[Paper Review] Optically detected magnetic resonance of nitrogen vacancies in a diamond anvil cell using designer diamond anvils
This study demonstrates optically detected magnetic resonance (ODMR) of nitrogen-vacancy (NV⁻) centers in microdiamonds within a diamond anvil cell (DAC) using designer diamond anvils with lithographically fabricated metallic microchannels as integrated microwave antennas. The method enables all-optical high-pressure magnetometry with suppressed heating and no need for non-conducting gaskets, achieving a linear pressure dependence of the zero-field splitting parameter D with a slope of 11.72 ± 0.68 MHz/GPa, validating ab initio predictions and enabling NV-based manometry.
Optically detected magnetic resonance of nitrogen vacancy centers in diamond offers novel routes to both DC and AC magnetometry in diamond anvil cells under high pressures ($>3$ GPa). However, a serious challenge to realizing experiments has been the insertion of microwave radiation in to the sample space without screening by the gasket material. We utilize designer anvils with lithographically-deposited metallic microchannels on the diamond culet as a microwave antenna. We detected the spin resonance of an ensemble of microdiamonds under pressure, and measure the pressure dependence of the zero field splitting parameters. These experiments enable the possibility for all-optical magnetic resonance experiments on sub-$μ$L sample volumes at high pressures.
Motivation & Objective
- To overcome the challenge of microwave coupling in high-pressure diamond anvil cells (DACs) where conventional inductive coils are impractical due to limited sample volume and gasket constraints.
- To develop a method for optically detected magnetic resonance (ODMR) of NV⁻ centers in microdiamonds under high pressure (up to 8 GPa) without relying on non-conducting gasket materials.
- To enable all-optical, high-sensitivity magnetometry in sub-μL sample volumes at extreme pressures using integrated microwave antennas on diamond anvils.
- To measure the pressure dependence of zero-field splitting (ZFS) parameters D and E in NV⁻ centers for potential use as a pressure manometer.
Proposed method
- Designer diamond anvils with lithographically deposited 5 μm-wide concentric metallic microchannels on the culet surface serve as integrated microwave antennas for ODMR excitation.
- A diamond anvil cell (DAC) with 1 mm culet diameter and MP35N steel housing was used, with pressure applied via 4-40 bolts and measured via ruby fluorescence.
- Optical detection of NV⁻ center spin states was performed using a confocal microscope and HR4000 spectrometer, with microwave frequency scanned to detect resonant transitions.
- The spin Hamiltonian H = D(Ŝ_z² - S(S+1)/3) + E(Ŝ_x² - Ŝ_y²) was used to model the zero-field splitting, with D and E extracted from Lorentzian fits to ODMR spectra.
- Microdiamonds (1–10 μm) were used as the NV⁻-containing sample, with fluorescence intensity monitored as a function of microwave frequency and pressure.
- Pressure calibration was performed using ruby fluorescence, and the pressure medium (Daphne 7373) was monitored for solidification effects.
Experimental results
Research questions
- RQ1Can integrated microwave antennas on diamond anvils enable ODMR of NV⁻ centers in high-pressure DACs without gasket-related signal degradation?
- RQ2What is the pressure dependence of the zero-field splitting parameter D in NV⁻ centers in microdiamonds under high pressure?
- RQ3Does the strain parameter E exhibit measurable variation with pressure, indicating changes in local symmetry or strain fields?
- RQ4Can the ODMR response of NV⁻ centers serve as a reliable manometer in high-pressure experiments, replacing ruby fluorescence?
- RQ5What is the impact of sample environment (e.g., pressure medium solidification) on NV⁻ linewidth and spectral features?
Key findings
- The zero-field splitting parameter D increases linearly with pressure at a rate of 11.72 ± 0.68 MHz/GPa, consistent with ab initio calculations and lower than previously reported values for type IIa diamonds.
- The strain parameter E shows no significant variation with pressure, suggesting minimal change in local symmetry around NV⁻ centers under compression.
- Linewidth broadening increases with pressure at a rate of 0.8 MHz/GPa, indicating non-hydrostatic stress conditions with a pressure variation of δP/P ≈ 6%.
- The onset of linewidth broadening coincides with the expected solidification of the Daphne 7373 pressure medium at ~2.2 GPa, suggesting strain inhomogeneity develops upon phase transition.
- Relative intensities of the NV⁻ doublet change with pressure, indicating the development of inhomogeneous strain fields as the pressure medium solidifies.
- Single microdiamond ODMR was observed, enabling potential for vector magnetometry and surface nuclear spin detection at high pressure.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.