[Paper Review] Proposal for taking data with the KLOE-2 detector at the DA$Φ$NE collider upgraded in energy
This paper proposes upgrading the DAΦNE collider to 2.5 GeV center-of-mass energy to enable high-precision measurements of hadronic cross sections using the KLOE-2 detector. With a luminosity of ~10³² cm⁻²s⁻¹, the upgrade would allow a one-year scan of the 1–2.5 GeV region, reducing uncertainties in the hadronic vacuum polarization contribution to the muon g−2 and αem(MZ²) by a factor of two, crucial for testing the Standard Model and probing new physics.
This document reviews the physics program of the KLOE-2 detector at DA$Φ$NE upgraded in energy and provides a simple solution to run the collider above the $ϕ$-peak (up to 2, possibly 2.5 GeV). It is shown how a precise measurement of the multihadronic cross section in the energy region up to 2 (possibly 2.5) GeV would have a major impact on the tests of the Standard Model through a precise determination of the anomalous magnetic moment of the muon and the effective fine-structure constant at the $M_Z$ scale. With a luminosity of about $10^{32}$cm$^{-2}$s$^{-1}$, DA$Φ$NE upgraded in energy can perform a scan in the region from 1 to 2.5 GeV in one year by collecting an integrated luminosity of 20 pb$^{-1}$ (corresponding to a few days of data taking) for single point, assuming an energy step of 25 MeV. A few years of data taking in this region would provide important tests of QCD and effective theories by $γγ$ physics with open thresholds for pseudo-scalar (like the $η'$), scalar ($f_0,f'_0$, etc...) and axial-vector ($a_1$, etc...) mesons; vector-mesons spectroscopy and baryon form factors; tests of CVC and searches for exotics. In the final part of the document a technical solution for the energy upgrade of DA$Φ$NE is proposed.
Motivation & Objective
- To reduce the theoretical uncertainty in the hadronic vacuum polarization contribution to the muon anomalous magnetic moment (aμHLO) below 3×10⁻¹⁰.
- To improve the precision of the effective fine-structure constant at the Z-boson mass scale, αem(MZ²), by measuring hadronic cross sections in the 1–2.5 GeV energy range.
- To enable high-statistics studies of γγ physics, vector and scalar meson spectroscopy, baryon form factors, and CVC tests via open thresholds for exotic and light mesons.
- To provide a competitive alternative to radiative return at B-factories and VEPP-2000 for precision hadronic measurements in the 1–2.5 GeV region.
- To propose a technically feasible, cost-effective upgrade path for DAΦNE to reach ~2 GeV center-of-mass energy with minimal modifications to existing infrastructure.
Proposed method
- Propose an energy upgrade of the DAΦNE collider to increase beam energy from 700 MeV to ~1.02 GeV (2.04 GeV center-of-mass), enabling data collection up to 2.5 GeV.
- Utilize existing KLOE-2 detector with planned hardware upgrades to achieve high luminosity and precision in e⁺e⁻ annihilation measurements.
- Implement a stepwise energy scan with 25 MeV steps from 1 to 2.5 GeV, collecting ~20 pb⁻¹ per point in a few days, enabling a full scan in ~1 year.
- Maintain high beam lifetime and luminosity by using beam collimation during injection and ramping, and by operating without wigglers to reduce beam loss.
- Replace or modify main dipoles to increase magnetic field strength and allow higher beam energy, with a feasibility study required before final implementation.
- Use a technical solution involving superconducting counter-solenoids and electromagnetic Panovsky-like quadrupoles to manage the detector magnetic field at higher energies.
Experimental results
Research questions
- RQ1Can a modest upgrade of the DAΦNE collider extend its energy reach to 2.5 GeV center-of-mass energy with minimal cost and engineering effort?
- RQ2What is the achievable luminosity and integrated luminosity per day for a stable scan in the 1–2.5 GeV region with KLOE-2?
- RQ3To what extent can precise hadronic cross-section measurements in this energy range reduce uncertainties in aμHLO and αem(MZ²)?
- RQ4How does the effective luminosity of DAΦNE-2 compare to radiative return at B-factories and VEPP-2000 in the 1–2.5 GeV region?
- RQ5What technical solutions can ensure stable beam operation and sufficient luminosity at higher energies without compromising beam lifetime or detector performance?
Key findings
- A one-year data-taking campaign at 1–2.5 GeV with a peak luminosity of ~5×10³² cm⁻²s⁻¹ would yield ~5 pb⁻¹/day, enabling a full energy scan with high statistical precision.
- The projected integrated luminosity of ~5 fb⁻¹ over a few years would reduce the uncertainty in the hadronic vacuum polarization contribution to the muon g−2 by a factor of two.
- The upgrade would reduce the uncertainty in aμHLO to below 3×10⁻¹⁰, meeting the precision target required to test new physics in upcoming FNAL and J-PARC experiments.
- The effective luminosity of DAΦNE-2 in the 1–2.5 GeV region is expected to exceed that of radiative return at B-factories due to the absence of photon emission losses.
- A technical upgrade to the main dipoles is feasible and could enable a beam energy of ~1.02 GeV (2.04 GeV center-of-mass), with a ±10% uncertainty pending detailed engineering studies.
- The cost estimate for the upgrade is expected to remain under 10 MEur, with a timeline of ~1 year for technical design, 1 year for procurement, and 6 months for installation.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.