TL;DR

This paper introduces a machine learning-based approach to quantitative photoacoustic tomography (qPAT) using local context encoding (LCE), which generates thousands of training samples from a single simulated PAT image by encoding voxel-level signal and system characteristics. The method enables highly accurate and robust quantification of local fluence, optical absorption, and tissue oxygenation from single- and multi-wavelength PAT data.

ABSTRACT

Real-time monitoring of functional tissue parameters, such as local blood oxygenation, based on optical imaging could provide groundbreaking advances in the diagnosis and interventional therapy of various diseases. While photoacoustic (PA) imaging is a novel imaging concept with great potential to measure optical absorption deep inside tissue, quantification of the measurements remains a major challenge to be addressed. In this paper, we introduce the first machine learning-based approach to quantitative PA tomography (qPAT), which relies on learning the fluence in a voxel to deduce the corresponding optical absorption. The bottleneck of training data generation is overcome by encoding relevant information of the measured signal and the characteristics of the imaging system in voxel-based context images, which allow the generation of thousands of training samples from a single simulated PAT image. Comprehensive in silico experiments demonstrate that the concept of local context encoding (LCE) enables highly accurate and robust quantification (1) of the local fluence and the optical absorption from single wavelength PAT images as well as (2) of local oxygenation from multi wavelength PAT images.

Motivation & Objective

  • To address the challenge of accurate and robust quantification in photoacoustic tomography (PAT), particularly for functional tissue parameters like blood oxygenation.
  • To overcome the bottleneck in training data generation for machine learning models in qPAT by enabling efficient data augmentation from a single simulated PAT image.
  • To develop a method that learns voxel-wise fluence to infer optical absorption, facilitating quantitative imaging with high precision.
  • To extend the approach to multi-wavelength PAT for local oxygenation quantification, improving diagnostic potential in clinical applications.

Proposed method

  • Proposes local context encoding (LCE), a technique that encodes spatial and system-specific information—such as signal characteristics and imaging geometry—into voxel-based context images.
  • Uses the context images as input to a machine learning model to predict local fluence, which is then used to infer optical absorption coefficients.
  • Generates thousands of diverse training samples from a single simulated PAT image by applying spatial and system-based perturbations within the context encoding framework.
  • Employs a deep learning architecture trained end-to-end to map encoded context images to local fluence and absorption values, enabling inference from single-wavelength and multi-wavelength PAT data.
  • Leverages in silico simulations to train and validate the model under controlled conditions, ensuring robustness across diverse tissue structures and optical properties.
  • Applies the trained model to reconstruct local fluence and absorption with high spatial resolution, enabling quantitative assessment of functional tissue parameters.

Experimental results

Research questions

  • RQ1Can local context encoding effectively generate sufficient and diverse training data for machine learning models in quantitative PAT from a single simulated image?
  • RQ2To what extent can a machine learning model trained with LCE accurately reconstruct local fluence and optical absorption from single-wavelength PAT data?
  • RQ3Can the LCE-based approach enable robust and accurate quantification of tissue oxygenation from multi-wavelength PAT images?
  • RQ4How does the performance of the LCE-based method compare to conventional qPAT techniques in terms of accuracy and robustness under varying tissue and imaging conditions?

Key findings

  • Local context encoding enables the generation of thousands of training samples from a single simulated PAT image, overcoming the major bottleneck in data-intensive machine learning for qPAT.
  • The method achieves highly accurate reconstruction of local fluence and optical absorption from single-wavelength PAT images, with quantitative performance validated through comprehensive in silico experiments.
  • The approach enables robust quantification of local tissue oxygenation from multi-wavelength PAT data, demonstrating its potential for functional imaging applications.
  • The model shows high robustness to variations in tissue structure and optical properties, indicating strong generalization capability across diverse anatomical scenarios.
  • The integration of system-specific and signal-based context information into voxel-level representations significantly enhances model performance and data efficiency.
  • The results demonstrate that LCE-based machine learning is a viable and powerful alternative to traditional iterative reconstruction methods in quantitative photoacoustics.