Skip to main content
QUICK REVIEW

[Paper Review] Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity

LUX Collaboration, D. S. Akerib|arXiv (Cornell University)|Oct 12, 2022
Dark Matter and Cosmic PhenomenaPhysics and Astronomy31 references5 citations
TL;DR

This paper presents a precise nuclear recoil calibration at sub-keV energies in the LUX experiment using low-energy xenon data, significantly improving the understanding of light and charge yield in dual-phase xenon time projection chambers. The calibration enables a >7-fold sensitivity enhancement for low-mass WIMP searches below 4 GeV/c², demonstrating the critical role of accurate signal response modeling in dark matter detection at the sub-keV scale.

ABSTRACT

Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the light and charge responses of liquid xenon (LXe) to sub-keV nuclear recoils. Using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator, an in situ calibration was conducted on the LUX detector. We demonstrate direct measurements of light and charge yields down to 0.45 keV and 0.27 keV, respectively, both approaching single quanta production, the physical limit of LXe detectors. These results hold significant implications for the future of dual-phase xenon TPCs in detecting low-mass dark matter via nuclear recoils.

Motivation & Objective

  • To improve the calibration of nuclear recoil signals in the LUX experiment at sub-keV energies, where traditional calibration methods are limited.
  • To reduce systematic uncertainties in light and charge yield measurements for low-energy nuclear recoils, critical for detecting low-mass dark matter candidates.
  • To enable more accurate sensitivity estimates for low-mass WIMP searches by refining the signal response model in dual-phase xenon time projection chambers.
  • To validate the performance of the NEST2.3.11 simulation framework using new experimental data, ensuring consistency with observed yields.
  • To support the design and analysis of future tonne-scale dark matter detectors by establishing a low-threshold calibration baseline.

Proposed method

  • Conducted low-energy nuclear recoil calibration using calibrated neutron sources and low-energy xenon data at 250 V/cm and 400 V/cm electric fields.
  • Measured both scintillation (S1) and ionization (S2) light yields across a range of nuclear recoil energies from 0.45 keV to 1.1 keV.
  • Fitted the data to a modified Lindhard model to extract the quanta yield parameters, including the Fano-like factor and field-dependent gain parameters g₁ and g₂.
  • Compared results with existing models (NEST2.0, NEST2.3.11) and prior measurements (XeNu 2019, DD2013) to validate consistency and identify improvements.
  • Used the calibrated yield model in sensitivity simulations with a 92 kg·year exposure, applying a 3-extracted-electron threshold and two-fold PMT coincidence requirement.
  • Incorporated background-free assumptions and enforced zero WIMP acceptance below 0.45 keV to isolate the impact of improved calibration on sensitivity.

Experimental results

Research questions

  • RQ1How accurately can nuclear recoil light and charge yields be calibrated at sub-keV energies in a dual-phase xenon TPC?
  • RQ2To what extent does improved calibration of signal yields enhance the sensitivity to low-mass WIMP dark matter candidates?
  • RQ3How do the measured yields compare with predictions from the NEST2.3.11 simulation framework and prior models?
  • RQ4What is the impact of systematic uncertainties in gain parameters (g₁, g₂) and Fano-like factors on low-energy signal reconstruction?
  • RQ5What threshold energy is required to achieve optimal sensitivity in future tonne-scale dark matter detectors with sub-keV energy thresholds?

Key findings

  • The study achieved a precise calibration of nuclear recoil light and charge yields at energies as low as 0.45 keV, extending the calibration reach below 1 keV.
  • The measured light yield (L_y) and charge yield (Q_y) at 0.45 keV are consistent with the best-fit Lindhard model, with systematic uncertainties quantified for g₁, g₂, and Fano-like factor.
  • The improved calibration enables a >7-fold increase in sensitivity for WIMP masses below 4 GeV/c² compared to previous LUX analysis with a higher S2 threshold.
  • The sensitivity curve with the new calibration (red) surpasses the original LUX result (blue) and approaches the limits of XENON1T (green) and LUX (2017) at low masses.
  • The analysis confirms that the dominant background at low energies is coherent elastic neutrino-nucleus scattering (CEVNS) from 8B neutrinos, setting a fundamental limit on sensitivity.
  • The results validate the NEST2.3.11 simulation framework when calibrated with the new data, supporting its use in future low-mass WIMP search analyses.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.