Skip to main content
QUICK REVIEW

[Paper Review] MAUS: A Dataset for Mental Workload Assessmenton N-back Task Using Wearable Sensor

Win-Ken Beh, Yi‐Hsuan Wu|arXiv (Cornell University)|Nov 3, 2021
Human-Automation Interaction and SafetyPsychology32 references9 citations
TL;DR

This paper introduces MAUS, an open-access dataset for mental workload (MW) assessment using wearable sensors during N-back tasks. It includes synchronized ECG, fingertip PPG, wristband PPG, and GSR from 22 subjects, with NASA-TLX ratings for validation. The baseline system achieves 71.6% accuracy on ECG, 66.7% on fingertip PPG, and 59.9% on wristband PPG using SVM classification, offering a reproducible benchmark for MW research.

ABSTRACT

This paper describes an open-access database focusing on the study of mental workload (MW) assessment system for wearable devices. A wristband photoplethysmogram (PPG) was provided as a representative of wearable devices. In addition, a clinical device that can record Electrocardiography (ECG) , galvanic skin response (GSR) and, fingertip PPG was included in the database as a reference. The MW was induced by performing the N-back task with 22 subjects. The participants were asked to answer the Pittsburgh Sleep Quality Index (PSQI) questionnaire at the beginning of the experiment and the NASA Task Load Index (NASA-TLX) questionnaire after each N-back task. The result of data analysis show the potential uses of the recorded modalities and the feasibility of the MW elicitation protocol. Finally the MAUS dataset is now available for academic use (The MAUS dataset is available at IEEE Dataport: https://ieee-dataport.org/open-access/maus-dataset-mental-workload-assessment-n-back-task-using-wearable-sensor). Besides, we also presents a reproducible baseline system as a preliminary benchmark (The code of the baseline system on MAUS dataset is available on Github: https://github.com/rickwu11/MAUS\_dataset\_baseline\_system), which testing accuracy are 71.6 %, 66.7 %, and 59.9 % in ECG, fingertip PPG, wristband PPG, respectively.

Motivation & Objective

  • To develop an open-access, reproducible dataset for mental workload (MW) assessment using wearable physiological sensors.
  • To enable fair comparison of MW assessment methods across different sensor modalities, especially wristband vs. fingertip PPG.
  • To provide synchronized recordings of ECG, GSR, fingertip PPG, and wristband PPG under controlled MW conditions.
  • To support the development and benchmarking of algorithms for continuous MW monitoring using wearable devices.
  • To offer a reproducible baseline system for future method validation and performance comparison.

Proposed method

  • The study employed the N-back task to induce varying levels of mental workload, with N=1, 2, and 3 used as increasing difficulty levels.
  • Physiological signals were collected using a clinical device (ECG, GSR, fingertip PPG) and a wearable PPG wristband.
  • Participants completed the Pittsburgh Sleep Quality Index (PSQI) before and the NASA Task Load Index (NASA-TLX) after each N-back session for subjective MW assessment.
  • A support vector machine (SVM) classifier was trained on time-domain and frequency-domain features extracted from ECG, PPG, and GSR signals.
  • Two cross-validation strategies were used: leave-one-subject-out (LOSO) and mixed-subject 5-fold cross-validation to evaluate generalization and robustness.
  • Feature engineering focused on heart rate variability (HRV) from ECG and PPG, along with GSR amplitude and skin conductance response features.

Experimental results

Research questions

  • RQ1Can wearable PPG signals from wristbands reliably assess mental workload under controlled N-back task conditions?
  • RQ2How does the performance of wristband PPG compare to fingertip PPG and ECG in mental workload classification?
  • RQ3To what extent do subjective NASA-TLX ratings correlate with physiological signals and N-back task difficulty?
  • RQ4Can a reproducible baseline system be established to enable fair comparison across future MW assessment algorithms?
  • RQ5What is the feasibility of multimodal fusion using ECG, PPG, and GSR for improved mental workload detection?

Key findings

  • The ECG modality achieved the highest classification accuracy of 71.6% in the leave-one-subject-out (LOSO) validation, with an F1-score of 71.9%.
  • Fingertip PPG achieved 66.7% accuracy and 65.0% F1-score in LOSO, showing moderate performance and approaching ECG results.
  • Wristband PPG showed the lowest performance with 59.9% accuracy and 58.0% F1-score in LOSO, indicating significant signal quality challenges.
  • In mixed-subject 5-fold cross-validation, ECG maintained strong performance (71.7% accuracy), while wristband PPG improved to 64.8% accuracy.
  • ANOVA analysis revealed consistent HRV trends between ECG and fingertip PPG, but wristband PPG showed significant differences, suggesting distinct signal characteristics.
  • The large performance gap between ECG and wristband PPG highlights the need for signal enhancement techniques in wearable PPG for MW assessment.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.