Skip to main content
QUICK REVIEW

[Paper Review] Optical funnel to guide and focus virus particles for X-ray laser imaging

Salah Awel, Sebastian Lavin-Varela|arXiv (Cornell University)|Jan 1, 2021
Photodynamic Therapy Research StudiesMedicine1 citations
TL;DR

This paper proposes an optical funnel using a low-divergence hollow-core first-order Bessel beam to guide and focus virus particles in a low-pressure environment, leveraging photophoretic forces for enhanced delivery efficiency. The method experimentally demonstrates a threefold transverse compression of a high-speed aerosolized virus beam, significantly improving particle density for X-ray free-electron laser (XFEL) imaging applications.

ABSTRACT

The need for precise manipulation of nanoparticles in gaseous or near-vacuum environments is encountered in many studies that include aerosol morphology, nanodroplet physics, nanoscale optomechanics, and biomolecular physics. Photophoretic forces, whereby momentum exchange between a particle and surrounding gas is induced with optical light, were recently shown to be a robust means of trapping and manipulating nanoparticles in air. We previously proposed a photophoretic 'optical funnel' concept for the delivery of bioparticles to the focus of an x-ray free-electron laser (XFEL) beam for femtosecond x-ray diffractive imaging. Here, we describe the formation of a high-aspect-ratio optical funnel and provide a first experimental demonstration of this concept by transversely compressing and concentrating a high-speed beam of aerosolized viruses by a factor of three in a low-pressure environment. These results pave the way toward improved sample delivery efficiency for XFEL imaging experiments as well as other forms of imaging and spectroscopy.

Motivation & Objective

  • To address the low efficiency of current sample delivery systems in single-particle imaging (SPI) at X-ray free-electron lasers (XFELs), where less than 0.1% of X-ray pulses intercept particles.
  • To develop a method for increasing the density and precision of nanoparticle beams in vacuum or low-pressure environments using optical forces.
  • To experimentally validate the feasibility of an optical funnel based on photophoretic forces for guiding and concentrating high-speed aerosolized viruses.
  • To enable improved data collection rates and atomic-resolution imaging in SPI by enhancing particle delivery to the XFEL beam focus.

Proposed method

  • The optical funnel is formed using a first-order Laguerre-Gaussian vortex beam with topological charge l = 1, generated via a spiral phase plate and axicon lens.
  • The beam is re-imaged through a de-magnifying collimator to extend the interaction length and create a high-aspect-ratio funnel with a continuously varying beam diameter along the z-axis.
  • Photophoretic forces are induced by counter-propagating the laser beam against the particle beam, slowing particles and pushing them toward the beam axis via momentum transfer with surrounding gas molecules.
  • High-speed stroboscopic imaging at 5 kHz captures particle trajectories, enabling analysis of beam compression and velocity changes.
  • Rayleigh scattering from particles and air is used to map the optical funnel's position and intensity profile with sub-micrometer resolution.
  • Fourier optics simulations are used to model and optimize the beam profile and interaction geometry for particle guiding.

Experimental results

Research questions

  • RQ1Can a photophoretic optical funnel effectively compress and guide high-speed aerosolized virus particles in a low-pressure environment?
  • RQ2To what extent does the use of a Bessel beam with extended interaction length improve particle focusing compared to Gaussian beams?
  • RQ3How do photophoretic forces alter particle velocity and transverse distribution in the presence of a counter-propagating laser beam?
  • RQ4Can the focal position and intensity profile of the optical funnel be accurately mapped using scattered light from particles or air?
  • RQ5What is the maximum achievable beam compression factor using this optical funnel configuration?

Key findings

  • The optical funnel achieved a threefold transverse compression of a high-speed beam of aerosolized granulovirus particles in a low-pressure environment (0.4–1 mbar).
  • The particle beam was focused from an initial diameter of approximately 100 µm to a full width at half maximum of about 33 µm, indicating effective concentration.
  • The optical funnel induced a measurable deceleration of particles, with axial velocity reduction of up to 810 s⁻¹ per watt of laser power, confirming strong photophoretic forces.
  • The focal plane of the optical funnel was mapped with sub-micrometer resolution using Rayleigh scattering from particles and air, enabling precise alignment and calibration.
  • The system demonstrated stable operation at 1.5 mbar chamber pressure with particle beam velocities of 17.4 ± 0.93 m/s under laser-off conditions.
  • The method achieved a significant improvement in particle delivery efficiency, reducing the data collection time required for a full atomic-resolution dataset by orders of magnitude.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.