Skip to main content
QUICK REVIEW

[Paper Review] Laser induced fluorescence for axion dark matter detection: a feasibility study in YLiF$_4$:Er$^{3+}$

C. Braggio, G. Carugno|arXiv (Cornell University)|Jul 19, 2017
Cold Atom Physics and Bose-Einstein CondensatesPhysics and Astronomy10 citations
TL;DR

This paper proposes a novel solid-state detection scheme for QCD axion dark matter using laser-induced fluorescence in YLiF₄:Er³⁺ crystals, where axion-induced transitions between Zeeman-split levels are upconverted to detectable photons via a pump laser. The key finding is that laser-induced heating does not significantly populate the target excited state up to 4 W/cm², and the system resolves Zeeman transitions at 4.2 K, enabling feasibility for axion detection in the 100 μeV range.

ABSTRACT

We present a detection scheme to search for QCD axion dark matter, that is based on a direct interaction between axions and electrons explicitly predicted by DFSZ axion models. The local axion dark matter field shall drive transitions between Zeeman-split atomic levels separated by the axion rest mass energy $m_a c^2$. Axion-related excitations are then detected with an upconversion scheme involving a pump laser that converts the absorbed axion energy ($\sim $ hundreds of $μ$eV) to visible or infrared photons, where single photon detection is an established technique. The proposed scheme involves rare-earth ions doped into solid-state crystalline materials, and the optical transitions take place between energy levels of $4f^N$ electron configuration. Beyond discussing theoretical aspects and requirements to achieve a cosmologically relevant sensitivity, especially in terms of spectroscopic material properties, we experimentally investigate backgrounds due to the pump laser at temperatures in the range $1.9-4.2$ K. Our results rule out excitation of the upper Zeeman component of the ground state by laser-related heating effects, and are of some help in optimizing activated material parameters to suppress the multiphonon-assisted Stokes fluorescence.

Motivation & Objective

  • To develop a direct detection method for QCD axion dark matter in the 100 μeV mass range using axion-electron coupling predicted in DFSZ models.
  • To demonstrate the feasibility of upconverting axion-induced transitions in rare-earth-doped crystals to detectable optical photons using laser-induced fluorescence.
  • To assess and suppress background signals from pump laser-induced heating and multiphonon-assisted Stokes fluorescence in ultracold conditions.
  • To optimize material parameters—dopant concentration, host matrix, and pumping pathway—to minimize background and maximize detection sensitivity.
  • To establish experimental conditions under which axion-induced transitions can be distinguished from thermal and laser-induced noise.

Proposed method

  • The detection scheme relies on axion-induced transitions between Zeeman-split levels in Er³⁺ ions, separated by energy mₐc² ≈ 100 μeV, corresponding to ~24 GHz in a magnetic field.
  • A pump laser is tuned to a transition from the excited ⁴I₁₅/₂ level to a higher 4fⁿ level, enabling upconversion of axion energy to visible/infrared photons detectable by single-photon counters.
  • Laser-induced fluorescence (LIF) measurements are performed at 1.9–4.2 K to probe population of the Zeeman-excited ground state and assess laser-induced heating effects.
  • The system uses YLiF₄:Er³⁺ crystals with Er³⁺ concentrations of 0.01% and 1%, where the low-dopant sample allows resolution of Zeeman transitions due to reduced spectral overlap.
  • Background suppression is targeted by selecting low-phonon-energy host matrices and optimizing the pump laser detuning (E − E₁) to reduce multiphonon-assisted Stokes fluorescence.
  • Thermal population of the target excited state is modeled as the dominant noise source, with signal-to-noise ratio (SNR) ≥ 3 required for detection, setting a lower temperature limit of ~0.2 K.

Experimental results

Research questions

  • RQ1Can axion-induced transitions in Er³⁺:YLiF₄ be upconverted to detectable photons using a pump laser without significant laser-induced heating of the target state?
  • RQ2What is the maximum pump laser intensity that can be applied without thermally populating the Zeeman-excited ground state at ultracold temperatures?
  • RQ3To what extent do multiphonon-assisted Stokes processes contribute to background fluorescence in the 4fⁿ electronic transitions of Er³⁺?
  • RQ4Can Zeeman-split transitions in the ground state of Er³⁺ be resolved in low-concentration YLiF₄:Er³⁺ at 4.2 K using LIF?
  • RQ5What material and experimental parameters (dopant concentration, host matrix, magnetic field, laser wavelength) are optimal for suppressing background and enabling cosmologically relevant sensitivity?

Key findings

  • The pump laser does not significantly populate the Zeeman-excited level of the Er³⁺ ground state up to 4 W/cm² intensity at 1.9–4.2 K, indicating minimal laser-induced heating effects.
  • At 4.2 K and 370 mT magnetic field, the four Zeeman transitions coupling the ⁴I₉/₂ ground and excited states are resolved in the 0.01% Er³⁺-doped YLiF₄ sample, but not in the 1% sample due to spectral broadening.
  • The absorption coefficient for Stokes fluorescence is measured as α_S = 9.2 × 10⁻³ cm⁻¹, consistent with literature, indicating a significant background source that must be suppressed.
  • The thermal excitation rate of the target state is the dominant noise source; to achieve SNR ≥ 3, the detector must be cooled below ~0.2 K for 80 GHz transitions with a 1 ms excited-state lifetime.
  • With a 10 W/cm² pump intensity and τ ≥ 100 μs, upconversion efficiency remains near unity, enabling effective signal conversion.
  • The dark count rate of state-of-the-art single-photon detectors is below the expected axion transition rate in a few-liter active volume, making detection feasible.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.