Skip to main content
QUICK REVIEW

[Paper Review] Production and measuring methods and procedures in precision optical cavities production

Jiří Beneš, František Procháska|arXiv (Cornell University)|Jul 1, 2021
Advanced Frequency and Time StandardsPhysics and Astronomy8 references1 citations
TL;DR

This paper presents a precision manufacturing process for Fabry–Perot laser resonators using ULE glass spacers and fused silica mirrors, achieving 5 arcsec face parallelism and 0.014 mm cylindricality in a 180 mm long cavity. The method integrates custom hollow drilling, stress-relief etching, and 3D coordinate metrology to enable sub-ppm stability at 31 °C, supporting ultra-stable lasers for optical clocks and frequency transfer.

ABSTRACT

This work presents the development of the production process of a Fabry Perot type laser resonator. It describes the acquired knowledge in the field of production of very precise optical standards, cavities, and lenses. In addition, it describes the measurement methods used in production. The work is intended for industry and science.

Motivation & Objective

  • To develop a repeatable, high-precision production process for Fabry–Perot laser resonators with sub-arcsecond angular accuracy.
  • To solve thermal expansion mismatch between fused silica mirrors and ULE spacers through mechanical stabilization using ULE rings.
  • To enable long, precise cavity drilling (180 mm, 12 mm diameter) with minimal deviation and residual stress.
  • To achieve high-accuracy measurement of geometric parameters in ultra-precision optics using 3D coordinate metrology.
  • To design a resonator system stable at 31 °C for applications in optical atomic clocks and phase-coherent fiber links.

Proposed method

  • Used ULE glass (zero thermal expansion at 31 °C) as the spacer material to minimize temperature-induced frequency drift.
  • Employed a custom 300 mm hollow diamond-bonded drill with internal cooling and lever-assisted ejection to prevent breakage during deep-hole drilling.
  • Applied 1:1 HCl/HF etching to relieve subsurface stresses and remove machining residues after roughing.
  • Implemented a 3D coordinate measuring machine (CMM) with a 90 mm probe and 8 mm ball to measure cavity roundness and cylindricality in 10 mm axial steps.
  • Used FEM simulations to optimize mirror stabilization by adding an external ULE ring to suppress axial bending.
  • Conducted thermal cycling to 200 °C to verify joint integrity and mechanical stability of all optical and mechanical interfaces.

Experimental results

Research questions

  • RQ1How can a 180 mm long, 12 mm diameter cavity be drilled with high coaxiality and cylindricality in ULE glass?
  • RQ2What mechanical and thermal design strategies minimize frequency drift in ultra-stable laser resonators?
  • RQ3How can stress and geometric distortion be reduced in fused silica mirrors bonded to ULE spacers?
  • RQ4What measurement techniques ensure sub-arcsecond angular accuracy and 0.014 mm cylindricality in long optical cavities?
  • RQ5How can the resonator be fabricated and tested to ensure vacuum compatibility and long-term stability at 31 °C?

Key findings

  • Achieved 5 arcsec face parallelism and 0.02 mm coaxiality in the 180 mm cavity, meeting stringent requirements for ultra-stable lasers.
  • Demonstrated 0.014 mm cylindricality of the cavity over 180 mm length, critical for mode control and frequency stability.
  • Reduced thermal drift to ~3.2 mHz/s via stabilization at 31 °C, leveraging ULE’s zero-CTE point.
  • Successfully drilled and measured a 180 mm long, 12 mm diameter hole with minimal deviation using a custom hollow drill and laser monitoring.
  • Validated joint integrity through thermal cycling to 200 °C, confirming robustness for vacuum and high-temperature operation.
  • Achieved 0.472 nm RMS micro-roughness on the concave mirror surface, indicating high optical quality.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.