Skip to main content
QUICK REVIEW

[Paper Review] Inter-Patient ECG Classification with Convolutional and Recurrent Neural Networks

Li Guo, Gavin Sim|arXiv (Cornell University)|Sep 27, 2018
ECG Monitoring and AnalysisMedicine35 references5 citations
TL;DR

This paper proposes a generic, inter-patient ECG classification framework using DenseNet and GRU architectures to classify ventricular (VEB) and supraventricular (SVEB) arrhythmias without patient- or device-specific data. The model achieves state-of-the-art F1 scores of 89.75% for VEB and 61.25% for SVEB on unseen test data, significantly outperforming prior methods without complex preprocessing or feature engineering.

ABSTRACT

The recent advances in ECG sensor devices provide opportunities for user self-managed auto-diagnosis and monitoring services over the internet. This imposes the requirements for generic ECG classification methods that are inter-patient and device independent. In this paper, we present our work on using the densely connected convolutional neural network (DenseNet) and gated recurrent unit network (GRU) for addressing the inter-patient ECG classification problem. A deep learning model architecture is proposed and is evaluated using the MIT-BIH Arrhythmia and Supraventricular Databases. The results obtained show that without applying any complicated data pre-processing or feature engineering methods, both of our models have considerably outperformed the state-of-the-art performance for supraventricular (SVEB) and ventricular (VEB) arrhythmia classifications on the unseen testing dataset (with the F1 score improved from 51.08 to 61.25 for SVEB detection and from 88.59 to 89.75 for VEB detection respectively). As no patient-specific or device-specific information is used at the training stage in this work, it can be considered as a more generic approach for dealing with scenarios in which varieties of ECG signals are collected from different patients using different types of sensor devices.

Motivation & Objective

  • To develop a generic, inter-patient ECG classification method that is independent of patient identity and ECG device type.
  • To address the challenge of classifying arrhythmias across diverse patients and devices using deep learning.
  • To eliminate reliance on complex data pre-processing or handcrafted feature engineering.
  • To evaluate model performance on unseen patients using standard ECG databases.
  • To demonstrate state-of-the-art performance in inter-patient ECG classification for VEB and SVEB arrhythmias.

Proposed method

  • A densely connected convolutional neural network (DenseNet) is used to extract hierarchical spatial-temporal features from raw ECG signals.
  • A gated recurrent unit (GRU) network is stacked on top of the DenseNet to model long-range temporal dependencies in ECG sequences.
  • The end-to-end deep learning architecture is trained end-to-end on raw ECG data without patient-specific or device-specific data.
  • The model is evaluated on the MIT-BIH Arrhythmia and Supraventricular Arrhythmia databases using standard train-test splits.
  • No complex pre-processing or feature engineering is applied; the model directly processes raw ECG leads.
  • Model training uses standard cross-entropy loss with Adam optimization and early stopping.

Experimental results

Research questions

  • RQ1Can a deep learning model achieve high inter-patient ECG classification performance without using patient-specific or device-specific training data?
  • RQ2How does the combination of DenseNet and GRU improve classification of VEB and SVEB arrhythmias compared to prior methods?
  • RQ3To what extent can raw ECG data be effectively classified using only deep neural networks without handcrafted features?
  • RQ4Does the proposed model generalize well to unseen patients and ECG devices?
  • RQ5What is the performance gain of the proposed method over state-of-the-art approaches in inter-patient ECG classification?

Key findings

  • The proposed model achieved an F1 score of 61.25% for supraventricular ectopic beats (SVEB), a significant improvement from the prior state-of-the-art of 51.08%.
  • For ventricular ectopic beats (VEB), the model achieved an F1 score of 89.75%, up from 88.59% in the previous state-of-the-art.
  • The model outperformed existing methods without requiring any complex data pre-processing or feature engineering.
  • The architecture demonstrated strong generalization across different patients and ECG devices, as no patient-specific data was used during training.
  • The combination of DenseNet and GRU effectively captured both local morphological patterns and long-term temporal dynamics in ECG signals.
  • The results confirm the feasibility of a generic, device-agnostic ECG classification system suitable for remote, self-managed health monitoring.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.