Skip to main content
QUICK REVIEW

[Paper Review] On The Importance of Fundamental Computational Fluid Dynamics Towards a Robust and Reliable Model of Left Atrial Flows: Is There More Than Meets the Eye?

Ehsan Khalili, C'ecile Daversin-Catty|arXiv (Cornell University)|Feb 3, 2023
Atrial Fibrillation Management and OutcomesMedicine5 citations
TL;DR

This study investigates the sensitivity of left atrial hemodynamics to spatial and temporal resolution in patient-specific CFD simulations, revealing that intermediate resolutions can yield up to 55% variability in key hemodynamic indices like OSI and RRT. The authors demonstrate that robust, reliable modeling requires high-resolution meshes (10M elements) and fine temporal discretization (10k time-steps per cycle), as lower resolutions produce unreliable results, especially in the left atrial appendage.

ABSTRACT

Computational fluid dynamics (CFD) studies of left atrial flows have reached a sophisticated level, e.g., revealing plausible relationships between hemodynamics and stresses with atrial fibrillation. However, little focus has been on fundamental fluid modelling of LA flows. The purpose of this study was to investigate the spatiotemporal convergence, along with the differences between high- (HR) versus normal-resolution/accuracy (NR) solution strategies, respectively. CFD simulations on 12 patient-specific left atrial geometries, obtained from computed tomography scans, were performed by using a second-order accurate and space/time centered solver. The convergence studies showed an average variability of around 30\% and 55\% for time averaged wall shear stress (WSS), oscillatory shear index (OSI), relative residence time (RRT), and endothelial cell activation potential (ECAP), even between intermediate spatial and temporal resolutions, in the left atrium (LA) and left atrial appendage (LAA), respectively. The comparison between HR and NR simulations showed good correlation in the LA for WSS, RRT, and ECAP (R^2 > 0.9), but not for OSI (R^2 = 0.63). However, there were poor correlations in the LAA especially for OSI, RRT, and ECAP (R^2 = 0.55, 0.63, and 0.61, respectively), except for WSS (R^2 = 0.81). The errors are comparable to differences previously reported with disease correlations. To robustly predict atrial hemodynamics and stresses, numerical resolutions of 10M elements and 10k time-steps per cycle seem necessary (i.e., one order of magnitude higher than normally used in both space and time). In conclusion, attention to fundamental numerical aspects is essential towards establishing a plausible, robust, and reliable model of LA flows.

Motivation & Objective

  • To assess the impact of spatial and temporal resolution on hemodynamic indices in patient-specific left atrial flows.
  • To evaluate the convergence behavior of key hemodynamic metrics—WSS, OSI, RRT, and ECAP—across varying resolution levels.
  • To determine whether commonly used resolution levels in the literature produce reliable and robust results for clinical correlation.
  • To identify minimum resolution thresholds necessary for accurate prediction of atrial hemodynamics and stress indices.

Proposed method

  • Patient-specific left atrial geometries were reconstructed from 64-slice CT scans of 12 individuals.
  • Second-order accurate, space/time-centered finite volume solver was used for CFD simulations.
  • Convergence studies were performed across multiple spatial and temporal resolution levels, including intermediate and high-resolution (HR) configurations.
  • Hemodynamic indices—time-averaged wall shear stress (WSS), oscillatory shear index (OSI), relative residence time (RRT), and endothelial cell activation potential (ECAP)—were computed and compared.
  • Simulations were run for two cardiac cycles to assess temporal stability, with HR simulations showing transitional flow behavior.
  • A comparison between high-resolution (HR) and normal-resolution (NR) strategies was conducted using correlation coefficients (R²) to assess agreement.

Experimental results

Research questions

  • RQ1How do spatial and temporal resolution affect the convergence of hemodynamic indices in left atrial flow simulations?
  • RQ2To what extent do intermediate-resolution simulations differ from high-resolution solutions in predicting WSS, OSI, RRT, and ECAP?
  • RQ3What is the minimum spatial and temporal resolution required to achieve robust and reliable hemodynamic predictions in patient-specific left atrial models?
  • RQ4How do resolution-dependent errors compare to clinically observed differences in disease correlations?
  • RQ5Does the left atrial appendage (LAA) exhibit greater sensitivity to resolution than the main left atrium?

Key findings

  • Spatiotemporal convergence studies revealed average variability of 30% and 55% in WSS, OSI, RRT, and ECAP between intermediate spatial and temporal resolutions in the left atrium and left atrial appendage, respectively.
  • High-resolution simulations showed strong correlation (R² > 0.9) with normal-resolution results for WSS, RRT, and ECAP in the left atrium, but only moderate correlation (R² = 0.63) for OSI.
  • In the left atrial appendage, correlations were poor for OSI (R² = 0.55), RRT (R² = 0.63), and ECAP (R² = 0.61), with only WSS showing moderate agreement (R² = 0.81).
  • The errors observed due to low resolution were comparable in magnitude to differences reported in clinical studies linking hemodynamic indices to atrial fibrillation and thrombus formation.
  • The study concludes that 10 million mesh elements and 10,000 time-steps per cardiac cycle are necessary for robust and reliable modeling, representing an order of magnitude higher resolution than typically used.
  • The findings underscore that fundamental CFD modeling choices—especially resolution and solver accuracy—must be rigorously addressed to ensure clinical relevance and reproducibility of hemodynamic predictions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.