[Paper Review] PET-F2I: A Comprehensive Benchmark and Parameter-Efficient Fine-Tuning of LLMs for PET/CT Report Impression Generation
The paper introduces PET-F2I-41K, a large PET/CT impression benchmark, and PET-F2I-7B, a domain-adapted 7B model fine-tuned with LoRA, achieving superior clinical accuracy and privacy-preserving local deployment compared to 27 baselines.
PET/CT imaging is pivotal in oncology and nuclear medicine, yet summarizing complex findings into precise diagnostic impressions is labor-intensive. While LLMs have shown promise in medical text generation, their capability in the highly specialized domain of PET/CT remains underexplored. We introduce PET-F2I-41K (PET Findings-to-Impression Benchmark), a large-scale benchmark for PET/CT impression generation using LLMs, constructed from over 41k real-world reports. Using PET-F2I-41K, we conduct a comprehensive evaluation of 27 models across proprietary frontier LLMs, open-source generalist models, and medical-domain LLMs, and we develop a domain-adapted 7B model (PET-F2I-7B) fine-tuned from Qwen2.5-7B-Instruct via LoRA. Beyond standard NLG metrics (e.g., BLEU-4, ROUGE-L, BERTScore), we propose three clinically grounded metrics - Entity Coverage Rate (ECR), Uncovered Entity Rate (UER), and Factual Consistency Rate (FCR) - to assess diagnostic completeness and factual reliability. Experiments reveal that neither frontier nor medical-domain LLMs perform adequately in zero-shot settings. In contrast, PET-F2I-7B achieves substantial gains (e.g., 0.708 BLEU-4) and a 3.0x improvement in entity coverage over the strongest baseline, while offering advantages in cost, latency, and privacy. Beyond this modeling contribution, PET-F2I-41K establishes a standardized evaluation framework to accelerate the development of reliable and clinically deployable reporting systems for PET/CT.
Motivation & Objective
- Address the lack of clinically rigorous evaluation for PET/CT report impressions.
- Create a large-scale PET/CT impression benchmark (PET-F2I-41K) with clinically grounded metrics.
- Develop a domain-adapted, parameter-efficient model (PET-F2I-7B) for accurate, private PET/CT reporting.
- Provide a standardized evaluation framework to accelerate reliable clinical deployment.
Proposed method
- Construct PET-F2I-41K from 41,191 real-world PET/CT reports (2013–2023) with a strict train/validation/test split.
- Benchmark 27 models across frontier, open-source, and medical-domain LLMs on standard NLG metrics and proposed clinical metrics.
- Define three clinical metrics: Entity Coverage Rate (ECR), Uncovered Entity Rate (UER) and Factual Consistency Rate (FCR) using a greedy longest-match NER against a medical lexicon.
- Fine-tune a domain-adapted 7B model (PET-F2I-7B) from Qwen2.5-7B-Instruct using LoRA (r=64, α=128) for privacy-preserving local inference.
- Evaluate robustness across radiotracers and analyze independence of clinical metrics from lexical NLG metrics.
Experimental results
Research questions
- RQ1Can zero-shot general-purpose LLMs reliably generate PET/CT impressions with complete and factual diagnoses?
- RQ2Do specialized medical LLMs or frontier models outperform domain-adapted, locally deployable models on PET/CT impressions?
- RQ3Do new clinical metrics (ECR, UER, FCR) better capture diagnostic safety and structural formatting than traditional NLG metrics?
- RQ4Does domain-adaptation with LoRA on a compact model yield superior clinical accuracy and privacy without cloud deployment?
Key findings
- PET-F2I-7B achieves state-of-the-art performance across both standard NLG metrics and clinical metrics.
- PET-F2I-7B yields 0.7075 BLEU-4 and 0.8673 ROUGE-L, with 0.8942 METEOR, 0.9103 BERTScore, and 0.9649 SBERT.
- PET-F2I-7B attains 0.8074 ECR and 0.1649 UER, with 0.9420 FCR, indicating high diagnostic completeness, low fabrication, and strong format compliance.
- Domain-adapted 7B model shows 3.0× improvement in exact entity coverage (ECR) over the strongest baseline.
- Zero-shot frontier and medical-domain LLMs exhibit poor clinical completeness and high risk of hallucinations (low ECR, high UER).
- PET-F2I-7B demonstrates robust generalization across minority radiotracers beyond the training distribution.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.