performance.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.