[Paper Review] On the robustness of model-based algorithms for photoacoustic tomography: comparison between time and frequency domains
This study compares time- and frequency-domain model-based photoacoustic tomography (PAT) reconstruction algorithms under uncertainty in sensor positions. Using numerical simulations and experimental validation, it demonstrates that time-domain methods are significantly more robust to modeling errors from inaccurate sensor locations, while frequency-domain methods suffer severe image degradation even at low uncertainty levels (e.g., ∼1%).
For photoacoustic image reconstruction, certain parameters such as sensor positions and speed of sound have a major impact in the reconstruction process and must be carefully determined before data acquisition. Uncertainties in these parameters can lead to errors produced by a modeling mismatch, hindering the reconstruction process and severely affecting the resulting image quality. Therefore, in this work we study how modeling errors arising from uncertainty in sensor locations affect the images obtained by matrix model-based reconstruction algorithms based on time domain and frequency domain models of the photoacoustic problem. The effects on the reconstruction performance with respect to the uncertainty in the knowledge of the sensors location is compared and analyzed both in a qualitative and quantitative fashion for both time and frequency models. Ultimately, our study shows that the frequency domain approach is more sensitive to this kind of modeling errors. These conclusions are supported by numerical experiments and a theoretical sensitivity analysis of the mathematical operator for the direct problem.
Motivation & Objective
- To evaluate the robustness of model-based PAT reconstruction algorithms under uncertainty in sensor positions.
- To compare time-domain and frequency-domain approaches in handling modeling errors due to imprecise sensor location knowledge.
- To assess the impact of sensor position uncertainty on image quality in both simulated and experimental PAT setups.
- To identify which reconstruction framework—time or frequency domain—is more resilient to practical measurement inaccuracies in transducer placement.
Proposed method
- Developed time-domain and frequency-domain matrix model-based reconstruction algorithms for photoacoustic tomography.
- Introduced controlled perturbations to sensor positions in the forward model matrices to simulate uncertainty.
- Performed numerical simulations with synthetic data to analyze image quality degradation under increasing sensor position uncertainty.
- Conducted experimental reconstructions using a pulsed laser PAT system with ∼1% uncertainty in transducer positions.
- Quantified image quality using qualitative visual assessment and quantitative metrics such as PSNR and SSIM.
- Conducted theoretical sensitivity analysis of the forward operator to explain the observed differences in robustness.
Experimental results
Research questions
- RQ1How does uncertainty in sensor positions affect image reconstruction quality in time- and frequency-domain model-based PAT?
- RQ2Which reconstruction framework—time or frequency domain—is more robust to modeling errors from imprecise sensor location knowledge?
- RQ3What is the quantitative impact of sensor position uncertainty on image fidelity in both simulated and experimental PAT reconstructions?
- RQ4Why is the frequency-domain approach more sensitive to sensor location errors than the time-domain approach?
Key findings
- The frequency-domain model-based reconstruction method exhibited significantly worse image quality than the time-domain method under sensor position uncertainty, even at low uncertainty levels (∼1%).
- Time-domain reconstruction maintained high image fidelity and was robust to moderate uncertainties in sensor positions, while frequency-domain reconstructions showed severe artifacts and signal distortion.
- Quantitative analysis revealed that PSNR and SSIM values dropped more sharply in frequency-domain reconstructions as sensor position uncertainty increased.
- Theoretical sensitivity analysis indicated that the frequency-domain operator is more sensitive to perturbations in sensor geometry due to the high-frequency complex exponential components.
- Experimental results confirmed the simulation findings, showing that frequency-domain reconstructions failed to recover meaningful images under real-world sensor placement uncertainty.
- The study suggests that time-domain model-based reconstruction should be preferred in standard pulsed-laser PAT setups where sensor position accuracy is limited.
Read this paper