[Paper Review] On the solution of the polarisation gain terms for VLBI data collected with antennas having Nasmyth or E-W mounts
This paper presents a new calibration framework in AIPS to correct for polarisation gain terms in VLBI data from antennas with Nasmyth and E-W mounts, which introduce mount-dependent differential phase shifts (D-terms) due to feed rotation. The method uses modified Jones matrix formulations and D-term solutions tailored to mount-specific geometry, successfully demonstrated on LBA and GMVA data, enabling accurate polarisation calibration for next-generation geodetic and astrophysical VLBI arrays.
I report on the development of new code to support the Nasmyth and E-W antenna mount types in AIPS which will allow polarisation analysis of observations made using these uncommon antenna configurations. These mount types may become more widely spread as they have several advantages, particularly for geodetic observatories. Multi-band observations, with multiple receivers, can only be fitted into telescopes with Nasmyth feeds. These are the requirements for the new generation of geodetic arrays as discussed in IVS2010. Further more the next generation of antennae will also be required to have very high slew rates, and these can be achieved with the E-W mount. The mount type affects the differential phase between the left and the right hand circular polarisations (LHC and RHC) for different points on the sky. The target antennae for the project was the Yebes 40m telescope, but as that was still under construction the data used as a demonstration was from the Pico Veleta antenna as part of the Global Millimeter VLBI Array (GMVA). For the E-W mount type there are suitable data from the Australian LBA array. I demonstrate the effectiveness of the changes made and that the Nasmyth and E-W corrections can be applied.
Motivation & Objective
- To enable accurate polarisation calibration in VLBI for antennas with non-traditional mounts, particularly Nasmyth and E-W configurations, which are becoming standard in next-generation geodetic arrays.
- To address the challenge that these mounts introduce variable differential phase shifts (D-terms) due to feed rotation during tracking, which distort polarisation measurements.
- To develop and validate a systematic method for solving D-terms using mount-specific Jones matrix formulations and parallactic angle corrections.
- To demonstrate the effectiveness of the new calibration pipeline using real LBA and GMVA data from Hobart and Pico Veleta antennas.
- To ensure compatibility with standard AIPS workflows while extending support for advanced telescope configurations in polarisation-sensitive VLBI observations.
Proposed method
- Formulate the polarisation response using Jones matrices tailored to the optical path and number of reflections in Nasmyth and E-W mount systems.
- Derive D-term solutions based on the mount type, including Cassegrain (type 0), right-handed Nasmyth (type 4), and left-handed Nasmyth (type 5) configurations.
- Implement feed rotation corrections by modeling the time-dependent phase difference between left and right circular polarisations due to mount kinematics.
- Apply corrections to RR/LL phase differences in observed data, using parallactic angle and elevation data to identify and remove spurious phase variations.
- Validate the method using data from the LBA (Hobart, E-W mount) and GMVA (Pico Veleta, Nasmyth) experiments, comparing corrected phase responses to expected flatness.
- Integrate the new code into AIPS with minimal disruption to standard calibration pipelines, ensuring backward compatibility and extensibility.
Experimental results
Research questions
- RQ1How do Nasmyth and E-W mount configurations introduce mount-specific D-terms in VLBI polarisation data due to feed rotation?
- RQ2What is the correct Jones matrix formulation for polarisation response in antennas with odd- or even-numbered mirror reflections in Nasmyth optics?
- RQ3Can the D-term corrections for E-W and Nasmyth mounts be accurately derived and applied using parallactic angle and elevation data?
- RQ4How does the new calibration method improve polarisation flux and position angle recovery compared to standard calibration?
- RQ5What evidence confirms the correctness of the D-term solution for a full Nasmyth system, such as the Yebes 40m telescope?
Key findings
- The D-term correction for the E-W mount at Hobart successfully flattened the RR/LL phase difference over time, confirming accurate feed angle correction and validating the E-W mount code.
- For the Pico Veleta GMVA data, the left-handed Nasmyth correction (type 5) produced a flat phase response, while incorrect corrections (Cascegrain or right-handed) showed increasing slopes, proving the method's accuracy.
- The corrected data showed a flat phase response across all antennas, with the calibrator (J0637-752) exhibiting near-zero phase difference after correction, indicating successful removal of feed rotation effects.
- The polarisation position angle and fraction from the LBA experiment V182A showed excellent agreement with ATCA data, particularly in resolving blended components in the velocity range -35 to -36 km/s, where VLBI outperformed ATCA in polarised flux recovery.
- The demonstration on Pico Veleta, despite lacking amplitude calibration, confirmed the correctness of the Nasmyth feed angle model, as only the left-handed Nasmyth correction yielded a flat phase response.
- The full calibration pipeline, including D-term solutions for multiple mount types, was successfully demonstrated and integrated into AIPS, enabling future polarisation calibration for next-generation geodetic and astrophysical VLBI arrays.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.