Skip to main content
QUICK REVIEW

[Paper Review] Neutrino mass calorimetric searches in the MARE experiment

A. Nucciotti|arXiv (Cornell University)|Dec 10, 2010
Neutrino Physics ResearchPhysics and Astronomy1 references7 citations
TL;DR

The MARE experiment proposes a calorimetric approach using low-temperature microcalorimeters to directly measure the electron neutrino mass with sub-eV sensitivity, primarily using 187Re and 163Ho isotopes. It achieves this by embedding the beta-decaying isotope directly in the detector to measure all decay energy except that carried by the neutrino, minimizing systematic uncertainties and enabling a projected statistical sensitivity of 0.1 eV with optimized detector arrays and pile-up mitigation.

ABSTRACT

The international project ``Microcalorimeter Arrays for a Rhenium Experiment'' (MARE) aims at the direct and calorimetric measurement of the electron neutrino mass with sub-electronvolt sensitivity. Calorimetric neutrino mass experiments measure all the energy released in a beta decay except for the energy carried away by the neutrino, therefore removing the most severe systematic uncertainties which have plagued the traditional and, so far, more sensitive spectrometers. Calorimetric measurements are best realized exploiting the thermal detection technique. This approach uses thermal microcalorimeters whose absorbers contain a low transition energy Q beta decaying isotope. To date the two best options are 187Re and 163Ho. While the first beta decays, the latter decays via electron capture, but both have a Q value around 2.5 keV. The potential of using 187Re for a calorimetric neutrino mass experiment has been already demonstrated. On the contrary, no calorimetric spectrum of 163Ho has been so far measured with the precision required to set a useful limit on the neutrino mass. In this talk we present the status and the perspectives of the MARE project activities for the active isotope selection and the single channel development. We also discuss the neutrino mass statistical sensitivity achievable with both isotopes.

Motivation & Objective

  • To develop a direct, calorimetric method for measuring the electron neutrino mass with minimal systematic uncertainties compared to traditional spectrometers.
  • To evaluate and compare the feasibility of using 187Re and 163Ho as beta-decaying isotopes in thermal microcalorimeters for neutrino mass sensitivity.
  • To achieve sub-electronvolt statistical sensitivity by optimizing detector design, energy resolution, and pile-up mitigation in large arrays.
  • To determine the optimal isotope and detector technology (e.g., TES, MMC, MKID) for the final large-scale MARE experiment.
  • To validate the 163Ho transition energy and atomic parameters critical for its use in future neutrino mass measurements.

Proposed method

  • Embedding 187Re or 163Ho isotopes directly into thermal microcalorimeter absorbers to measure all decay energy except that carried by the neutrino.
  • Using low-temperature detectors such as Transition Edge Sensors (TES), Metallic Magnetic Calorimeters (MMC), or Kinetic Inductance Detectors (MKID) for high energy resolution.
  • Employing a statistical model to estimate neutrino mass sensitivity, accounting for activity, background, pile-up, and energy/time resolution.
  • Simulating the pile-up spectrum for 163Ho to assess its impact on end-point sensitivity and spectral distortion.
  • Designing multiplexed readout schemes to scale up detector arrays while maintaining energy and time resolution.
  • Conducting MARE-1 phase experiments to measure the 163Ho spectrum precisely and validate QEC value and atomic parameters.

Experimental results

Research questions

  • RQ1Can 163Ho be used effectively in a calorimetric neutrino mass experiment, given its complex pile-up spectrum and unknown QEC value?
  • RQ2What is the statistical sensitivity achievable with 187Re and 163Ho using optimized microcalorimeter arrays?
  • RQ3How do pile-up effects and detector resolution limit the sensitivity in low-Q beta decay calorimetry?
  • RQ4Which detector technology—TES, MMC, or MKID—offers the best performance for the final MARE experiment?
  • RQ5What is the required detector count and exposure to achieve a 0.1 eV statistical sensitivity for the neutrino mass?

Key findings

  • The MARE project projects a statistical sensitivity of 0.1 eV for the electron neutrino mass using optimized 163Ho-based microcalorimeter arrays.
  • A 0.2 eV sensitivity could be achieved with approximately 1.5×10^4 detectors, each with 100 decay/s activity, over one year of operation.
  • The total number of 163Ho nuclei required for a 0.2 eV sensitivity is about 2×10^17.
  • For 187Re, a sensitivity better than 4 eV at 90% CL is achievable with 288 pixels and 10^10 decays over three years.
  • The 163Ho option is viable only if the QEC value is confirmed to be around 2.2 keV and atomic parameters are favorable.
  • Pile-up effects create a spectral peak near 2.5 keV in 163Ho, which can degrade sensitivity unless properly modeled and mitigated.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.