This paper evaluates the commercial viability of diamond nitrogen-vacancy (NV⁻) magnetometers for medical applications, particularly magnetocardiography (MCG) and magnetoencephalography (MEG). It proposes that NV⁻ centers in diamond enable room-temperature, robust, and potentially low-cost magnetic sensing with sensitivity approaching SQUID and alkali-vapor standards, offering advantages in portability, ruggedness, and reduced need for cryogenic cooling or magnetic shielding.

ABSTRACT

The sensing of magnetic fields has important applications in medicine, particularly to the sensing of signals in the heart and brain. The fields associated with biomagnetism are exceptionally weak, being many orders of magnitude smaller than the Earth's magnetic field. To measure them requires that we use the most sensitive detection techniques, however, to be commercially viable this must be done at an affordable cost. The current state of the art uses costly SQUID magnetometers, although they will likely be superseded by less costly, but otherwise limited, alkali vapour magnetometers. Here, we discuss the application of diamond magnetometers to medical applications. Diamond magnetometers are robust, solid state devices that work in a broad range of environments, with the potential for sensitivity comparable to the leading technologies.

Motivation & Objective

  • To assess whether diamond NV⁻ magnetometers can achieve the sensitivity required for clinical biomagnetic sensing, such as MCG and MEG.
  • To evaluate the commercial viability of diamond-based magnetometers compared to existing SQUID and alkali-vapor magnetometers.
  • To identify technical and economic advantages of NV⁻ magnetometers, including room-temperature operation, reduced shielding needs, and lower manufacturing costs.
  • To explore how improvements in diamond material quality, sensor design, and optical detection can close the sensitivity gap with state-of-the-art sensors.
  • To determine the technology readiness level (TRL) of diamond magnetometers for medical applications and identify remaining development hurdles.

Proposed method

  • Leverages the nitrogen-vacancy (NV⁻) center in diamond as a quantum sensor, utilizing its electron spin state for magnetic field detection via optical detection of magnetic resonance (ODMR).
  • Uses optical pumping and microwave excitation to polarize the NV⁻ spin state, with magnetic field-dependent splitting of spin sublevels measured via changes in photoluminescence intensity.
  • Employs room-temperature operation with broadband optical excitation via LEDs, reducing cost compared to laser-based systems used in alkali-vapor sensors.
  • Proposes ellipsoidal reflectors and fiber-optic coupling to maximize collection of NV⁻ photoluminescence, improving signal-to-noise ratio.
  • Analyzes sensitivity scaling with measurement volume and coherence time, noting that long spin coherence times in diamond (especially with ¹²C enrichment) enhance performance.
  • Compares performance to SQUID and alkali-vapor magnetometers, particularly in the SERF regime, where sub-femtotesla sensitivity is achievable but requires ultra-low-field environments.

Experimental results

Research questions

  • RQ1Can diamond NV⁻ magnetometers achieve the required sensitivity of ~50 fT/Hz¹ᐟ² for clinical MCG and MEG applications?
  • RQ2What are the key technical and economic advantages of NV⁻ magnetometers over SQUID and alkali-vapor magnetometers in medical settings?
  • RQ3To what extent can LED-based optical excitation and improved light collection reduce system cost and complexity compared to laser-based systems?
  • RQ4How does the performance of NV⁻ magnetometers scale with material quality, such as ¹²C enrichment and defect engineering?
  • RQ5What is the current technology readiness level (TRL) of NV⁻ magnetometers for medical use, and what development milestones remain?

Key findings

  • Diamond NV⁻ magnetometers currently operate at a sensitivity of ~100 fT/Hz¹ᐟ², which is several orders of magnitude below the state-of-the-art SQUID and alkali-vapor sensors but shows potential for improvement.
  • The use of LEDs instead of stabilized lasers for optical excitation could reduce system cost significantly, as broadband excitation is possible due to phonon coupling in the diamond lattice.
  • Ellipsoidal reflectors and fiber-optic coupling could enable near-100% collection efficiency of NV⁻ photoluminescence, addressing a key signal collection challenge.
  • NV⁻ centers in diamond exhibit exceptionally long spin coherence times at room temperature—especially in ¹²C-enriched, high-purity diamond—making them promising for high-sensitivity detection.
  • The technology is at TRL 7 for the sensor itself, but at TRL 4–5 for full MCG systems, indicating that while the sensor is functional, system integration and sensitivity optimization remain challenges.
  • Despite lower current sensitivity, NV⁻ magnetometers offer major advantages in ruggedness, portability, and reduced need for cryogenic cooling or magnetic shielding, which could enable widespread clinical deployment if sensitivity is improved.