[Paper Review] Piecewise Linearization of Quadratic Branch Flow Limits by Irregular Polygon

Parikshit Pareek, Ashu Verma|arXiv (Cornell University)|Apr 17, 2018
Optimal Power Flow DistributionEngineering4 references20 citations
TL;DR

This paper proposes an irregular polygon-based piecewise linearization method for quadratic branch flow limits in linear optimal power flow (LOPF) formulations. By strategically varying segment angles based on operational characteristics—prioritizing high accuracy near the P-axis and longer segments near the Q-axis—it reduces constraints and computational time without sacrificing solution accuracy, achieving up to 45% time savings in test systems.

ABSTRACT

This letter addresses the issue of linearization of quadratic thermal limits of transmission lines for linear OPF formulation. A new irregular polygon based linearization is proposed. The approach is purely based on geometrical concepts and does not introduce any optimization problem. Comparison of the number of constraints is given with different errors for different branch capabilities and systems. Test case analysis is also presented to validate the irregular polygon linearization strategy with optimal value and computational time results.

Motivation & Objective

  • To address the inefficiency of regular polygon linearization in representing transmission line thermal limits with uniform error.
  • To reduce the number of constraints and computational time in linear OPF formulations without compromising solution accuracy.
  • To develop a geometry-driven method that adapts error distribution based on actual power flow operating conditions.
  • To provide a systematic criterion for selecting polygon segments that reflect operational realities, especially high power factor operation near the P-axis.

Proposed method

  • Proposes an irregular polygon with variable segment angles (Δθn) to achieve non-uniform error distribution, minimizing error near the P-axis.
  • Uses equal Q-axis divisions (∆Q) and calculates ∆θmin from desired minimum error (ем,min) via inverse cosine: ∆θmin = cos⁻¹{2(1 - ем,min/Si)² - 1}.
  • Derives the number of segments per quadrant as m_q = sin⁻¹(∆θmin), leading to total Mi_rr = 4√(1 - φ²), where φ = 1 - (ем,min/Si)².
  • Applies the method by placing line segments such that the maximum error in each segment is bounded by ем,min, ensuring conservative approximation.
  • Replaces the circular thermal limit constraint with a set of linear inequalities corresponding to each polygon side.
  • Introduces a general strategy for hot-start OPF by linearizing around the current operating point using angle-specific segment sizing.

Experimental results

Research questions

  • RQ1Can irregular polygon linearization reduce the number of constraints in LOPF while maintaining solution accuracy compared to regular polygon methods?
  • RQ2Does adaptive error distribution—lower near the P-axis and higher near the Q-axis—improve the speed-accuracy trade-off in LOPF?
  • RQ3What is the optimal number of segments Mi_rr required to achieve a target maximum error ем,min for a given MVA limit?
  • RQ4How does the proposed method affect the optimal objective value and power flow patterns compared to conventional approaches?
  • RQ5To what extent does the method reduce computational time in standard IEEE test systems?

Key findings

  • The irregular polygon method reduces the number of branch constraints by up to 45% compared to regular polygon methods, with 39-Bus system showing 31% fewer constraints at ем,min = 0.1 MVA.
  • For the IEEE-30 bus system, the proposed method achieved 45% time savings at ем,min = 0.1 MVA, with computational time decreasing as accuracy demands increased.
  • The objective value error was within 0.7% across all systems (9-Bus to 118-Bus), with the irregular polygon matching or slightly outperforming the regular polygon in optimality.
  • Normalized power flows under both methods were nearly identical (Fig. 7 and 8), confirming that the proposed method does not distort the power flow pattern.
  • The method maintains model accuracy: objective value errors were consistently below 2.6% across all test systems, with 39-Bus system showing identical 2.53% error for both methods.
  • The approach enables faster LOPF solutions by reducing constraint matrix size, with time savings increasing at higher accuracy levels (e.g., 0.1 MVA error) due to fewer but more strategically placed segments.