[Paper Review] Infrared instrumentation for large telescopes: an alternative approach
This paper proposes WIDE, a low-cost, wide-field infrared imager for the LBT and TNG telescopes, optimized for deep imaging over 12′×12′ (LBT) and 26′×26′ (TNG) fields using broad-band J, H, K′, and 1μm filters. It also introduces AMICI, a high-efficiency, low-resolution prism spectrometer with >80% average transmission across 0.85–2.45μm, enabling full-spectrum acquisition in a single exposure—delivering VLT-class spectral quality on the TNG with a 7× time advantage.
I very briefly describe the latest generation near infrared (1-2.5 micron) instruments which are available on, or under development for `large' (D>=3.5 m) telescopes. Most of the imagers under construction are limited to relatively small fields, while the spectrometers aim at quite high resolving powers. The alternative instruments which I discuss here are - WIDE, a relatively low-cost instrument for the prime focus of LBT and/or of TNG optimized for deep imaging of very large fields (12'x12' on LBT and 26'x26' on TNG) through the 1 micron, J, H, K' broad-band filters. - AMICI, an ultra-high efficiency, low resolution disperser optimized for collecting complete 0.9-2.5 micron spectra of very faint objects. This device is mounted in NICS (the IR instrument for TNG) and should soon deliver spectra with quality comparable to that obtained with instruments on 8m class telescopes with similar integration times.
Motivation & Objective
- To address the lack of wide-field near-infrared (1–2.5 μm) imagers on large telescopes (D ≥ 3.5 m), which biases surveys against red, faint objects like high-redshift galaxies and cool brown dwarfs.
- To develop WIDE, a prime-focus infrared imager for LBT and TNG offering field-of-views of 12′×12′ and 26′×26′ respectively, enabling deep multicolor surveys of large sky areas.
- To design AMICI, a prism-based, low-resolution spectrometer with >80% average efficiency across 0.85–2.45 μm, allowing full-spectrum acquisition in a single exposure.
- To demonstrate that the combination of WIDE and AMICI can deliver survey power and spectral quality comparable to 8m-class telescopes, particularly on the TNG, despite its smaller aperture.
- To provide a cost-effective alternative to traditional grating-based spectrometers and large-format IR imagers, reducing instrument cost and complexity while improving efficiency and field coverage.
Proposed method
- WIDE employs a three-lens optical system with relaxed alignment tolerances, allowing the first lens to serve as a dewar window without special mounting, minimizing mechanical complexity and cost.
- The LBT version uses fused silica lenses with minimal chromatic aberration, achieving >80% encircled energy within one pixel across a 12′×12′ field, with only 0.5% distortion at the field edge.
- The TNG version uses less expensive, more dispersive fused silica (infrasil) glass, requiring refocusing per band but enabling a 35′×35′ field of view suitable for a 4×2048² array mosaic.
- AMICI uses a three-prism Amici mount (crown–flint–crown) with separated elements and anti-reflection coatings to achieve >80% average transmission from 0.85 to 2.45 μm, with a resolving power (RS) of ~50.
- The instrument design allows for high throughput and low spectral loss, with the prism disperser capturing the full 0.9–2.5 μm range in a single exposure, unlike grating-based systems that require multiple exposures per band.
- Cost estimates were compiled from suppliers for key components, with the 2048² detector array being the dominant cost, especially for the TNG version requiring four such arrays.
Experimental results
Research questions
- RQ1Can a low-cost, wide-field infrared imager be designed for large telescopes to overcome the current bias in deep surveys against red, faint objects?
- RQ2Can a prism-based spectrometer achieve higher efficiency and broader spectral coverage than traditional grating-based systems in the near-infrared?
- RQ3Does the combination of WIDE and AMICI on the TNG telescope enable near-infrared imaging and spectroscopy performance comparable to that of 8m-class telescopes like the VLT?
- RQ4Can relaxed optical tolerances in the WIDE design be leveraged to reduce mechanical complexity and cost without degrading image quality?
- RQ5Can the high throughput of AMICI (80% average efficiency) compensate for the TNG’s smaller aperture compared to the VLT, enabling comparable integration times for low-resolution spectroscopy?
Key findings
- WIDE on the LBT achieves a 12′×12′ field of view with >80% of the light enclosed within one pixel (0.352″) across the entire field, demonstrating excellent image quality and minimal distortion (0.5% at field edge).
- The TNG version of WIDE covers a 26′×26′ field of view, sufficient for a 4×2048² array mosaic, with image distortion of 0.5% at the field edge and 1.0% at the corners.
- The WIDE design tolerates a 0.5 mm decenter and 0.1° tilt of the first lens without degrading image quality, enabling it to function as a dewar window without specialized mounting.
- AMICI achieves an average spectral efficiency of >80% across 0.85–2.45 μm, with peaks exceeding 90%, significantly outperforming typical grating-based systems with <50% average efficiency.
- The AMICI spectrometer delivers full 0.9–2.5 μm spectra in a single exposure with 1.8× higher efficiency than the ISAAC LR mode, resulting in a net 7× time advantage on the TNG despite its smaller aperture.
- The cost of the WIDE instrument is dominated by the 2048² detector array, with the total instrument cost estimated at ~820 million Italian lire for TNG and ~770 million for LBT, excluding the array.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.