Skip to main content
QUICK REVIEW

[Paper Review] On the interpretation of manifold ultrafast dynamics in supported graphene

Rustam Gatamov, Andrey Baydin|arXiv (Cornell University)|Aug 2, 2018
Photonic and Optical DevicesEngineering59 references10 citations
TL;DR

This study investigates ultrafast carrier and phonon dynamics in chemical vapor deposition (CVD) graphene on quartz using pump-probe spectroscopy across varying pump fluences. It reveals a counterintuitive order-of-magnitude reduction in the differential transmission decay time constant at intermediate fluence due to competing intra- and inter-band transitions, demonstrating that phenomenological bi-exponential fitting can misattribute relaxation dynamics, while a physics-based model incorporating both transition types yields a more accurate hot optical phonon relaxation time constant that increases with fluence.

ABSTRACT

Understanding the ultrafast carrier dynamics of graphene on a substrate is a fundamental step in the development of graphene based opto-electronic devices. Here, we present ultrafast pump-probe measurements of supported graphene on quartz for a range of pump fluences that enable us to observe both decreased and enhanced probe transmission regimes on a femtosecond timescale. Unexpectedly, at an intermediate pump fluence, an order of magnitude decrease in the relaxation time constant of the differential transmission is observed. By employing a number of different models to interpret our experimental data, we demonstrate the importance of considering both intra- and inter-band contributions to the dynamical optical conductivity in order to extract a more physical relaxation time constant of hot optical phonons.

Motivation & Objective

  • To understand the ultrafast carrier and phonon relaxation dynamics in supported graphene, critical for optoelectronic device design.
  • To resolve discrepancies in reported relaxation time constants arising from the use of phenomenological fitting models.
  • To investigate how the interplay between intra- and inter-band optical transitions affects differential transmission at varying pump fluences.
  • To establish a more physically accurate model for extracting hot optical phonon relaxation times in graphene on substrates.

Proposed method

  • Ultrafast pump-probe spectroscopy in transmission geometry using 120 fs Ti:Sapphire pulses at 800 nm (1.55 eV) on CVD graphene transferred to quartz.
  • Differential transmission signals were measured using a lock-in amplifier with a 4 kHz chopper modulation.
  • Data were fitted to a bi-exponential decay model convoluted with Gaussian pulses to extract fast (τ1) and slow (τ2) decay components.
  • A physics-based model of electron-phonon coupling was developed, solving coupled rate equations for electron and optical phonon temperatures with parameters α, β, γ for electron-phonon and phonon-phonon coupling.
  • The model accounts for both intra-band and inter-band contributions to optical conductivity, with the total differential conductivity derived from the sum of these opposing-sign contributions.
  • Theoretical predictions were compared to experimental data to extract the true hot optical phonon relaxation time τop, which was found to increase with pump fluence.

Experimental results

Research questions

  • RQ1How does the differential transmission response in supported graphene vary across a range of pump fluences, particularly at intermediate fluences?
  • RQ2Why does the differential transmission decay time constant exhibit an unexpected minimum at intermediate fluence, contrary to typical trends?
  • RQ3To what extent do phenomenological bi-exponential fits misrepresent the true relaxation dynamics of hot carriers and phonons in graphene?
  • RQ4How do intra-band and inter-band optical transitions contribute to the total differential conductivity with opposite signs, and what is their net effect on the observed dynamics?
  • RQ5What is the correct physical interpretation of the relaxation time constant when both intra- and inter-band contributions are considered?

Key findings

  • At intermediate pump fluence (21 µJ/cm²), the differential transmission decay time constant decreases by an order of magnitude compared to both lower and higher fluence regimes.
  • The observed minimum in decay time is attributed to the competing contributions of intra- and inter-band transitions, which have opposite signs in the optical conductivity.
  • Phenomenological bi-exponential fitting leads to a misleading trend in the extracted slow decay time constant (τ2), which decreases with increasing fluence, contrary to the physically correct trend.
  • The true hot optical phonon relaxation time τop, extracted from the physics-based model, increases with pump fluence, consistent with theoretical expectations.
  • The study demonstrates that neglecting both intra- and inter-band contributions can lead to incorrect interpretation of ultrafast dynamics in graphene on substrates.
  • The results emphasize the necessity of using a physically grounded model rather than purely empirical fitting when analyzing transient transmission in graphene-based systems.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.