[Paper Review] Nonconvex optimization for optimum retrieval of the transmission matrix of a multimode fiber
This paper proposes a modified nonconvex optimization approach for fast and accurate retrieval of the complex-valued transmission matrix (TM) of a multimode fiber using intensity-only measurements. By leveraging accelerated gradient descent and adaptive step size, the method achieves optimal focusing efficiency—93.6% of holography-based gold standard—under low sampling rates (e.g., 8), with a full 8685×1024 TM retrieved in just 42.3 seconds on a standard GPU-accelerated system.
Transmission matrix (TM) allows light control through complex media such as multimode fibers (MMFs), gaining great attention in areas like biophotonics over the past decade. The measurement of a complex-valued TM is highly desired as it supports full modulation of the light field, yet demanding as the holographic setup is usually entailed. Efforts have been taken to retrieve a TM directly from intensity measurements with several representative phase retrieval algorithms, which still see limitations like slow or suboptimum recovery, especially under noisy environment. Here, a modified non-convex optimization approach is proposed. Through numerical evaluations, it shows that the nonconvex method offers an optimum efficiency of focusing with less running time or sampling rate. The comparative test under different signal-to-noise levels further indicates its improved robustness for TM retrieval. Experimentally, the optimum retrieval of the TM of a MMF is collectively validated by multiple groups of single-spot and multi-spot focusing demonstrations. Focus scanning on the working plane of the MMF is also conducted where our method achieves 93.6% efficiency of the gold standard holography method when the sampling rate is 8. Based on the recovered TM, image transmission through the MMF with high fidelity can be realized via another phase retrieval. Thanks to parallel operation and GPU acceleration, the nonconvex approach can retrieve an 8685$ imes$1024 TM (sampling rate=8) with 42.3 s on a regular computer. In brief, the proposed method provides optimum efficiency and fast implementation for TM retrieval, which will facilitate wide applications in deep-tissue optical imaging, manipulation and treatment.
Motivation & Objective
- To overcome the limitations of existing phase retrieval algorithms for transmission matrix (TM) retrieval in multimode fibers, particularly slow convergence and suboptimal performance under noise.
- To enable accurate and efficient complex-valued TM retrieval from intensity-only measurements, avoiding the need for holographic setups with reference beams.
- To achieve high focusing efficiency and robustness in noisy environments while minimizing sampling rate and computational time.
- To demonstrate practical applicability through single- and multi-spot focusing, as well as image transmission, in real-world multimode fiber systems.
Proposed method
- Adopts a modified nonconvex optimization framework based on the relaxed averaged alternating reflection (RAF) algorithm, enhanced with a two-step iterative refinement process (RAF 2-1).
- Employs adaptive step size via the Barzilai-Borwein method to accelerate convergence during gradient descent optimization.
- Utilizes advanced optimization solvers—nonlinear conjugate gradient (NCG) and L-BFGS—compared to standard steepest descent for faster convergence per unit time.
- Introduces a two-phase iterative strategy: first estimating the phase from intensity data, then refining the estimate using gradient-based updates.
- Applies GPU acceleration to enable parallel computation, significantly reducing runtime for large-scale TMs (e.g., 8685×1024).
- Uses a normalized error metric defined as $ \| |\mathbf{X}^H \hat{\mathbf{a}}_i| - \mathbf{y}_i \|_2^2 $ to evaluate reconstruction accuracy across iterations.
Experimental results
Research questions
- RQ1Can a nonconvex optimization approach outperform existing convex and non-convex phase retrieval methods in terms of focusing efficiency and convergence speed for TM retrieval?
- RQ2How does the proposed RAF 2-1 algorithm improve upon the original RAF in reconstructing the complex-valued transmission matrix under noisy conditions?
- RQ3What is the optimal balance between computational time and sampling rate for achieving high-fidelity TM retrieval in multimode fibers?
- RQ4To what extent can intensity-only measurements achieve focusing efficiency comparable to holography-based gold standard methods?
- RQ5How does the method scale in performance when applied to large-scale TMs (e.g., 8685×1024) on standard hardware with GPU acceleration?
Key findings
- The proposed nonconvex method achieves 93.6% focusing efficiency relative to the gold standard holography method at a sampling rate of 8, significantly outperforming conventional phase retrieval techniques.
- For an 8685×1024 TM, the method retrieves the matrix in only 42.3 seconds using a standard computer with GPU acceleration, demonstrating high computational efficiency.
- RAF 2-1 reduces reconstruction error to below $10^{-4}$ in noiseless conditions, showing superior accuracy compared to the original RAF algorithm.
- The use of NCG as a gradient descent solver leads to the fastest error decline per unit time, outperforming both steepest descent and L-BFGS in terms of convergence speed.
- The method maintains robustness under varying signal-to-noise ratios, with improved performance over existing algorithms like GGS, EKF, and SDP-based methods.
- Experimental validation confirms high-fidelity image transmission through the multimode fiber using the recovered TM, demonstrating practical utility in optical imaging and wavefront shaping.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.