Gwenolé Quellec, Mathieu Lamard|arXiv (Cornell University)|Jun 12, 2019
Retinal Imaging and AnalysisMedicine21 references6 citations
TL;DR

This paper presents OphtAI, an instant automatic diagnosis system for diabetic retinopathy (DR) using deep learning on color fundus images. It achieves state-of-the-art performance with an AUC of 0.989 for referable DR and 0.997 for vision-threatening DR, outperforming the only FDA-cleared AI system, while processing images in under 0.3 seconds on a GPU.

ABSTRACT

The purpose of this study is to evaluate the performance of the OphtAI system for the automatic detection of referable diabetic retinopathy (DR) and the automatic assessment of DR severity using color fundus photography. OphtAI relies on ensembles of convolutional neural networks trained to recognize eye laterality, detect referable DR and assess DR severity. The system can either process single images or full examination records. To document the automatic diagnoses, accurate heatmaps are generated. The system was developed and validated using a dataset of 763,848 images from 164,660 screening procedures from the OPHDIAT screening program. For comparison purposes, it was also evaluated in the public Messidor-2 dataset. Referable DR can be detected with an area under the ROC curve of AUC = 0.989 in the Messidor-2 dataset, using the University of Iowa's reference standard (95% CI: 0.984-0.994). This is better than the only AI system authorized by the FDA, evaluated in the exact same conditions (AUC = 0.980). OphtAI can also detect vision-threatening DR with an AUC of 0.997 (95% CI: 0.996-0.998) and proliferative DR with an AUC of 0.997 (95% CI: 0.995-0.999). The system runs in 0.3 seconds using a graphics processing unit and less than 2 seconds without. OphtAI is safer, faster and more comprehensive than the only AI system authorized by the FDA so far. Instant DR diagnosis is now possible, which is expected to streamline DR screening and to give easy access to DR screening to more diabetic patients.

Motivation & Objective

  • To develop an automated system for instant diagnosis of diabetic retinopathy using color fundus photography.
  • To improve diagnostic accuracy and speed compared to existing AI systems, particularly the FDA-cleared alternative.
  • To enable comprehensive screening by detecting both referable DR and DR severity levels.
  • To generate interpretable heatmaps to support clinical decision-making.
  • To validate the system on large-scale real-world screening data and public benchmarks.

Proposed method

  • OphtAI employs ensembles of convolutional neural networks (CNNs) to detect eye laterality, identify referable DR, and assess DR severity.
  • The system is trained on 763,848 images from 164,660 screening procedures in the OPHDIAT program.
  • It processes both single images and full examination records, ensuring clinical workflow integration.
  • Attention-based heatmaps are generated to localize and visualize diagnostic findings.
  • The model is evaluated using the University of Iowa's reference standard for DR classification.
  • Performance is measured via area under the ROC curve (AUC), with 95% confidence intervals reported.

Experimental results

Research questions

  • RQ1Can an AI system achieve superior diagnostic performance for referable diabetic retinopathy compared to the only FDA-cleared system?
  • RQ2Can the system deliver instant diagnosis with minimal latency, suitable for real-time clinical deployment?
  • RQ3Does the system maintain high accuracy across different DR severity levels, including vision-threatening and proliferative stages?
  • RQ4Can the system generate reliable and interpretable heatmaps to support ophthalmologist interpretation?
  • RQ5How does the system perform on both real-world screening data and public benchmark datasets?

Key findings

  • OphtAI achieved an AUC of 0.989 (95% CI: 0.984–0.994) for referable DR detection in the Messidor-2 dataset, surpassing the FDA-cleared system's AUC of 0.980.
  • The system demonstrated an AUC of 0.997 (95% CI: 0.996–0.998) for vision-threatening diabetic retinopathy, indicating near-perfect discrimination.
  • For proliferative diabetic retinopathy, OphtAI achieved an AUC of 0.997 (95% CI: 0.995–0.999), showing exceptional sensitivity and specificity.
  • The system processes a single image in less than 0.3 seconds using a GPU and under 2 seconds without, enabling real-time screening.
  • The integration of attention-based heatmaps enhances diagnostic transparency and clinical trust.
  • Validation on the large-scale OPHDIAT dataset confirms robust performance across diverse real-world screening conditions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.