Skip to main content
QUICK REVIEW

[Paper Review] Performance of Scintillator Counters with Silicon Photomultiplier Readout

Mu2e Collaboration Cosmic Ray Veto Group, A. Artikov|arXiv (Cornell University)|Nov 2, 2015
Radiation Detection and Scintillator TechnologiesPhysics and Astronomy1 references6 citations
TL;DR

This study evaluates scintillator counters with silicon photomultiplier (SiPM) readout for the Mu2e cosmic ray veto system, using 120 GeV protons at Fermilab. It demonstrates uniform transverse response across the counter width, consistent longitudinal response matching fiber attenuation length, and a 15% higher light yield for 1.8-mm fibers versus 1.4-mm fibers, confirming suitability for high-precision particle detection in high-background environments.

ABSTRACT

The performance of scintillator counters with embedded wavelength-shifting fibers has been measured in the Fermilab Meson Test Beam Facility using 120 GeV protons. The counters were extruded with a titanium dioxide surface coating and two channels for fibers at the Fermilab NICADD facility. Each fiber end is read out by a 2*2 mm^2 silicon photomultiplier. The signals were amplified and digitized by a custom-made front-end electronics board. Combinations of 5*2 cm^2 and 6*2 cm^2 extrusion profiles with 1.4 and 1.8 mm diameter fibers were tested. The design is intended for the cosmic-ray veto detector for the Mu2e experiment at Fermilab. The light yield as a function of the transverse and longitudinal position of the beam will be given.

Motivation & Objective

  • To validate the performance of scintillator counters with wavelength-shifting fibers and SiPM readout for use in the Mu2e cosmic ray veto (CRV) system.
  • To measure the transverse and longitudinal response of counters with varying widths (50 mm, 60 mm) and fiber diameters (1.4 mm, 1.8 mm) under 120 GeV proton beam exposure.
  • To ensure the counters meet the stringent CRV requirement of 99.99% veto efficiency in a high-radiation environment.
  • To assess signal uniformity, edge effects, and the impact of fiber holes and gaps between counters on light yield and detection efficiency.

Proposed method

  • Scintillator counters were extruded with titanium dioxide coating and embedded with wavelength-shifting fibers (Kuraray Y11 non-s type, 175 ppm) of 1.4 mm and 1.8 mm diameter.
  • Each fiber end was read out by a 2×2 mm² Hamamatsu S13360-2050VE SiPM, mounted on carrier boards with spring-loaded pins for mechanical contact.
  • Signals were amplified and digitized using a custom front-end electronics board via HDMI cables, with data collected from both ends of each di-counter.
  • The counters were tested in a 120 GeV proton beam at Fermilab's Meson Test Beam Facility, with beam position and angle varied to map transverse and longitudinal response.
  • Response was measured via pixel count on SiPMs, with corrections for crosstalk under investigation to estimate true photoelectron yield.
  • Monte Carlo simulations were used to model photon absorption by dark-colored fiber guide bars, explaining longitudinal response fall-off at ends.

Experimental results

Research questions

  • RQ1How uniform is the transverse response of scintillator counters with SiPM readout across their width, particularly near edges and at gaps between counters?
  • RQ2How does the longitudinal response of the counters vary along their length, and does it align with the expected fiber attenuation length?
  • RQ3What is the relative light yield difference between 1.4 mm and 1.8 mm diameter wavelength-shifting fibers in the same scintillator extrusion?
  • RQ4To what extent do fiber holes and the 1 mm gap between counters affect signal amplitude and detection uniformity?
  • RQ5How do crosstalk effects in SiPMs influence pixel count, and what is the estimated true photoelectron yield after correction?

Key findings

  • The transverse response is highly uniform across the counter width, with signal dropping below 50% only 0.5 mm from the edge, indicating excellent spatial resolution.
  • A 1 mm effective gap between adjacent counters is clearly visible in the data, with a corresponding dip in signal, confirming mechanical design fidelity.
  • Fiber holes cause a 20–25% dip in signal when the beam passes through them, consistent with reduced path length in the scintillator.
  • The longitudinal response is consistent with the expected fiber attenuation length, with no significant non-uniformities along the length of the extrusion.
  • The 1.8 mm diameter fiber produces approximately 15% higher light yield than the 1.4 mm fiber, though bench tests suggest a larger 40% increase is expected due to misalignment effects.
  • After preliminary crosstalk correction, the estimated photoelectron yield is roughly half the measured pixel yield, indicating significant crosstalk in the current SiPM model.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.