Skip to main content
QUICK REVIEW

[Paper Review] NINEPINS: Nuclei Instance Segmentation with Point Annotations

Ting An Yen, Hung Chun Hsu|arXiv (Cornell University)|Jun 24, 2020
Forensic and Genetic ResearchBiochemistry, Genetics and Molecular Biology14 references6 citations
TL;DR

This paper proposes NINEPINS, a semi-supervised instance segmentation framework for nuclei in histopathology images that trains a modified HoVer-Net model using pseudo-labels generated from sparse point annotations. The method leverages Voronoi diagrams and distance maps to generate robust segmentation masks from points, achieving performance comparable to fully supervised training and showing minimal degradation in downstream classification tasks despite up to 10% drop in segmentation metrics.

ABSTRACT

Deep learning-based methods are gaining traction in digital pathology, with an increasing number of publications and challenges that aim at easing the work of systematically and exhaustively analyzing tissue slides. These methods often achieve very high accuracies, at the cost of requiring large annotated datasets to train. This requirement is especially difficult to fulfill in the medical field, where expert knowledge is essential. In this paper we focus on nuclei segmentation, which generally requires experienced pathologists to annotate the nuclear areas in gigapixel histological images. We propose an algorithm for instance segmentation that uses pseudo-label segmentations generated automatically from point annotations, as a method to reduce the burden for pathologists. With the generated segmentation masks, the proposed method trains a modified version of HoVer-Net model to achieve instance segmentation. Experimental results show that the proposed method is robust to inaccuracies in point annotations and comparison with Hover-Net trained with fully annotated instance masks shows that a degradation in segmentation performance does not always imply a degradation in higher order tasks such as tissue classification.

Motivation & Objective

  • To reduce the annotation burden in digital pathology by enabling nuclei instance segmentation with only point annotations instead of full mask annotations.
  • To develop a semi-supervised learning framework that generates high-quality pseudo-segmentation masks from sparse point labels.
  • To evaluate the robustness of the method to inaccuracies in point annotations, particularly shifts from true nuclear centroids.
  • To assess the impact of using point-annotation-based segmentation on higher-order tasks such as tissue classification.
  • To demonstrate that performance degradation in instance segmentation does not necessarily translate to degradation in downstream diagnostic tasks.

Proposed method

  • The method generates pseudo-segmentation masks from point annotations using Voronoi diagrams to assign regions to each point, ensuring spatial coverage.
  • Distance map labels are synthesized from the Voronoi regions using the minimum distance from each pixel to the nuclear boundary, enabling training of the distance map branch in HoVer-Net.
  • A modified HoVer-Net architecture is trained using a combination of real instance masks and pseudo-labeled masks generated from point annotations.
  • Point perturbations are applied with Gaussian noise (equations 3 and 4) to simulate annotation inaccuracies and test robustness.
  • The framework uses a two-branch decoder: one for instance segmentation masks and one for distance maps, both trained with cross-entropy and L1 loss respectively.
  • The method evaluates performance using DICE and DQ_point metrics, and assesses downstream classification via CGC-Net on Camelyon16.

Experimental results

Research questions

  • RQ1Can instance segmentation performance be maintained when training with pseudo-labels generated from only point annotations?
  • RQ2How robust is the method to inaccuracies in point annotations, such as shifts from true nuclear centroids?
  • RQ3Does a degradation in segmentation metrics (e.g., DICE or DQ_point) due to weak supervision lead to proportional degradation in higher-order tasks like tissue classification?
  • RQ4Can a semi-supervised framework using point annotations achieve comparable performance to fully supervised training with mask annotations?
  • RQ5To what extent can the use of point annotations reduce annotation burden without compromising diagnostic utility?

Key findings

  • The proposed method maintains stable DICE scores across varying levels of point annotation noise, with minimal degradation even when points are shifted up to ε = 1 from their true centroids.
  • The DQ_point metric, which measures instance-level detection accuracy, shows only a small drop (within ±0.03) when point annotations are perturbed within a reasonable range (ε ≤ 1).
  • Despite a potential 10% drop in segmentation metrics (DICE or DQ_point), the downstream tissue classification task using CGC-Net achieved higher average accuracy (91.60% ± 1.85%) with NINEPINS compared to HoVer-Net (93.51% ± 3.90%) on the Camelyon16 dataset.
  • In fold 1, NINEPINS outperformed HoVer-Net in classification accuracy (94.20% vs. 88.15%), indicating that weak supervision can yield better generalization for higher-level tasks.
  • The results suggest that performance degradation in segmentation does not always imply degradation in downstream diagnostic tasks, supporting the viability of weakly supervised methods in clinical pipelines.
  • The method demonstrates that pseudo-label generation from point annotations is robust and effective, enabling high-quality instance segmentation with significantly reduced annotation effort.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.