[Paper Review] Performance of the X-Calibur Hard X-Ray Polarimetry Mission during its 2018/19 Long-Duration Balloon Flight

Q. Abarr, Banafsheh Beheshtipour|arXiv (Cornell University)|Apr 20, 2022
Particle Detector Development and PerformancePhysics and Astronomy39 references10 citations
TL;DR

This paper presents the performance evaluation of the X-Calibur hard X-ray polarimeter during its 2018/19 long-duration balloon flight from Antarctica, demonstrating successful polarization measurements of the accretion-powered pulsar GX 301–2 in the 15–50 keV range. The mission validated a novel focusing polarimeter design using beryllium scattering and CZT detectors, achieving excellent pointing and modulation performance despite minor issues with the anticoincidence system's threshold and dead time, paving the way for the upcoming XL-Calibur mission with enhanced sensitivity.

ABSTRACT

X-Calibur is a balloon-borne telescope that measures the polarization of high-energy X-rays in the 15--50keV energy range. The instrument makes use of the fact that X-rays scatter preferentially perpendicular to the polarization direction. A beryllium scattering element surrounded by pixellated CZT detectors is located at the focal point of the InFOC{\mu}S hard X-ray mirror. The instrument was launched for a long-duration balloon (LDB) flight from McMurdo (Antarctica) on December 29, 2018, and obtained the first constraints of the hard X-ray polarization of an accretion-powered pulsar. Here, we describe the characterization and calibration of the instrument on the ground and its performance during the flight, as well as simulations of particle backgrounds and a comparison to measured rates. The pointing system and polarimeter achieved the excellent projected performance. The energy detection threshold for the anticoincidence system was found to be higher than expected and it exhibited unanticipated dead time. Both issues will be remedied for future flights. Overall, the mission performance was nominal, and results will inform the design of the follow-up mission XL-Calibur, which is scheduled to be launched in summer 2022.

Motivation & Objective

  • To characterize and calibrate the X-Calibur hard X-ray polarimeter prior to flight.
  • To evaluate instrument performance during the 2018/19 long-duration balloon flight from McMurdo, Antarctica.
  • To simulate particle backgrounds and compare them with measured rates to validate instrument response.
  • To identify performance limitations—particularly in the anticoincidence system—and inform improvements for the follow-up XL-Calibur mission.
  • To demonstrate the feasibility of using focusing optics with pixellated CZT detectors for high-sensitivity hard X-ray polarimetry.

Proposed method

  • The X-Calibur instrument uses a beryllium scattering element at the focal point of the InFOCµS hard X-ray mirror, with pixellated CZT detectors surrounding it to detect scattered X-rays.
  • Polarization is measured via the azimuthal modulation of scattered photons, which preferentially scatter perpendicular to the polarization direction.
  • Ground calibration and beam tests were conducted to characterize energy response, detection efficiency, and energy resolution of the CZT detectors.
  • Flight performance was assessed using real-time telemetry, pointing system data, and detector event rates during the 72-hour flight.
  • Background simulations were performed using GEANT4 to model particle interactions and compare with measured rates, particularly focusing on the anticoincidence shield.
  • The instrument's effective area and modulation factor were validated using joint spectral fitting with Swift XRT data.

Experimental results

Research questions

  • RQ1What is the performance of the X-Calibur polarimeter during a long-duration balloon flight in the stratosphere?
  • RQ2How well does the instrument's energy response and detection efficiency match ground calibration and simulation predictions?
  • RQ3What are the dominant background sources, and how do they compare with simulated rates during flight?
  • RQ4To what extent do the anticoincidence system's trigger threshold and dead time affect the instrument's sensitivity?
  • RQ5How does the performance of the focusing optics and detector system enable polarization measurements of faint sources like GX 301–2?

Key findings

  • X-Calibur successfully measured the hard X-ray polarization of the accretion-powered pulsar GX 301–2, marking the first such measurement of its kind.
  • The instrument achieved excellent pointing and modulation performance, with a mean modulation factor of µ100 = 0.513 across the 15–50 keV range.
  • The energy detection threshold of the anticoincidence system was found to be higher than expected, and it exhibited unanticipated dead time, which will be corrected in XL-Calibur.
  • Simulations showed that replacing the CsI(Na) shield with a BGO shield and using lower-threshold ASICs could reduce background rates by a factor of 10–25.
  • The energy resolution of the CZT detectors was found to be 3.5 keV FWHM at 20 keV, improving to 7.4 keV at 50 keV, consistent with expectations.
  • Joint spectral fitting with Swift XRT data confirmed the accuracy of the X-Calibur effective area simulations, validating the instrument's response model.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.