[Paper Review] MM-NeuroOnco: A Multimodal Benchmark and Instruction Dataset for MRI-Based Brain Tumor Diagnosis
MM-NeuroOnco builds a large multimodal MRI dataset with semantically enriched instructions and a rejection-aware evaluation benchmark to study diagnostic reasoning in brain tumor MRI understanding. NeuroOnco-GPT shows improved diagnostic reasoning after fine-tuning on this data.
Accurate brain tumor diagnosis requires models to not only detect lesions but also generate clinically interpretable reasoning grounded in imaging manifestations, yet existing public datasets remain limited in annotation richness and diagnostic semantics. To bridge this gap, we introduce MM-NeuroOnco, a large-scale multimodal benchmark and instruction-tuning dataset for brain tumor MRI understanding, consisting of 24,726 MRI slices from 20 data sources paired with approximately 200,000 semantically enriched multimodal instructions spanning diverse tumor subtypes and imaging modalities. To mitigate the scarcity and high cost of diagnostic semantic annotations, we develop a multi-model collaborative pipeline for automated medical information completion and quality control, enabling the generation of diagnosis-related semantics beyond mask-only annotations. Building upon this dataset, we further construct MM-NeuroOnco-Bench, a manually annotated evaluation benchmark with a rejection-aware setting to reduce biases inherent in closed-ended question formats. Evaluation across ten representative models shows that even the strongest baseline, Gemini 3 Flash, achieves only 41.88% accuracy on diagnosis-related questions, highlighting the substantial challenges of multimodal brain tumor diagnostic understanding. Leveraging MM-NeuroOnco, we further propose NeuroOnco-GPT, which achieves a 27% absolute accuracy improvement on diagnostic questions following fine-tuning. This result demonstrates the effectiveness of our dataset and benchmark in advancing clinically grounded multimodal diagnostic reasoning. Code and dataset are publicly available at: https://github.com/gfnnnb/MM-NeuroOnco
Motivation & Objective
- Bridge the gap between lesion detection and clinically grounded diagnostic reasoning in brain MRI analysis.
- Create a large-scale, multimodal instruction-tuning dataset with rich semantic attributes and chain-of-thought prompts.
- Develop automated semantic completion and quality-control pipelines to generate diagnostics-related semantics at scale.
- Provide an evaluation benchmark (MM-NeuroOnco-Bench) with a rejection-aware setting to reduce bias in closed-ended questions.
- Demonstrate the effectiveness of fine-tuning with NeuroOnco-GPT and assess the limits of current LVLMs in neuro-oncology tasks.
Proposed method
- Assemble 24,726 MRI slices from 20 sources across eight tumor subtypes and healthy controls.
- Extract semantic attributes (morphology, localization, spatial spread) from pixel masks and map them to textual prompts.
- Use a Multi-Model Collaborative Pipeline (Dual-Path Extraction, Consensus Fusion, Visual Verification) to produce silver-standard radiological attributes and reduce hallucinations.
- Construct instruction data by pairing golden labels with silver attributes to produce structured VQA prompts and chain-of-thought reasoning traces.
- Evaluate with MM-NeuroOnco-Bench, a manually annotated subset with a rejection-aware 5-option closed-ended setup and open-ended questions.
- Fine-tune a domain-adapted LVLM (NeuroOnco-GPT) using supervised fine-tuning and assess performance under rejection-aware evaluation.
Experimental results
Research questions
- RQ1Can multimodal MRI data, enriched with explicit semantic attributes and CoT reasoning, improve diagnostic understanding beyond lesion detection?
- RQ2How does a rejection-aware evaluation affect measured capabilities of medical LVLMs in brain tumor diagnosis?
- RQ3What is the gap between general-purpose LVLMs, medical-specialist LVLMs, and a domain-adapted NeuroOnco-GPT on MRI-based diagnosis tasks?
- RQ4Does explicit CoT supervision plus structured attributes improve open-ended and closed-ended diagnostic questions?
- RQ5How effective is automated semantic completion in producing reliable diagnostic semantics at scale?
Key findings
- Strong baseline models achieve limited accuracy on diagnosis-related questions (e.g., Gemini 3 Flash at 41.88% overall on diagnosis-related questions).
- NeuroOnco-GPT improves diagnostic question accuracy by about 27 percentage points after fine-tuning.
- Rejection-aware evaluation reduces forced-choice bias and lowers average accuracy of large models by about 7.82% beyond a standard five-option setup.
- CoT supervision yields an additional ~11.4% gain in performance under low-resource fine-tuning.
- Domain-adapted medical LVLMs do not consistently outperform general-purpose LVLMs on MM-NeuroOnco-Bench, highlighting the need for structured clinical reasoning beyond domain exposure.
- MM-NeuroOnco-Bench ground-truths are held to human annotation standards, with a diverse set of over 2,000 closed-ended and 1,000 open-ended questions.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.