[Paper Review] M(H) dependence and size distribution of SPIONs measured by atomic magnetometry

Simone Colombo, Victor Lebedev|arXiv (Cornell University)|Nov 27, 2015
Characterization and Applications of Magnetic NanoparticlesEngineering6 citations
TL;DR

This study demonstrates that atomic magnetometry enables precise, quasi-static measurement of the magnetic excitation function M(H) in superparamagnetic iron oxide nanoparticles (SPIONs), allowing accurate determination of iron mass content and particle size distribution. By replacing conventional induction coils with an optically pumped magnetometer (OPM), the method achieves pico-tesla sensitivity, enabling quantitative analysis of SPION suspensions with sub-microgram iron mass detection limits.

ABSTRACT

We demonstrate that the quasistatic recording of the magnetic excitation function M(H) of superparamagnetic iron oxide nanoparticle (SPION) suspensions by an atomic magnetometer allows a precise determination of the sample's iron mass content mFe and the particle size distribution.

Motivation & Objective

  • To develop a high-sensitivity method for quantifying iron mass content and particle size distribution in SPION suspensions.
  • To overcome limitations of conventional induction coil-based detection by using atomic magnetometry for quasi-static M(H) measurements.
  • To enable precise, low-dose SPION characterization suitable for biomedical applications such as targeted drug delivery and MPI.
  • To validate the method's accuracy by comparing fitted parameters with manufacturer and literature values.
  • To monitor SPION aging effects through the detection of bimodal size distributions arising from cluster formation.

Proposed method

  • Employed an optically pumped magnetometer (OPM) operating as an Mx magnetometer to detect pico-tesla-level magnetic induction signals from time-varying magnetization of SPIONs.
  • Used a double-layered, oppositely wound solenoid to generate a harmonic excitation field (Hdrive(t)) with minimal stray fields, reducing interference at the OPM location by a factor of 10^6.
  • Applied a digital lock-in amplifier with a phase-locked loop to measure frequency shifts (δfNP) proportional to the magnetic induction δBNP from SPIONs.
  • Fitted the measured M(H) curves to a theoretical model based on the superparamagnetic Néel relaxation and Langevin function to extract size distribution parameters.
  • Fixed saturation magnetization (MS) to literature values (340 kA/m for Resovist, 418 kA/m for EMG-707) and performed both mono- and bi-modal fits to the mass fraction distribution.
  • Calibrated the system using samples with known iron mass content (4.2 mg for Resovist, 10.2 mg for EMG-707) to determine sensitivity and accuracy.

Experimental results

Research questions

  • RQ1Can atomic magnetometry provide a viable alternative to induction coils for measuring the quasi-static M(H) response of SPION suspensions?
  • RQ2To what extent can atomic magnetometry resolve the iron mass content and particle size distribution in SPION samples with high precision?
  • RQ3How does the choice of mono- vs. bi-modal size distribution models affect the fit quality and parameter extraction?
  • RQ4What is the detection sensitivity of the OPM-based system for low-iron-content SPION samples?
  • RQ5Can the method detect changes in SPION size distribution due to aging and cluster formation?

Key findings

  • The OPM-based system achieved a detection sensitivity of m_tot_Fe ≲ 7 µg for iron mass content, as inferred from low-concentration samples.
  • Bi-modal size distribution fits yielded the best figure of merit (FOM = 0.43 for Resovist, 0.98 for EMG-707), indicating superior agreement with experimental M(H) curves compared to mono-modal fits.
  • For Resovist, the extracted parameters (MS = 340 kA/m, mode at 4.3/2.4 nm) matched literature values and previous studies by Eberbeck et al. [15].
  • For EMG-707, the smaller size mode (5.3/2.1 nm) from the bi-modal fit agreed with the histogram reported in Ref. [16].
  • The method successfully detected bimodal size distributions in aged SPION samples, indicating cluster formation over time.
  • The iron mass content inferred from fitting showed excellent agreement with manufacturer specifications (slope = 1 in m_tot_Fe vs. m_spec_Fe plot), confirming calibration accuracy.