[Paper Review] Mitigating the measurement overhead of ADAPT-VQE with optimised informationally complete generalised measurements
This paper proposes AIM-ADAPT-VQE, a method that eliminates the measurement overhead in ADAPT-VQE by reusing informationally complete (IC) measurement data from energy estimation to classically compute all necessary operator gradients. The approach achieves chemical precision with minimal additional measurements, enabling near-ideal CNOT counts and robust convergence even with limited data, thus enabling efficient, shallow-circuit quantum simulations for molecular systems.
ADAPT-VQE stands out as a robust algorithm for constructing compact ansätze for molecular simulation. It enables to significantly reduce the circuit depth with respect to other methods, such as UCCSD, while achieving higher accuracy and not suffering from so-called barren plateaus that hinder the variational optimisation of many hardware-efficient ansätze. In its standard implementation, however, it introduces a considerable measurement overhead in the form of gradient evaluations trough estimations of many commutator operators. In this work, we mitigate this measurement overhead by exploiting a recently introduced method for energy evaluation relying on Adaptive Informationally complete generalised Measurements (AIM). Besides offering an efficient way to measure the energy itself, Informationally Complete (IC) measurement data can be reused to estimate all the commutators of the operators in the operator pool of ADAPT-VQE, using only classically efficient post-processing. We present the AIM-ADAPT-VQE scheme in detail, and investigate its performance with several H4 Hamiltonians and operator pools. Our numerical simulations indicate that the measurement data obtained to evaluate the energy can be reused to implement ADAPT-VQE with no additional measurement overhead for the systems considered here. In addition, we show that, if the energy is measured within chemical precision, the CNOT count in the resulting circuits is close to the ideal one. With scarce measurement data, AIM-ADAPT-VQE still converges to the ground state with high probability, albeit with an increased circuit depth in some cases.
Motivation & Objective
- To address the high measurement overhead in ADAPT-VQE caused by repeated gradient evaluations of operator pool elements.
- To explore whether informationally complete (IC) measurements used for energy estimation can be reused to compute all required gradients without additional quantum measurements.
- To evaluate the performance of the proposed AIM-ADAPT-VQE scheme on molecular systems like H₄ and N₂ with varying measurement precision and operator pools.
- To determine if the method maintains low circuit depth and high accuracy even with reduced measurement data, enabling use on noisy or slow hardware platforms.
Proposed method
- Leverages Adaptive Informationally Complete Positive Operator-Valued Measures (AIM) to measure the energy of the ansatz state with a number of shots well below full state tomography.
- Reuses the same IC measurement data collected during energy estimation to classically compute gradients of all operators in the pool via linear combinations of expectation values.
- Employs classical post-processing to estimate all required gradients using only the IC data, avoiding additional quantum circuit executions.
- Uses a hybrid quantum-classical optimization loop where the quantum processor prepares the state and measures the energy, and the classical processor computes gradients from the IC data.
- Applies the method to H₄ and N₂ molecules using different fermion-to-qubit mappings and operator pools to assess robustness and scalability.
- Evaluates convergence and CNOT count performance under varying measurement precision thresholds, including chemical precision and relative error targets.
Experimental results
Research questions
- RQ1Can IC measurement data collected during energy estimation in ADAPT-VQE be reused to compute all operator gradients with no additional measurement cost?
- RQ2What is the minimum number of measurement shots required to achieve chemical precision in energy and gradient estimation using AIM-ADAPT-VQE?
- RQ3How does the measurement cost of AIM-ADAPT-VQE scale with system size compared to full state tomography?
- RQ4Does AIM-ADAPT-VQE maintain low circuit depth (CNOT count) when using approximate measurements, and can it outperform exact simulations in this metric?
- RQ5How robust is the algorithm to reduced measurement precision, and can it still converge to the ground state with high probability?
Key findings
- For both H₄ and N₂, AIM-ADAPT-VQE achieved chemical precision in energy estimation with measurement counts well below the full tomographic scale of 4^N.
- The same IC measurement data used for energy estimation enabled full gradient computation for all operators in the pool with no additional quantum measurements, effectively eliminating the measurement overhead.
- When energy was measured within 3 mHa precision, the resulting circuits had CNOT counts close to the ideal (statevector simulation) values, and in some cases even lower.
- With reduced measurement precision, such as T_τ = 20% relative error, the algorithm still converged to the ground state with high probability, though with increased circuit depth.
- The method showed robustness across different operator pools and fermion-to-qubit mappings, with some configurations being more resilient than others.
- The classical post-processing cost scales linearly with the size of the operator pool, enabling exploration of larger pools without increasing quantum measurement cost.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.