TL;DR

This study evaluates signal decomposition, feature extraction, and selection techniques for classifying crackle and non-crackle lung sounds using an open-source dataset. It finds that Mel-frequency cepstral coefficients (MFCCs) without decomposition, combined with k-NN classification, achieve the highest accuracy of 84.38%, and feature selection via PCA reduces input features by 97% without performance loss.

ABSTRACT

Lung sounds refer to the sound generated by air moving through the respiratory system. These sounds, as most biomedical signals, are non-linear and non-stationary. A vital part of using the lung sound for disease detection is discrimination between normal lung sound and abnormal lung sound. In this paper, several approaches for classifying between no-crackle and crackle lung sounds are explored. Decomposition methods such as Empirical Mode Decomposition, Ensemble Empirical Mode Decomposition, and Discrete Wavelet Transform are used along with several feature extraction techniques like Principal Component Analysis and Autoencoder, to explore how various classifiers perform for the given task. An open-source dataset downloaded from Kaggle, containing chest auscultation of varying quality is used to determine the results of using the different decomposition and feature extraction combinations. It is found that when higher-order statistical and spectral features along with the Mel-frequency cepstral coefficients are fed to the classier we get the best performance with the kNN classifier giving the best accuracy. Furthermore, it is also demonstrated that using a combination of feature selection methods one can significantly reduce the number of input features without adversely affecting the accuracy of the classifiers.

Motivation & Objective

  • To investigate the effectiveness of signal decomposition, feature extraction, and selection in classifying crackle versus non-crackle lung sounds.
  • To determine whether advanced decomposition methods like EMD, EEMD, and DWT improve classification accuracy over raw signal analysis.
  • To evaluate the impact of various feature extraction techniques (e.g., PCA, autoencoders) and classifiers on performance.
  • To assess whether feature selection can reduce dimensionality without sacrificing classification accuracy.
  • To compare the proposed approach against prior state-of-the-art methods on the same open dataset.

Proposed method

  • Employed Empirical Mode Decomposition (EMD), Ensemble EMD (EEMD), and Discrete Wavelet Transform (DWT) for signal decomposition.
  • Extracted features using Mel-frequency cepstral coefficients (MFCCs), higher-order statistics, spectral features, and PCA.
  • Applied autoencoders for deep feature learning and used k-NN, SVM, and other classifiers for performance comparison.
  • Implemented three feature selection methods: PCA, recursive feature elimination (RFE), and correlation-based feature selection (CFS).
  • Used an open-source Kaggle dataset with varying-quality lung sound recordings from two institutions.
  • Evaluated performance using standard metrics: accuracy, precision, recall, and F1-score across multiple classifier configurations.

Experimental results

Research questions

  • RQ1Does signal decomposition via EMD, EEMD, or DWT enhance the classification of crackle versus non-crackle lung sounds?
  • RQ2Which feature extraction method—MFCCs, statistical features, or deep autoencoders—yields the highest classification accuracy?
  • RQ3Can feature selection reduce the number of input features without degrading classifier performance?
  • RQ4How does the k-NN classifier compare to SVM and other models in terms of accuracy for this specific lung sound classification task?
  • RQ5How does the proposed method compare to prior state-of-the-art approaches on the same dataset?

Key findings

  • The k-NN classifier achieved the highest accuracy of 84.38% when using MFCCs extracted directly from raw lung sound signals without decomposition.
  • Signal decomposition methods like EMD and EEMD did not improve classification performance and were less effective than direct MFCC feature extraction.
  • Feature selection via PCA reduced the number of input features from 980 to 30 while maintaining or slightly improving classification accuracy.
  • The combination of MFCCs and k-NN outperformed previous approaches on the same dataset, including CNN and SVM-based methods from prior works.
  • The performance of the best model (k-NN with MFCCs and PCA) was comparable to models using full feature sets, even after 97% feature reduction.
  • The study demonstrates that the proposed pipeline is robust and transferable to other time-series anomaly detection tasks beyond biomedical signals.