Skip to main content
QUICK REVIEW

[Paper Review] New Limit on the Permanent Electric Dipole Moment of $^{129}$Xe using $^{3}$He Comagnetometry and SQUID Detection

Natasha Sachdeva, I. Fan|arXiv (Cornell University)|Sep 26, 2019
Atomic and Subatomic Physics ResearchPhysics and Astronomy5 citations
TL;DR

This paper presents a new measurement of the permanent electric dipole moment (EDM) of $^{129}$Xe using $^3$He comagnetometry and SQUID detection in a magnetically shielded environment. The experiment achieves a sensitivity of $|d_A(^{129}\text{Xe})| < 1.4 \times 10^{-27}~e\text{cm}$ at 95% confidence level, representing a fivefold improvement over the previous limit, and provides tighter constraints on beyond-Standard Model CP-violating interactions.

ABSTRACT

We report results of a new technique to measure the electric dipole moment of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pumping, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement campaign in 2017 and a 2.5 week campaign in 2018, combined with detailed study of systematic effects, is $d_A(^{129}\mathrm{Xe}) = (1.4 \pm 6.6_\mathrm{stat} \pm 2.0_\mathrm{syst}) imes10^{-28}~e\,\mathrm{cm}$. This corresponds to an upper limit of $|d_A(^{129}\mathrm{Xe})| &lt; 1.4 imes 10^{-27} ~e\,\mathrm{cm}~(95\%~\mathrm{CL})$, a factor of five more sensitive than the limit set in 2001.

Motivation & Objective

  • To improve the experimental sensitivity to the permanent electric dipole moment (EDM) of $^{129}$Xe, a key probe for new physics beyond the Standard Model.
  • To reduce systematic errors in EDM measurements using $^3$He comagnetometry and SQUID-based detection in a magnetically shielded environment.
  • To test theoretical models of CP violation, including QCD axion contributions and nucleon-nucleon CP-violating interactions, by setting tighter constraints on low-energy CP-violating parameters.
  • To validate and refine the methodology of SQUID detection in combination with spin-exchange optical pumping and comagnetometer techniques for future high-precision EDM experiments.

Proposed method

  • Both $^{129}$Xe and $^3$He were polarized using spin-exchange optical pumping (SEOP) and transferred to a measurement cell within a magnetically shielded room (BMSR-2).
  • Free precession of the nuclear spins was detected using SQUID magnetometers in the presence of applied electric and magnetic fields.
  • The EDM was extracted from the frequency shift of the Larmor precession as a function of the applied electric field, using the Hamiltonian $H = - (\mu \vec{F} \cdot \vec{B} + d \vec{F} \cdot \vec{E}) / F$, which induces a shift $\omega_d = \pm d |E| / (\hbar F)$.
  • Systematic effects such as $\vec{E} \times \vec{v}$ geometric phase, field gradients, and $|\vec{E}|^2$ shifts were carefully modeled and constrained using multiple runs with varying electric field configurations, cell pressures, and magnetic field orientations.
  • Comagnetometer drift was corrected using independent analyses and improved polarization protocols, including optimized $^{129}$Xe/$^3$He polarization ratios and $\pi/2$ flip timing.
  • Statistical and systematic uncertainties were combined using a weighted average, with the final result derived from two measurement campaigns in 2017 and 2018.

Experimental results

Research questions

  • RQ1What is the current best experimental limit on the permanent electric dipole moment of $^{129}$Xe using SQUID-based detection and $^3$He comagnetometry?
  • RQ2How do systematic effects such as $\vec{E} \times \vec{v}$ geometric phase and $|\vec{E}|^2$ shifts impact EDM measurements in noble gas systems?
  • RQ3To what extent can the sensitivity of $^{129}$Xe EDM measurements be improved through optimized polarization, SQUID noise reduction, and extended measurement time?
  • RQ4How do the new results constrain low-energy CP-violating parameters such as $\bar{g}_{\pi}^{0,1}$, $\bar{\theta}$, and the QCD axion coupling $C_T$?
  • RQ5Can $^{129}$Xe serve as a viable comagnetometer in future neutron EDM experiments, and how does its sensitivity compare to other systems?

Key findings

  • The combined result from 2017 and 2018 campaigns yields $d_A(^{129}\text{Xe}) = (1.4 \pm 6.6_{\text{stat}} \pm 2.0_{\text{syst}}) \times 10^{-28}~e\text{cm}$, corresponding to an upper limit of $|d_A(^{129}\text{Xe})| < 1.4 \times 10^{-27}~e\text{cm}$ at 95% confidence level.
  • This represents a fivefold improvement in sensitivity over the previous limit of $6.6 \times 10^{-27}~e\text{cm}$ set in 2001 by Rosenberry and Chupp.
  • The statistical uncertainty was reduced to $6.6 \times 10^{-28}~e\text{cm}$, with systematic uncertainty estimated at $2.0 \times 10^{-28}~e\text{cm}$.
  • The study confirmed that $\vec{E} \times \vec{v}$ geometric phase effects are suppressed due to short collision times relative to precession periods, validating the measurement model.
  • Correlations between EDM and parameters like $T_2^*$ and comagnetometer drift rate were investigated and corrected, improving robustness.
  • The results reduce constraints on the low-energy CP-violating parameters $\bar{g}_{\pi}^{0,1}$ and $\bar{\theta}$ by factors of two and five, respectively, and tighten bounds on the QCD axion contribution by a factor of about five compared to prior work.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.