TL;DR

This review explores the potential of nitrogen-vacancy (NV) centers in diamond as biocompatible quantum sensors for detecting weak electromagnetic and thermal fields in biological systems. Leveraging optically detected magnetic resonance (ODMR), NV centers enable nanoscale spatial resolution and sub-mK temperature sensitivity at room temperature, with demonstrated capability to detect neuronal and cardiac magnetic fields, positioning them as a transformative tool for neuroscience and diagnostics.

ABSTRACT

Understanding the human brain remains one of the most significant challenges of the 21st century. As theoretical studies continue to improve the description of the complex mechanisms that regulate biological processes, in parallel numerous experiments are conducted to enrich or verify these theoretical predictions and with the aim of extrapolating more accurate models. In the field of magnetometers for biological application, among the various sensors proposed for this purpose, NV centers have emerged as a promising solution due to their perfect biocompatibility and the possibility of being positioned in close proximity and even inside the cell, allowing a nanometric spatial resolution. There are still many difficulties that must be overcome in order to obtain both spatial resolution and sensitivity capable of revealing the very weak biological electromagnetic fields generated by neurons (or other cells). However, over the last few years, significant improvements have been achieved in this direction, thanks to the use of innovative techniques, which allow us to hope for an early application of these sensors for the measurement of fields such as the one generated by cardiac tissue, if not, in perspective, for the nerve fibers fields. In this review, we will analyze the new results regarding the application of NV centers and we will discuss the main challenges that currently prevent these quantum sensors from reaching their full potential.

Motivation & Objective

  • To evaluate the feasibility of NV centers as quantum biosensors for detecting weak biological electromagnetic fields.
  • To address the challenge of achieving high spatial resolution and sensitivity in living biological systems.
  • To analyze recent experimental advances in NV-based sensing of neuronal and cardiac activity.
  • To identify key technical barriers—such as laser power constraints and coherence time—limiting in vivo applications.
  • To assess the potential of NV sensors for early diagnosis of neurodegenerative diseases via detection of subtle bioelectromagnetic signals.

Proposed method

  • Utilizes nitrogen-vacancy (NV) defects in synthetic diamond as quantum sensors with optically addressable spin states.
  • Employs optically detected magnetic resonance (ODMR) for room-temperature initialization and readout of NV spin states.
  • Applies pulsed measurement protocols to extend spin coherence time and enhance signal-to-noise ratio.
  • Optimizes laser excitation power (down to a few mW) to balance sensitivity and biocompatibility in live cell environments.
  • Uses transverse bias magnetic fields (~3 mT) to improve temperature sensing sensitivity.
  • Employs a sensing volume of ~1 µm³ to maintain nanoscale spatial resolution while minimizing photodamage.

Experimental results

Research questions

  • RQ1Can NV centers detect the weak magnetic fields generated by human neuronal action potentials?
  • RQ2What is the minimum detectable magnetic field strength for NV-based sensors in biological contexts?
  • RQ3How can laser power be minimized to preserve cell viability while maintaining high sensing sensitivity?
  • RQ4To what extent can NV sensors resolve localized thermal gradients in cellular microdomains?
  • RQ5What technical improvements are required to enable single-action potential detection in neurons?

Key findings

  • NV centers achieve a temperature sensitivity of approximately 4.8 mK/Hz¹ᐟ² in a 1 µm³ sensing volume at 80 mW laser power, exceeding requirements for most biological processes.
  • With laser power reduced to a few mW, temperature sensitivity remains sufficient to resolve biological processes with sub-degree precision.
  • NV-based sensors have successfully detected magnetic fields from magnetotactic bacteria and squid axons, which are significantly stronger than those from human neurons.
  • The estimated cardiac magnetic field on the heart surface is within the current detection capability of optimized NV sensors using pulsed protocols and engineered diamond samples.
  • Detection of single-action potential magnetic fields remains challenging due to weak coupling, but clustered neuronal activity is a feasible near-term target.
  • Localized thermal gradients linked to mitochondrial activity and neurotransmitter release can be reliably monitored using NV-based thermometry.