Skip to main content
QUICK REVIEW

[Paper Review] Polarisation at HERA - Reanalysis of the HERA II Polarimeter Data -

B. Sobloher, T. Behnke|arXiv (Cornell University)|Jan 13, 2012
Geophysics and Gravity MeasurementsEarth and Planetary Sciences1 references9 citations
TL;DR

This paper presents a final reanalysis of the HERA II polarimeter data, combining longitudinal (LPOL) and transverse (TPOL) polarimeter measurements with refined systematic error treatment. It introduces a robust averaging procedure accounting for correlations and period-dependent uncertainties, yielding a total systematic uncertainty of <1.9% for HERA II polarisation measurements, with LPOL and TPOL scales confirmed independently via rise time measurements.

ABSTRACT

In this technical note we briefly present the analysis of the HERA polarimeters (transversal and longitudinal) as of summer 2011. We present the final reanalysis of the TPOL data, and discuss the systematic uncertainties. A procedure to combine and average LPOL and TPOL data is presented.

Motivation & Objective

  • To re-evaluate systematic uncertainties in the HERA II longitudinal (LPOL) and transverse (TPOL) polarimeters to improve polarisation measurement accuracy.
  • To develop a consistent procedure for combining LPOL and TPOL data, accounting for correlations and period-dependent error sources.
  • To validate the polarisation scale of TPOL independently using rise time measurements from 2007.
  • To provide a standardized recommendation for experiments to use polarisation values in their analyses, with proper error treatment.
  • To ensure reliable polarisation values for HERMES, H1, and ZEUS experiments using the full HERA II dataset.

Proposed method

  • A complete reanalysis of TPOL data was performed, incorporating corrections for laser beam–electron beam interaction region effects and non-vanishing linear light polarisation.
  • Systematic uncertainties in LPOL were re-evaluated using a structured approach, including pedestal calibration via unbinned maximum likelihood fits to delayed and undelayed ADC channels.
  • Pedestal subtraction was performed event-by-event using calibrated offset and slope parameters derived from laser-off events with filled and empty bunches.
  • The polarisation scale for TPOL was independently confirmed using rise time measurements taken at the end of HERA II running, showing good agreement with intrinsic analysis scale.
  • A weighted averaging procedure was developed, combining LPOL and TPOL results using equal luminosity weights per 5-minute bucket, with errors treated as uncorrelated, scale-correlated, and uncorrelated components.
  • Error propagation was formalized using a quadrature sum of uncorrelated, LPOL-scale, and TPOL-scale uncertainties, with sign-dependent correlation for left/right helicity states.

Experimental results

Research questions

  • RQ1What are the dominant systematic uncertainties in the HERA II LPOL and TPOL polarimeters, and how do they vary across different running periods?
  • RQ2How can the results from the two independent polarimeters (LPOL and TPOL) be consistently combined to yield a single, reliable polarisation measurement?
  • RQ3Is the TPOL polarisation scale consistent when validated independently via rise time measurements?
  • RQ4What is the optimal procedure for experiments to apply in their analyses when using HERA II polarisation data, including error treatment and averaging?
  • RQ5How do correlations between polarimeter measurements and period-dependent conditions affect the final uncertainty budget?

Key findings

  • The final systematic uncertainty for LPOL was confirmed at 2.0%, with additional uncertainty of ≤1.2% applied from July 2, 2004, due to calorimeter replacement.
  • The internal systematic uncertainty of the TPOL was found to be 1.9%, accounting for beam–laser interaction region effects and linear light polarisation.
  • Independent rise time measurements confirmed the TPOL polarisation scale with no indication of bias or shift, validating the analysis scale.
  • The combined averaging procedure reduces total systematic uncertainty to <1.9% across all HERA II running periods, with positron runs achieving <1.4%.
  • The total uncertainty for the average polarisation values is calculated by quadrature sum of uncorrelated, LPOL-scale, and TPOL-scale components, with proper sign correlation for left/right helicity states.
  • The recommended procedure ensures consistent error treatment and data combination, with illustrative results in Table 10 showing average polarisation values and uncertainties for four distinct running periods.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.