D. Adey, Sanjib Kumar Agarwalla|arXiv (Cornell University)|Jul 31, 2013
Muon and positron interactions and applicationsEngineering15 citations
TL;DR

nuSTORM proposes a dedicated neutrino facility at Fermilab using stored 3.8 GeV/c muons to produce intense, well-calibrated beams of electron and muon neutrinos. It enables high-precision measurements of neutrino-nucleus cross sections at the 1% level and offers a 10σ sensitivity to sterile neutrino oscillations, while serving as a prototype for future muon accelerators.

ABSTRACT

The nuSTORM facility has been designed to deliver beams of electron neutrinos and muon neutrinos (and their anti-particles) from the decay of a stored muon beam with a central momentum of 3.8 GeV/c and a momentum acceptance of 10%. The facility is unique in that it will: 1. Allow searches for sterile neutrinos of exquisite sensitivity to be carried out; 2. Serve future long- and short-baseline neutrino-oscillation programs by providing definitive measurements of electron neutrino and muon neutrino scattering cross sections off nuclei with percent-level precision; and 3. Constitutes the crucial first step in the development of muon accelerators as a powerful new technique for particle physics. The document describes the facility in detail and demonstrates its physics capabilities. This document was submitted to the Fermilab Physics Advisory Committee in consideration for Stage I approval.

Motivation & Objective

  • To conduct a definitive search for sterile neutrinos using a precisely calibrated neutrino beam from stored muons.
  • To measure neutrino-nucleus scattering cross sections for νₑ and νₘᵤ with percent-level precision.
  • To serve as a technology test-bed for future muon accelerators by demonstrating 6D ionization cooling and advanced magnet designs.
  • To provide a critical foundation for long- and short-baseline neutrino oscillation programs through precise beam and detector characterization.

Proposed method

  • Utilize a 3.8 GeV/c stored muon beam with 10% momentum acceptance to produce neutrinos via μ⁺/μ⁻ decay in a decay ring.
  • Employ a magnetized iron neutrino detector at 2000 m baseline and a near detector at 20 m to study active-sterile oscillations in both appearance and disappearance channels.
  • Implement a superconducting transmission line (STL) concept to generate large-volume, uniform magnetic fields (up to 0.58 T) for detector magnetization, avoiding large vacuum cryostats.
  • Use 150-turn solenoids made from STL-cable with 7500 m of superconducting cable, cooled by supercritical helium at 4.5–6.0 K, to achieve high field uniformity and mechanical stability.
  • Apply a 40-layer multilayer super-insulation and extruded aluminum thermal shield to minimize heat load and maintain cryogenic operation.
  • Simulate magnetic field performance using iron end-walls (1 m thick) to enhance field uniformity and achieve ~0.58 T average field at 50 kA excitation current.

Experimental results

Research questions

  • RQ1Can nuSTORM exclude the currently allowed parameter space for sterile neutrino oscillations with 10σ significance in the νₑ → νₘᵤ appearance channel?
  • RQ2What is the sensitivity of nuSTORM to νₑ disappearance due to oscillations into sterile states, and can it definitively rule out the observed hints?
  • RQ3Can neutrino-nucleus cross sections for νₑ and νₘᵤ be measured with percent-level precision using a well-calibrated beam?
  • RQ4Is the superconducting transmission line (STL) concept viable for generating large-volume, high-uniformity magnetic fields (up to 0.58 T) in a detector solenoid without a large vacuum cryostat?
  • RQ5Can the STL-based magnet design reduce the dominant cost of conventional superconducting coils while maintaining field quality and thermal stability?

Key findings

  • The nuSTORM beam can exclude the currently allowed parameter space for sterile neutrino oscillations in the νₑ → νₘᵤ appearance channel at a significance of 10σ.
  • In the νₑ disappearance channel, nuSTORM has sufficient statistical power to exclude the entire presently allowed region for sterile neutrino oscillations.
  • Neutrino-nucleus scattering cross sections for νₑ and νₘᵤ can be measured with a precision of approximately 1% using the well-defined beam and detector configuration.
  • The STL-based solenoid design achieves an average magnetic field of 0.58 T at 50 kA excitation, with excellent field uniformity in the xz plane when using 1 m thick iron end-walls.
  • The maximum radial and axial forces on the STL solenoid are 16 kN/m and 40 kN/m, respectively, indicating mechanical feasibility under operational conditions.
  • The estimated cost of the STL is approximately $500 per meter, significantly reducing the cost driver of large vacuum cryostats in conventional superconducting coils.