Skip to main content
QUICK REVIEW

[Paper Review] Performance of a small size telescope (SST-1M) camera for gamma-ray astronomy with the Cherenkov Telescope Array

I. Al Samarai, Cyril Martin Alispach|arXiv (Cornell University)|Jan 1, 2017
Astrophysics and Cosmic PhenomenaPhysics and Astronomy3 citations
TL;DR

This paper presents the performance validation of the SST-1M camera, a small-size telescope camera for the Cherenkov Telescope Array (CTA), using a dedicated test setup (CTS). The camera, based on silicon photomultipliers (SiPMs) with a fully digital trigger and readout system (Digicam), achieves stable operation with a mean dark count rate of 2.05±0.2 MHz/pixel, optical crosstalk of 8%, and time resolution of 176 ps. It meets CTA’s trigger rate and efficiency requirements across varying night-sky background levels, with simulations matching data within 3% across NSB conditions from 3 to 660 MHz/pixel.

ABSTRACT

The foreseen implementations of the Small Size Telescopes (SST) in CTA will provide unique insights into the highest energy gamma rays offering fundamental means to discover and under- stand the sources populating the Galaxy and our local neighborhood. Aiming at such a goal, the SST-1M is one of the three different implementations that are being prototyped and tested for CTA. SST-1M is a Davies-Cotton single mirror telescope equipped with a unique camera technology based on SiPMs with demonstrated advantages over classical photomultipliers in terms of duty-cycle. In this contribution, we describe the telescope components, the camera, and the trigger and readout system. The results of the commissioning of the camera using a dedicated test setup are then presented. The performances of the camera first prototype in terms of expected trigger rates and trigger efficiencies for different night-sky background conditions are presented, and the camera response is compared to end-to-end simulations.

Motivation & Objective

  • To validate the performance of the SST-1M camera prototype for the Cherenkov Telescope Array (CTA), focusing on key parameters such as dark count rate, crosstalk, and timing resolution.
  • To demonstrate that the SiPM-based camera system meets the stringent requirements of CTA for high-energy gamma-ray detection, particularly in terms of trigger efficiency and stability under varying night-sky background (NSB) conditions.
  • To calibrate and commission the camera using a dedicated test setup (CTS) that emulates Cherenkov shower signals and NSB, enabling accurate characterization of response and dynamic behavior.
  • To compare real commissioning data with end-to-end simulations to validate the camera's performance model and ensure reliable signal reconstruction and trigger decisions.
  • To confirm that the camera’s trigger system maintains high efficiency (up to 100%) at low signal levels (1.4 PE/pixel in dark conditions) while suppressing noise and background, even under high NSB (660 MHz/pixel).

Proposed method

  • The SST-1M camera uses a hexagonal Photo-Detection Plane (PDP) with 1296 SiPM pixels grouped into 108 modules, each with a preamplifier and slow control board (SCB) for temperature-stabilized bias voltage control.
  • A fully digital readout and trigger system (Digicam) digitizes signals at 250 MHz with 12-bit FADCs, processes data via FPGA, and uses a 10 Gbps fiber link to transmit full-resolution data upon trigger decision.
  • The camera is commissioned using a Custom Test Setup (CTS) with pulsed (AC) and continuous (DC) LEDs to simulate gamma-ray shower signals and night-sky background (NSB) across the camera.
  • Calibration is performed via single photo-electron (SPE) and multi-photo-electron (MPE) spectra in dark and light conditions, extracting gain (5.6 LSB/PE), dark count rate, and crosstalk probability.
  • Timing resolution is measured by flashing 21 neighboring pixels simultaneously and fitting pulse templates to reconstruct photon arrival times with sub-ns precision.
  • Trigger commissioning involves injecting light into clusters of pixels, varying thresholds, and measuring trigger rates and efficiencies across different NSB levels to validate performance and stability.

Experimental results

Research questions

  • RQ1What is the dark count rate and optical crosstalk of the SiPM-based SST-1M camera under controlled conditions?
  • RQ2How stable is the camera’s time resolution and signal synchronization across its 1296 pixels under varying temperature and signal injection?
  • RQ3What is the trigger efficiency of the SST-1M camera across a range of night-sky background (NSB) levels, and how does it compare to simulation predictions?
  • RQ4To what extent do the measured trigger rates and bias curves match those predicted by independent end-to-end simulations?
  • RQ5Can the camera maintain a stable trigger rate of 500 Hz under high NSB conditions (e.g., 660 MHz/pixel), and what signal threshold is required to achieve this?

Key findings

  • The mean dark count rate of the SST-1M camera is measured at 2.05±0.2 MHz per pixel, with an optical crosstalk probability of 8%, confirming stable SiPM operation under dark conditions.
  • The camera achieves a relative time resolution of 0.25 ns (176 ps absolute) across 21 neighboring pixels, indicating negligible signal path delays and excellent synchronization.
  • The camera maintains a trigger rate of 500 Hz at a signal threshold of 30 PE in a cluster under dark conditions (~40 MHz/pixel NSB), corresponding to 1.4 PE/pixel on average.
  • The trigger efficiency reaches 100% at 1.4 PE/pixel in dark conditions, and remains stable at 3 PE/pixel average across NSB levels from 3 to 660 MHz/pixel, with variation below 2.14 PE/pixel.
  • Simulations based on independent pipelines (toy Monte Carlo and CARE) reproduce the measured ADC distributions and bias curves with agreement within 3% across all NSB levels tested.
  • The measured trigger rate vs. threshold curves (bias curves) are in excellent agreement with simulations, validating the entire chain from SiPM response to trigger decision across all tested conditions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.