[Paper Review] Influence of Coil Position on AC Losses of Stator Superconducting Windings of a Synchronous Machine for a 10 MW Wind Turbine
This study investigates how coil positioning and orientation within stator slots affect AC losses in high-temperature superconducting (HTS) windings of a 10 MW direct-drive synchronous wind turbine generator. Using a 2D finite element model based on the T-A formulation of Maxwell’s equations, the authors analyze electromagnetic fields and losses under rated conditions. The key finding is that a star-shaped coil configuration with optimized tape alignment reduces total AC losses by up to 80% and improves loss distribution, enabling higher operating temperatures and reduced thermal stress.
One of the main tasks during the design of a superconducting electrical machine is the estimation of losses in the superconducting coils. These losses can be decisive in such applications since they influence the cooling power requirements and the overall efficiency of the machine. In this publication, we focus on the dissipation in the stator superconducting coils of a synchronous machine for a wind turbine application. The T-A formulation of Maxwell's equations is used in a 2D finite element model to analyse the behaviour of the magnetic field around the coils and calculate losses. Particular attention is given to the position of the coils inside a slot and several coil configurations are presented. It is shown that certain coil arrangements lead to a significantly lower total loss, a more uniform loss distribution, which ultimately leads to the possibility of increasing the operating temperature.
Motivation & Objective
- To analyze and minimize AC losses in superconducting stator windings of a 10 MW direct-drive synchronous generator for wind turbines.
- To investigate how coil position and orientation within the slot influence magnetic field distribution and loss generation.
- To evaluate the impact of tape width (4 mm vs. 2 mm) and geometric slot modifications on loss reduction and thermal stress distribution.
- To determine if optimized coil arrangements can enable higher operating temperatures while maintaining efficiency and reliability.
- To provide a design strategy that reduces total losses and improves uniformity of power density dissipation in HTS coils.
Proposed method
- Employed the T-A (vector potential) formulation of Maxwell’s equations to model electromagnetic fields in a 2D finite element method (FEM) simulation.
- Used a non-linear resistivity model for HTS tapes based on the critical state model: ρHTS = Ec / Jc(B) * |J / Jc(B)|^(n-1), with Ec = 1e-4 V/m and n = 25.
- Calculated AC losses via integration of E·J over half a cycle: QHTS = (2/T) ∫∫ (E·J) dl dt over the superconducting tape.
- Applied periodic boundary conditions to model one pole pair, extrapolating results to the full machine using scaling factors.
- Simulated various coil configurations: typical racetrack, 90° rotated, top-bottom inclined, and star-shaped arrangements with 4 mm and 2 mm REBCO tapes.
- Modified slot geometry in the final configuration to better accommodate the star-shaped coil layout and reduce losses.
Experimental results
Research questions
- RQ1How does the spatial positioning and orientation of HTS coils within a stator slot affect AC losses in a superconducting generator?
- RQ2To what extent can reducing the tape width (from 4 mm to 2 mm) reduce magnetization losses under uniform perpendicular field conditions?
- RQ3Can reconfiguring the coil layout (e.g., star-shaped arrangement) reduce the perpendicular component of the magnetic field and thereby lower losses?
- RQ4How does the distribution of average power density dissipation vary across different coil configurations, and what are the implications for thermal stress?
- RQ5What is the maximum allowable operating temperature for each configuration, and can loss reduction enable higher temperature operation?
Key findings
- The star-shaped coil configuration with 4 mm REBCO tape reduced total AC losses by 80% compared to the typical racetrack arrangement, from 28 kW to 5.57 kW.
- The star configuration with 2 mm tape achieved the lowest total losses at 4.15 kW, representing a 73% reduction compared to the typical 2 mm tape configuration.
- Loss reduction through tape width reduction alone led to a 45% loss reduction in the typical configuration and 30% in the top-bottom inclined configuration, but caused uneven loss distribution.
- The star configuration provided the most uniform average power density dissipation across coils, significantly reducing localized thermal stress.
- The sensitivity analysis showed that the star configuration allows for a higher safe operating temperature due to lower and more uniformly distributed losses.
- Modifying the slot geometry to accommodate the star-shaped coil layout further improved electromagnetic performance and loss reduction.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.