[Paper Review] Measurements of the ionization efficiency of protons in methane
This study presents the first direct measurement of the ionization quenching factor (IQF) for protons in 100 mbar of methane at kinetic energies between 2 keV and 13 keV, using the Comimac facility to produce calibrated ion beams and a spherical proportional counter (SPC) for energy detection. The results show a 33% deviation below SRIM simulations at 2 keV, with a best-fit IQF model of IQF(EK) = EK^0.70 / (1.32 + EK^0.70), challenging the reliability of standard simulation tools for low-energy nuclear recoils in dark matter searches.
The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears "quenched" compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below $50~\mathrm{keV}$), IQF measurements deviate significantly from common models used for theoretical predictions and simulations. We report measurements of the IQF for proton, an appropriate target for searches of Dark Matter candidates with a mass of approximately 1 GeV, with kinetic energies in between $2~\mathrm{keV}$ and $13~\mathrm{keV}$ in $100~\mathrm{mbar}$ of methane. We used the Comimac facility in order to produce the motion of nuclei and electrons of controlled kinetic energy in the active volume, and a NEWS-G SPC to measure the deposited energy. The Comimac electrons are used as reference to calibrate the detector with 7 energy points. A detailed study of systematic effects led to the final results well fitted by $\mathrm{IQF}~(E_K)= E_K^\alpha~/~(\beta + E_K^\alpha)$ with $\alpha=0.70\pm0.08$ and $\beta = 1.32\pm0.17$. In agreement with some previous works in other gas mixtures, we measured less ionization energy than predicted from SRIM simulations, the difference reaching $33\%$ at $2~\mathrm{keV}$
Motivation & Objective
- To measure the ionization quenching factor (IQF) for protons in methane at low kinetic energies (2–13 keV), where theoretical models show significant deviations.
- To validate a direct calibration method using Comimac-generated ions and electrons in the same detector conditions, avoiding reliance on neutron-based recoil calibration.
- To quantify systematic uncertainties in the SPC response and detector gain to ensure accurate IQF determination.
- To provide a benchmark dataset for improving simulations used in direct dark matter searches, particularly for light WIMPs.
Proposed method
- Utilized the Comimac facility to produce mono-energetic protons and electrons with precisely controlled kinetic energies between 700 eV and 50 keV.
- Employed a spherical proportional counter (SPC) with ACHINOS sensor to detect ionization energy with high gain and single-electron sensitivity.
- Performed direct calibration by comparing ion and electron signals in identical conditions, using electron data to define the calibration function fcalib(EADU) that maps measured signal (ADU) to equivalent electron kinetic energy.
- Applied a parametrization IQF(EK) = EK^α / (β + EK^α) to fit the IQF data, with α and β determined via least-squares fitting to experimental points.
- Conducted a detailed analysis of systematic effects, including gain non-linearity and energy resolution, to ensure robust uncertainty quantification.
- Used 1230 V and 1270 V high-voltage settings to test consistency and confirm that results were independent of gain effects down to 9 keV.
Experimental results
Research questions
- RQ1How does the ionization quenching factor (IQF) for protons in methane vary with kinetic energy in the 2–13 keV range, where standard models fail?
- RQ2To what extent do SRIM simulations and Lindhard theory predictions deviate from direct experimental measurements of IQF at low energies?
- RQ3Can the Comimac facility provide a reliable, direct calibration method for IQF measurements without requiring neutron sources or coincidence detection?
- RQ4What is the impact of detector gain non-linearity on IQF determination, and how can it be corrected using co-located electron and ion signals?
- RQ5Does the IQF in methane depend on gas pressure, and how does this affect the validity of simulations assuming constant stopping power?
Key findings
- The measured IQF for protons in 100 mbar of methane deviates significantly from SRIM simulations, with a 33% lower ionization yield at 2 keV kinetic energy.
- The best-fit parametrization of the IQF is IQF(EK) = EK^0.70 / (1.32 + EK^0.70), with α = 0.70 ± 0.08 and β = 1.32 ± 0.17, providing a precise empirical model for low-energy proton recoils.
- Measurements at 1230 V and 1270 V high voltage show consistent IQF values down to 9 keV, indicating that the observed non-linearity in detector response does not bias the results.
- A 4% uncertainty in Comimac's kinetic energy is the dominant source of error, with systematic uncertainties fully accounted for in the final error bars.
- The results confirm that SRIM simulations overestimate ionization yield in the keV range, suggesting limitations in its applicability for low-energy nuclear recoils in gaseous detectors.
- This work establishes the first direct measurement of IQF for protons in methane, a key medium for low-mass WIMP and CEνNS searches, providing a critical calibration benchmark.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.