[Paper Review] Multi-scale Transactive Control In Interconnected Bulk Power Systems Under High Renewable Energy Supply and High Demand Response Scenarios
This paper proposes a multi-scale transactive control framework for interconnected bulk power systems under high renewable energy and demand response penetration, integrating hierarchical control across area, feeder, and device levels using real-time market signals and autonomous responses. The key contribution is a co-optimized, dynamic control architecture that enables coordinated energy and ancillary services dispatch while maintaining system stability under high variability and contingency conditions.
This thesis presents the design, analysis, and validation of a hierarchical transactive control system that engages demand response resources to enhance the integration of renewable electricity generation resources. This control system joins energy, capacity and regulation markets together in a unified homeostatic and economically efficient electricity operation that increases total surplus while improving reliability and decreasing carbon emissions from fossil-based generation resources. The work encompasses: (1) the derivation of a short-term demand response model suitable for transactive control systems and its validation with field demonstration data; (2) an aggregate load model that enables effective control of large populations of thermal loads using a new type of thermostat (discrete time with zero deadband); (3) a methodology for optimally controlling response to frequency deviations while tracking schedule area exports in areas that have high penetration of both intermittent renewable resources and fast-acting demand response; and (4) the development of a system-wide (continental interconnection) scale strategy for optimal power trajectory and resource dispatch based on a shift from primarily energy cost-based approach to a primarily ramping cost-based one. The results show that multi-layer transactive control systems can be constructed, will enhance renewable resource utilization, and will operate in a coordinated manner with bulk power systems that include both regions with and without organized power markets. Estimates of Western Electric Coordionating Council (WECC) system cost savings under target renewable energy generation levels resulting from the proposed system exceed US$150B annually by the year 2024, when compared to the existing control system.
Motivation & Objective
- To address the challenges of integrating high levels of renewable energy and demand response in interconnected bulk power systems while maintaining reliability and economic efficiency.
- To develop a hierarchical control architecture that coordinates energy and ancillary services across area, feeder, and device levels in real time.
- To ensure system stability during normal and off-normal conditions by enabling autonomous, fast-acting responses from distributed resources.
- To co-optimize real-time energy and ancillary service markets at multiple time scales, allowing smart grid assets to participate in multiple revenue streams.
- To maintain frequency and voltage stability under high variability by dynamically adjusting control weights based on system conditions.
Proposed method
- Employs a two-stage market-based approach: day-ahead unit commitment and real-time economic dispatch, with real-time adjustments every 5–180 minutes.
- Uses area control to balance generation and load across balancing authorities, relying on tie-line power flow references derived from market-clearing outcomes.
- Implements feeder-level control to reconcile area-level power references with retail market signals, prioritizing system stability during contingencies.
- Deploys autonomous device-level controllers that respond to local voltage and frequency signals, with suppression of local control during system stress to prevent oscillations.
- Integrates co-optimization of energy and ancillary services (e.g., frequency regulation, spinning reserve) at the real-time market level using dynamic weighting functions.
- Applies the swing equation and system frequency dynamics ($df/dt = M\Delta P + D\Delta f$) to model system inertia and frequency response under power imbalance.
Experimental results
Research questions
- RQ1How can transactive control be structured across multiple scales (area, feeder, device) to manage high renewable and demand response integration?
- RQ2What control architecture ensures system stability during normal and contingency conditions while maintaining economic efficiency?
- RQ3How can real-time energy and ancillary services markets be co-optimized to allow multi-revenue participation by smart grid assets?
- RQ4What mechanisms enable autonomous, fast-acting responses from distributed resources without compromising system-wide stability?
- RQ5How can feeder-level control reconcile conflicting power references from area and retail markets under varying system conditions?
Key findings
- The multi-scale transactive control framework successfully coordinates energy and ancillary services across area, feeder, and device levels using real-time market signals and autonomous responses.
- During normal operations, the system prioritizes economic dispatch by giving greater weight to retail market power references, while during contingencies, area control signals are prioritized to ensure stability.
- The framework enables smart grid assets to participate in multiple revenue streams—such as energy and frequency regulation—by co-optimizing market contracts at the 5-minute real-time cycle.
- Feeder controllers effectively manage local constraints such as congestion and distributed renewable variability by dynamically adjusting set-points and suppressing local control signals when necessary.
- The system maintains frequency and voltage stability through coordinated, autonomous responses from loads and distributed resources, even under communication loss or contingency conditions.
- The use of dynamic weighting functions in the control system allows a shift from purely economic objectives to system stability priorities during stressed conditions, ensuring NERC reliability compliance.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.