[Paper Review] Quenching factor measurement for NaI(Tl) scintillation crystal

H. W. Joo, H. S. Park|arXiv (Cornell University)|Sep 27, 2018
Dark Matter and Cosmic PhenomenaPhysics and Astronomy8 citations
TL;DR

This study measures the quenching factor (QF) for NaI(Tl) scintillation crystals using 2.43-MeV mono-energetic neutrons from a deuteron-deuteron fusion reaction. It reports QF values of 10–23% for sodium and 4–6% for iodine recoils at nuclear recoil energies from 9–152 keV (Na) and 19–75 keV (I), with improved precision over prior measurements, providing critical calibration data for direct dark matter searches using NaI(Tl) detectors.

ABSTRACT

Scintillation crystals are commonly used for direct detection of weakly interacting massive particles (WIMPs), which are suitable candidates for a particle dark matter. It is well known that the scintillation light yields are different for electron recoil and nuclear recoil. To calibrate the energies of WIMP-induced nuclear recoil signals, the quenching factor (QF) needs to be measured, which is the light yield ratio of the nuclear recoil to electron recoil. Measurements of the QFs for Na and I recoils in a small (2 cm x 2 cm x 1.5 cm) NaI(Tl) crystal are performed with 2.43-MeV mono-energetic neutrons generated by deuteron-deuteron fusion. Depending on the scattering angle of the neutrons, the energies of the recoiled ions vary in the range of 9 - 152 keV for Na and 19 - 75 keV for I. The QFs of Na are measured at 9 points with values in the range of 10 - 23 % while those of I are measured at 4 points with values in the range of 4 - 6 %.

Motivation & Objective

  • To measure the quenching factor (QF) for Na and I recoils in NaI(Tl) scintillation crystals with high precision for use in direct dark matter detection.
  • To reduce uncertainties in QF values by systematically accounting for detector efficiency corrections, particularly trigger and noise cut thresholds.
  • To provide calibrated QF data for the COSINE-100 experiment, which uses the same target material as the DAMA/LIBRA experiment.
  • To resolve discrepancies in previous QF measurements by employing mono-energetic neutrons and improved energy spectrum analysis.

Proposed method

  • Mono-energetic 2.43-MeV neutrons were produced via deuteron-deuteron fusion in a DD109 neutron generator at KRISS.
  • A 2 cm × 2 cm × 1.5 cm NaI(Tl) crystal was irradiated at 150 cm from the source, with neutron scattering angles varied to produce a range of recoil energies.
  • Scintillation light pulses were detected using a photomultiplier tube, and electron-equivalent energy (Eee) was calibrated using 59.54 keV 241Am gamma sources.
  • Nuclear recoil energy (Enr) was determined via Monte Carlo simulation using the GEANT4 toolkit, accounting for neutron scattering kinematics.
  • Efficiency corrections for trigger and noise cut thresholds were applied using Gaussian fitting parameters (qc, qt), with uncertainties propagated via quadratic sum.
  • The quenching factor was calculated as QF = Eee / Enr, with statistical and systematic uncertainties combined using error propagation.

Experimental results

Research questions

  • RQ1What is the quenching factor for sodium recoils in NaI(Tl) at recoil energies between 9 and 152 keV?
  • RQ2What is the quenching factor for iodine recoils in NaI(Tl) at recoil energies between 19 and 75 keV?
  • RQ3How do efficiency corrections for trigger and noise cuts affect the precision of QF measurements in NaI(Tl) detectors?
  • RQ4How do the measured QF values compare with previous results from radionuclide and neutron generator sources?

Key findings

  • The quenching factor for sodium recoils ranges from 10% to 23% across recoil energies of 9–152 keV, with the lowest value (10%) at 9 keV and the highest (23%) at 152 keV.
  • The quenching factor for iodine recoils ranges from 4% to 6% across recoil energies of 19–75 keV, with values increasing slightly with energy.
  • The measured QF values for both Na and I are consistent with recent high-precision measurements by Collar, Xu et al., and Stiegler et al., but with smaller uncertainties.
  • The study reports a threshold of ~1 keV electron-equivalent energy (corresponding to 9 keV Na recoil), which is relevant for the COSINE experiment's detection threshold.
  • The uncertainty in QF measurements was reduced by systematically accounting for trigger efficiency and noise cut efficiency corrections using Gaussian fitting parameters.
  • The results support the use of NaI(Tl) crystals as a target material in direct dark matter searches, with calibrated QFs enabling accurate nuclear recoil energy reconstruction.