[Paper Review] Operational experience and evolution of the ATLAS Tile Hadronic Calorimeter Read-Out Drivers
This paper details the operational evolution and hardware/firmware upgrades of the ATLAS Tile Calorimeter Read-Out Drivers (RODs) from LHC Run 1 to Run 2, focusing on real-time signal processing, data compression, and synchronization. The RODs, based on 9U VME boards with DSP-based processing, were upgraded to handle increased luminosity and trigger rates, achieving 94% data-taking efficiency and sub-0.4% data quality loss in Run 2 through optimized Optimal Filtering and enhanced system bandwidth.
TileCal is the central hadronic calorimeter of the ATLAS experiment at the Large Hadron Collider (LHC). It is a sampling detector where scintillating tiles are embedded in steel absorber plates. The tiles are grouped forming cells, which are read-out on both sides by photomultiplier tubes (PMTs). The PMT digital samples are transmitted to the Read-Out Drivers (ROD) located in the back-end system for the events accepted by the Level 1 trigger system. The ROD is the core element of the back-end electronics and it represents the interface between the front-end electronics and the ATLAS overall Data AcQuisition (DAQ) system. It is responsible for energy and time reconstruction, trigger and data synchronization, busy handling, data integrity checking and lossless data compression. The TileCal ROD is a standard 9U VME board equipped with DSP based Processing Units mezzanine cards. A total of 32 ROD modules are required to read-out the entire TileCal detector. Each ROD module has to process the data from up to 360 PMTs in real time in less than 10 microseconds. The commissioning of the RODs was completed in 2008 before the first LHC collisions. Since then, several hardware and firmware updates have been implemented to accommodate the RODs to the evolving ATLAS Trigger and DAQ conditions adjusted to follow the LHC parameters. The initial ROD system, the different updates implemented and the operational experience during the LHC Run 1 and Run 2 are presented.
Motivation & Objective
- To maintain high data-taking and data quality efficiency in the ATLAS Tile Calorimeter under increasing LHC luminosity and trigger rates.
- To address the challenge of signal pileup and noise distortion in PMT pulse reconstruction under evolving LHC conditions.
- To upgrade the ROD system’s processing power and output bandwidth to support higher instantaneous luminosity in Run 2.
- To eliminate negative energy reconstructions in the Optimal Filtering algorithm caused by out-of-time pileup.
- To prepare the ROD system for seamless operation in Run 3 and the High-Luminosity LHC era with minimal modifications.
Proposed method
- RODs use DSP-based Processing Units on 9U VME boards to perform real-time energy and time reconstruction of PMT signals from 360 channels within 10 µs.
- The Optimal Filtering (OF) method computes pulse amplitude and phase via linear combinations of digitized samples using precomputed weights derived from known pulse shapes, noise models, and pileup conditions.
- Two OF variants are used: OF1 subtracts pedestal before filtering, while OF2 enforces zero-sum weights to cancel common-mode noise, though it risks negative energy outputs.
- An iterative OF variant improves performance in non-synchronous trigger conditions, such as cosmic ray runs.
- The system employs elastic buffers with configurable depth and a busy veto signal to prevent buffer overflow and data loss.
- Data integrity is ensured via on-board checks, and lossless compression is applied before transmission via High-speed Optical Link for ATLAS (HOLA) cards.
Experimental results
Research questions
- RQ1How can the ROD system maintain real-time processing performance under increasing LHC luminosity and trigger rates during Run 1 and Run 2?
- RQ2What are the key limitations of the OF2 filtering method under high pileup conditions, and how can they be mitigated?
- RQ3How do hardware and firmware upgrades to the ROD system improve data-taking efficiency and data quality under high occupancy?
- RQ4What role does dynamic, cell-specific OF weight calibration play in maintaining reconstruction accuracy across varying detector conditions?
- RQ5To what extent can the current ROD architecture support the demands of the High-Luminosity LHC (HL-LHC) without major redesign?
Key findings
- The ROD system successfully operated during LHC Run 1 with a data-taking efficiency of approximately 95%, primarily limited by front-end power supply failures.
- Data quality efficiency for TileCal in Run 1 reached 98.7%, demonstrating robust signal reconstruction and integrity checks.
- During Run 2, the upgraded ROD system achieved 94% overall data-taking efficiency and less than 0.4% data quality loss, despite peak luminosity at 2× nominal.
- The replacement of OF2 with OF1 eliminated negative energy reconstructions caused by out-of-time pileup, improving stability for high-level trigger algorithms.
- The introduction of cell-specific OF weights, accounting for position-dependent pileup noise, significantly improved reconstruction accuracy under high-occupancy conditions.
- The ROD system was successfully upgraded with dual Processing Units and dual HOLA cards per module, doubling processing power and output bandwidth to meet Run 2 demands.
Read this paper