Skip to main content
QUICK REVIEW

[Paper Review] Optimal Estimation of Capacity and Location of Wind, Solar and Fuel Cell Sources in Distribution Systems Considering Load Changes by Lightning Search Algorithm

Hassan Shokouhandeh, MahmoodReza Ghaharpour|arXiv (Cornell University)|Mar 9, 2020
Optimal Power Flow DistributionEngineering13 references4 citations
TL;DR

This paper proposes an optimal placement and sizing of wind, solar, and fuel cell distributed generators (DGs) in radial distribution systems using the Lightning Search Algorithm (LSA) to minimize power losses and improve voltage profiles under dynamic load conditions. Results on the IEEE 33-bus system show that considering load growth significantly impacts DG planning, and LSA effectively reduces the objective function in both constant and growing load scenarios.

ABSTRACT

In this paper, estimation of optimal capacity and location of installation of wind, solar and fuel cell sources in distribution systems to reduce loss and improve voltage profile, by considering load changes, is carried out with Lightning Search Algorithm (LSA). Studies have been conducted on the standard IEEE 33 bus power system in two scenarios. In the first scenario, study is done with the assumption that the load remains constant throughout the project period and in the second scenario with the load growth. The results of the simulation, indicated that the puissance of load changes on distributed generations (DGs) placement studies. Also, the results confirm the performance of the proposed algorithm in reducing the objective function.

Motivation & Objective

  • To determine the optimal capacity and location of wind, solar, and fuel cell DGs in distribution systems.
  • To account for load growth over time in DG planning, improving system reliability and efficiency.
  • To apply the Lightning Search Algorithm (LSA) for solving the multi-objective optimization problem of DG allocation.
  • To minimize active power losses and enhance voltage profile in radial distribution networks.
  • To validate the effectiveness of LSA in handling dynamic load conditions compared to static assumptions.

Proposed method

  • The Lightning Search Algorithm (LSA) is employed to solve the mixed-integer nonlinear programming problem for DG allocation.
  • LSA simulates the behavior of lightning strikes, using a balance between exploration and exploitation to locate optimal solutions.
  • The objective function combines active power loss minimization and voltage profile improvement, weighted appropriately.
  • Two scenarios are simulated: one with constant load and another with time-varying load growth over the project period.
  • The IEEE 33-bus radial distribution system is used as the test system for validation.
  • Simulation results are analyzed using power flow analysis and performance metrics such as loss reduction and voltage regulation.

Experimental results

Research questions

  • RQ1How does load growth over time affect the optimal placement and sizing of distributed generators in distribution systems?
  • RQ2To what extent does the Lightning Search Algorithm improve loss reduction and voltage profile compared to conventional methods?
  • RQ3What is the impact of integrating wind, solar, and fuel cell sources on system performance under varying load conditions?
  • RQ4How does the LSA algorithm compare in convergence speed and solution quality for DG allocation problems?
  • RQ5Can the proposed method effectively handle the nonlinearity and complexity of multi-source DG integration in radial distribution networks?

Key findings

  • The inclusion of load growth in the planning process significantly alters the optimal placement and capacity of distributed generators compared to constant load assumptions.
  • The Lightning Search Algorithm successfully reduced active power losses in both constant and growing load scenarios, demonstrating robustness.
  • Voltage profile improvement was more pronounced in the load growth scenario, indicating better system stability under dynamic conditions.
  • The algorithm achieved a lower objective function value in the load-growth scenario, confirming its effectiveness in real-world planning contexts.
  • The results show that DG placement is highly sensitive to load variation, and static load assumptions may lead to suboptimal or inefficient designs.
  • The LSA method outperformed traditional optimization techniques in convergence speed and solution quality for the given test system.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.